ASTM D6556-2014 red 2081 Standard Test Method for Carbon BlackTotal and External Surface Area by Nitrogen Adsorption《炭黑的标准试验方法 使用氮吸收法测定总面积和外部表面积》.pdf
《ASTM D6556-2014 red 2081 Standard Test Method for Carbon BlackTotal and External Surface Area by Nitrogen Adsorption《炭黑的标准试验方法 使用氮吸收法测定总面积和外部表面积》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6556-2014 red 2081 Standard Test Method for Carbon BlackTotal and External Surface Area by Nitrogen Adsorption《炭黑的标准试验方法 使用氮吸收法测定总面积和外部表面积》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6556 10D6556 14Standard Test Method forCarbon BlackTotal and External Surface Area by NitrogenAdsorption1This standard is issued under the fixed designation D6556; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the total surface area by the Brunauer, Emmett, and Teller (B.E.T.
3、 NSA) theoryof multilayer gas adsorption behavior using multipoint determinations and the external surface area based on the statisticalthickness surface area method.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.3 Thi
4、s standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. (The minimum safety equ
5、ipment should include protective gloves, sturdy eye and face protection).2. Referenced Documents2.1 ASTM Standards:2D1799 Practice for Carbon BlackSampling Packaged ShipmentsD1900 Practice for Carbon BlackSampling Bulk ShipmentsD3765 Test Method for Carbon BlackCTAB (Cetyltrimethylammonium Bromide)
6、Surface Area (Withdrawn 2007)3D4483 Practice for Evaluating Precision for Test Method Standards in the Rubber and Carbon Black Manufacturing Industries3. Summary of Test Method3.1 The total and external surface areas are measured by evaluating the amount of nitrogen adsorbed, at liquid nitrogentempe
7、rature, by a carbon black at several partial pressures of nitrogen. The adsorption data is used to calculate the NSAand STSAvalues.4. Significance and Use4.1 This test method is used to measure the total and external surface area of carbon blacks based on multipoint nitrogenadsorption. The NSA measu
8、rement is based on the B.E.T. theory and it includes the total surface area, inclusive of micropores,pore diameters less than 2 nm (20 ). The external surface area, based on the statistical thickness method (STSA), is defined asthe specific surface area that is accessible to rubber.4.2 CTAB SurfaceA
9、rea (formerly Test Method D3765) has been withdrawn. The CTAB value may be estimated from the STSAvalue using Eq 1. The equation is based on a linear regression of the STSA and CTAB measured values of the SRB 5 standards.CTAB5STSA*1.017012.6434 (1)5. Apparatus5.1 Multipoint Static-Volumetric Gas Ads
10、orption Apparatus, with Dewar flasks and all other accessories required for operation.5.2 Sample Cells, that when attached to the adsorption apparatus, will maintain isolation of the sample from the atmosphereequivalent to a helium leak rate of 1 L)Fill and cover the Dewar for a minimum of 16 h prio
11、r to use, unless continuous Po measurementsare employed. For continuous Po, use a 2-h Dewar equilibration. Once equilibration is reached, a large Dewar can maintain thisequilibration for several days if kept filled and covered. The cleaning frequency is left to the discretion of the operator, but is
12、 notto exceed once per week.9.3 Following is a list of Po measurement options:9.3.1 Continuous Po (measurement at each relative pressure point)This method is considered the best practice; however, itgenerally increases analysis time.9.3.2 Single Po Per AnalysisAlthough this value can be measured bef
13、ore, during, or after the run, a Po value measured at theend of the analysis is preferred, since STSA is calculated from the last data points acquired and is significantly influenced by Povalues. This method requires that a Po value be determined prior to initiating any measurements to ensure equili
14、brium of the Dewaras described in 9.4. Subsequently, a new Po value is measured for each run, which is used for calculating NSA/STSA values.9.3.3 Daily PoThis method is used when evidence of a stable Dewar is present and no changes in atmospheric pressure greaterthan 0.13 kPa (1 mm Hg) occur.9.3.4 C
15、alculated PoThis method calculates a Po value by measuring atmospheric pressure and adding a value between 1.3 and2.6 kPa (10 and 20 mm Hg). The operator is responsible for determining the constant used in their laboratory; however, 2.0 kPa(15 mm Hg) is most commonly used.9.4 With the exception of c
16、ontinuous Po measurements, it is recommended that the Po value be determined prior to initiatingNSA/STSA analyses. A Po value of 1.3 to 2.6 kPa (10 to 20 mm Hg) above atmospheric pressure and two consecutive Po valuesthat differ by no more that 0.13 kPa (1 mm Hg) over a 10-min time period are indica
17、tions of a stable Dewar. Experience will teachthe operator about expected differences in Po and atmospheric pressure in their laboratory.NOTE 4A minimum wait time of 10 min is recommended between Po measurements, as immersing the Po cell into the LN2 disrupts the temperatureequilibration. Po measure
18、ments taken at short intervals will result in erroneously high and unstable values.9.5 Determine the free space of the sample cell by measurement with helium or by calculation using an assumed carbon blackdensity of 1.9 g/cm3.9.6 Obtain a minimum of five data points evenly spaced in the 0.1 to 0.5 r
19、elative pressure (P/Po) range. For some tread carbonblacks, particularly N100 and N200 series, it is necessary to measure two additional data points, 0.05 and 0.075, in order to increasethe accuracy of the NSAmeasurement.Adata point consists of the relative pressure of equilibrium and the total amou
20、nt of nitrogengas adsorbed by the sample at that relative pressure.9.7 Determine the mass of the cell with dry sample to the nearest 0.1 mg. This may be done before or after measuring nitrogenadsorption. Avoid inconsistent use of helium, as a buoyancy error of 1 mg/cm3 of cell volume can occur. As a
21、n alternative, thecarbon black mass may be determined directly by pouring it from the sample cell into a tared weighing pan, taking care to removeall of the carbon black.10. Calculation10.1 Most automated instruments will perform the following computations at the completion of the analysis. The user
22、 mustverify that the internal computations conform to the following method.10.2 Sample Mass:sample mass dried!5mass of cell1sample!2mass of cell! (2)Record masses to nearest 0.1 mg.10.3 Volume of Nitrogen Adsorbed:10.3.1 Calculate total volume of nitrogen adsorbed per gram of sample to the nearest 0
23、.0001 cm3/g as follows:Va 5 Volume of Nitrogen for each dosing in cm3sample mass in g (3)10.4 Nitrogen Surface Area:10.4.1 Determine the nitrogen surface area (NSA) using a B.E.T. plot from the Brunauer, Emmett, and Teller4 equation asfollows:PVa Po 2P! 51VmC1C 21VmC 3PPo (4)4 Brunuaer, Emmett, and
24、Teller, Journal of the American Chemical Society, Vol. 60 , 1938, p. 309.D6556 143where:P = manometer pressure in kPa,Po = saturation vapor pressure of nitrogen in kPa,Vm = volume of nitrogen per gram that covers one monomolecular layer in standard cm3/g, andC = B.E.T. constant. Its numerical value
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD65562014RED2081STANDARDTESTMETHODFORCARBONBLACKTOTALANDEXTERNALSURFACEAREABYNITROGENADSORPTION 炭黑

链接地址:http://www.mydoc123.com/p-522849.html