ASTM D5293-2017 Standard Test Method for Apparent Viscosity of Engine Oils and Base Stocks Between –10 C and –35 C Using Cold-Cranking Simulator《使.pdf
《ASTM D5293-2017 Standard Test Method for Apparent Viscosity of Engine Oils and Base Stocks Between –10 C and –35 C Using Cold-Cranking Simulator《使.pdf》由会员分享,可在线阅读,更多相关《ASTM D5293-2017 Standard Test Method for Apparent Viscosity of Engine Oils and Base Stocks Between –10 C and –35 C Using Cold-Cranking Simulator《使.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5293 17Standard Test Method forApparent Viscosity of Engine Oils and Base StocksBetween 10 C and 35 C Using Cold-Cranking Simulator1This standard is issued under the fixed designation D5293; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the laboratory determination ofapparent viscosity of engine
3、 oils and base stocks by coldcranking simulator (CCS) at temperatures between 10 C and35 C at shear stresses of approximately 50 000 Pa to100 000 Pa and shear rates of approximately 105to 104s1forviscosities of approximately 900 mPas to 25 000 mPas. Therange of an instrument is dependent on the inst
4、rument modeland software version installed. Apparent Cranking Viscosityresults by this method are related to engine-cranking charac-teristics of engine oils.1.2 A special procedure is provided for measurement ofhighly viscoelastic oils in manual instruments. See AppendixX2.1.3 Procedures are provide
5、d for both manual and automateddetermination of the apparent viscosity of engine oils using thecold-cranking simulator.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thes
6、afety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific warningstatements are given in Section 8.1.6 This internationa
7、l standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committe
8、e.2. Referenced Documents2.1 ASTM Standards:2D2162 Practice for Basic Calibration of Master Viscometersand Viscosity Oil StandardsD2602 Test Method for Apparent Viscosity of Engine OilsAt Low Temperature Using the Cold-Cranking Simulator(Withdrawn 1993)3D4057 Practice for Manual Sampling of Petroleu
9、m andPetroleum Products2.2 ISO Standard:ISO 17025 General Requirements for the Competence ofTesting and Calibration Laboratories43. Terminology3.1 Definitions:3.1.1 Newtonian oil or fluid, none that exhibits a constantviscosity at all shear rates.3.1.2 non-Newtonian oil or fluid, none that exhibits
10、aviscosity that varies with changing shear stress or shear rate.3.1.3 viscosity, ,nthe property of a fluid that determinesits internal resistance to flow under stress, expressed by: 5(1)where: = the stress per unit area, and = the rate of shear.3.1.3.1 DiscussionIt is sometimes called the coefficien
11、t ofdynamic viscosity. This coefficient is thus a measure of theresistance to flow of the liquid. In the SI, the unit of viscosityis the pascal-second; for practical use, a submultiple(millipascal-second) is more convenient and is customarilyused. The millipascal second is 1 cP (centipoise).1This te
12、st method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.07 on Flow Properties.Current edition approved July 1, 2017. Published August 2017. Originallyapproved in 1991. Last previous edition appro
13、ved in 2015 as D5293 15. DOI:10.1520/D5293-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last appro
14、ved version of this historical standard is referenced onwww.astm.org.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr
15、Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommen
16、dations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13.2 Definitions of Terms Specific to This Standard:3.2.1 apparent viscosity, nthe viscosity obtained by use ofthis test method.3.2.1.1 DiscussionSince many engine oils are non-Newtonian at low temperature, ap
17、parent viscosity can varywith shear rate.3.2.2 calibration oils, noils with known viscosity andviscosity/temperature functionality that are used to define thecalibration relationship between viscosity and cold-crankingsimulator rotor speed.3.2.3 check oil, na batch of test oil used to monitormeasure
18、ment performance.3.2.4 test oil, nany oil for which the apparent viscosity isto be determined by use of this test method.3.2.5 viscoelastic oil, na non-Newtonian oil or fluid thatclimbs up the rotor shaft during rotation.4. Summary of Test Method4.1 An electric motor drives a rotor that is closely f
19、ittedinside a stator. The space between the rotor and stator is filledwith oil. Test temperature is measured near the stator inner walland maintained by removing heat with a controlled process tomaintain a constant stator temperature during test. The speed ofthe rotor is calibrated as a function of
20、viscosity. Test oilviscosity is determined from this calibration and the measuredrotor speed.5. Significance and Use5.1 The CCS apparent viscosity of automotive engine oilscorrelates with low temperature engine cranking. CCS appar-ent viscosity is not suitable for predicting low temperature flowto t
21、he engine oil pump and oil distribution system. Enginecranking data were measured by the Coordinating ResearchCouncil (CRC) L-495test with reference oils that had viscosi-ties between 600 mPas and 8400 mPas (cP) at 17.8 C andbetween 2000 mPas and 20 000 mPas (cP) at 28.9 C. Thedetailed relationship
22、between this engine cranking data andCCS apparent viscosities is in Appendixes X1 and X2 of the1967 T edition of Test Method D26026and CRC Report 409.5Because the CRC L-49 test is much less precise and standard-ized than the CCS procedures, CCS apparent viscosity need notaccurately predict the engin
23、e cranking behavior of an oil in aspecific engine. However, the correlation of CCS apparentviscosity with average CRC L-49 engine cranking results issatisfactory.5.2 The correlation between CCS and apparent viscosityand engine cranking was confirmed at temperatures between1 C and 40 C by work on 17
24、commercial engine oils (SAEgrades 5W, 10W, 15W, and 20W). Both synthetic and mineraloil based products were evaluated. See ASTM STP 621.75.3 A correlation was established in a low temperatureengine performance study between light duty engine startabil-ity and CCS measured apparent viscosity. This st
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD52932017STANDARDTESTMETHODFORAPPARENTVISCOSITYOFENGINEOILSANDBASESTOCKSBETWEEN 10 CAND 35 CUSINGCOLDCRANKINGSIMULATOR

链接地址:http://www.mydoc123.com/p-522696.html