《ASTM D6449-1999(2008) 837 Standard Test Method for Flow of Fine Aggregate Concrete for Fabric Formed Concrete (Flow Cone Method)《钢筋混凝土所用混合好的混凝土流量标准试验方法(流动锥法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6449-1999(2008) 837 Standard Test Method for Flow of Fine Aggregate Concrete for Fabric Formed Concrete (Flow Cone Method)《钢筋混凝土所用混合好的混凝土流量标准试验方法(流动锥法)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6449 99 (Reapproved 2008)Standard Test Method forFlow of Fine Aggregate Concrete for Fabric FormedConcrete (Flow Cone Method)1This standard is issued under the fixed designation D 6449; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure, used both in thelaboratory and in the field, for d
3、etermining the time of efflux ofa specified volume of the fine aggregate concrete through astandardized flow cone and used for fabric formed concrete(FFC); however, the test method may also be used for otherfluid concrete.1.2 It is for use with fine aggregate concrete containing fineaggregate as def
4、ine in Specification C 33.1.3 This test method is intended for use with fine aggregateconcrete having an efflux time 9 to 15 s.1.4 The values stated in SI units are to be regarded as thestandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use.
5、 It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC 39/C 39M Test Method for Compressi
6、ve Strength of Cy-lindrical Concrete SpecimensC 94/C 94M Specification for Ready-Mixed ConcreteC 109/C 109M Test Method for Compressive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C 1064/C 1064M Test Method for Temperature of FreshlyMixed Hydraulic-Cement Concrete3. Summa
7、ry of Test Method3.1 The time of efflux of a specified volume of fineaggregate concrete from a standardized flow cone is measured.4. Significance and Use4.1 This test method is applicable to the determination ofthe fluidity of various fluid fine aggregate concrete mixtures.5. Interferences5.1 The pr
8、esence of solid particles retained on the 9.53 mm(38 in.) sieve or lumps of unmixed material in the fineaggregate may cause the fine aggregate concrete to flowunevenly through the discharge tube of the flow cone or stopthe flow completely. Uneven flow will result in slower transitof the fine aggrega
9、te concrete, thereby indicating a falseconsistency.6. Apparatus6.1 Flow Cone, the dimensions as shown in Fig. 1. The bodyand discharge tube can be stainless steel, cast aluminum, orother essentially noncorroding metal.6.2 Receiving Container, capacity 2000 mL (2.114 qt),minimum.6.3 Ring Stand or oth
10、er devise, capable of supporting theflow cone in a vertical, steady position over the receivedcontainer.6.4 Level, carpenters or similar.6.5 Stop Watch, least reading of not more than 0.2 s.6.6 Thermometer, having a range from 18 to 49C (0 to120F) and conforming to the requirements for ASTM ther-mom
11、eter No. 36 degrees C. Other thermometers of the requiredaccuracy, including the metal immersion type, are acceptable.7. Test Sample7.1 The fine aggregate concrete test sample shall be inexcess of 1725 mL (1.823 qt) and shall be representative of thefine aggregate concrete in the mixer.7.2 When samp
12、ling and testing is being done for thepurpose of proportioning or comparing mixes or for qualifyingmaterials, the temperature of the fine aggregate concrete shallbe in accordance with Specification C 94, unless otherwisespecified.8. Calibration of Apparatus8.1 Mount the flow cone firmly in such a ma
13、nner that it isfree of vibration. Level the top to assure verticality. Close theoutlet of the discharge tube with a finger or a stopper. Introduce1This test method is under the jurisdiction ofASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.25 on Erosion andSed
14、iment Control Technology.Current edition approved Jan. 1, 2008. Published February 2008. Originallyapproved in 1999. Last previous edition approved in 1999 as D 6449 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annua
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD644919992008837STANDARDTESTMETHODFORFLOWOFFINEAGGREGATECONCRETEFORFABRICFORMEDCONCRETEFLOWCONEMETHOD

链接地址:http://www.mydoc123.com/p-522539.html