《ASTM D6418-2004 Standard Practice for Using the Disposable En Core Sampler for Sampling and Storing Soil for Volatile Organic Analysis《用一次性芯取样器取样和储存土壤分析挥发性有机化合物的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6418-2004 Standard Practice for Using the Disposable En Core Sampler for Sampling and Storing Soil for Volatile Organic Analysis《用一次性芯取样器取样和储存土壤分析挥发性有机化合物的标准实施规程》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6418 04Standard Practice forUsing the Disposable En Core Sampler for Sampling andStoring Soil for Volatile Organic Analysis1This standard is issued under the fixed designation D 6418; the number immediately following the designation indicates the year oforiginal adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is intended for application to soils that maycontain volatile waste constit
3、uents.1.2 This practice provides a procedure for using the dispos-able En Core2sampler to collect and store a soil sample forvolatile organic analysis.1.3 It is recommended that this standard be used in conjunc-tion with Guide D 4547 and Guide D 4687.1.4 This standard does not purport to address all
4、 of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1ASTM takes no position respecting the validity of any pate
5、ntrights asserted in connection with any item mentioned in this standard.Users of this standard are expressly advised that determination of thevalidity of any such patent rights, and the risk of infringement of suchrights, are entirely their own responsibility.2. Referenced Documents2.1 ASTM Standar
6、ds:3D 2777 Practice for Determination of Precision and Bias ofApplicable Methods of Committee D-19 on WaterD 4547 Guide for Sampling Waste and Soils for VolatileOrganicsD 4687 Guide for General Planning of Waste SamplingD 5792 Practice for Generation of Environmental DataRelated to Waste Management
7、Activities: Development ofData Quality Objectives3. Summary of Practice3.1 This practice provides a procedure for using the dispos-able En Core sampler to collect and store a soil sample ofapproximately 5 or 25 g for volatile organic analysis. The EnCore sampler, which consists of a coring body/stor
8、age cham-ber, O-ring sealed plunger, and O-ring sealed cap, is designedto collect and hold a soil sample during shipment to thelaboratory for analysis.3.2 After the sample is collected in the En Core sampler, thecoring body/storage chamber is sealed with a slide-on cap andimmediately becomes a sampl
9、e storage chamber. To minimizeloss of volatile compounds due to volatilization, or biodegra-dation, or both, from the time of collection until analysis orchemical preservation in the laboratory (see Guide D 4547),sample storage options are specified at 4 6 2C for up to 48 h;at 7 to 21C for up to 14
10、days; or at 4 6 2C for up to 48 hfollowed by storage at 7 to 21C for up to five days (seeAppendix X1 and reports referenced in footnotes 4, 5, and 6 forinformation on the performance of the En Core sampler underthese storage conditions).4,5,6Storage of samples in the EnCore sampler at 4 6 2C or 7 to
11、 21C for longer holdingtimes than those listed above is an option, provided it can beshown that the longer storage time used does not influence theconcentrations of the volatile organic compounds (VOCs) ofinterest in the samples, or that the data generated by analysis ofthe samples meet the data qua
12、lity objectives (DQOs) (seePractice D 5792). This practice does not use methanol preser-vation or other chemical preservatives in the field.4. Significance and Use4.1 This practice is for use in collecting and storing 5- or25-g soil samples for volatile organic analysis in a manner thatminimizes los
13、s of contaminants due to volatilization, or bio-degradation, or both. The En Core sampler serves as both thesampling device and sample storage chamber.1This practice is under the jurisdiction of ASTM Committee D34 on WasteManagement and is the direct responsibility of Subcommittee D34.01.03 onSampli
14、ng Equipment.Current edition approved Feb. 1, 2004. Published April 2004. Originallyapproved in 1999 as D 6418 99. Last previous edition approved in 2003 asD 6418 03.2En Core is a registered trademark of En Novative Technologies, Inc., GreenBay, WI. The En Core sampler is covered by a patent. Intere
15、sted parties are invitedto submit information regarding the identification of an alternative(s) to thispatented item to the ASTM Headquarters. Your comments will receive carefulconsideration at a meeting of the responsible technical committee, which you mayattend.3For referenced ASTM standards, visi
16、t the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Hewitt, A. D., Frozen Storage of Soil Samples for Volatile Organic CompoundAnalysis, Environment
17、al Testing and Analysis, Vol 8, No. 5, 1999, pp. 1825.5A copy of the research report describing the study performed to evaluate theprecision of the En Core sampler to store low VOC concentrations is available fromASTM Headquarters. Request RR: D341014.6A copy of the research report describing the st
18、udy performed to evaluate theperformance of the En Core sampler at 7 6 1C and 21 6 2C is available fromASTM Headquarters. Request RR: D34-1015.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2 In performing the practice, the integr
19、ity of the soilsample structure is maintained during sample collection, stor-age, and transfer in the laboratory for analysis or preservation.4.3 During sample collection, storage, and transfer, there isvery limited exposure of the sample to the atmosphere.4.4 Laboratory subsampling is not required
20、when perform-ing this practice. The sample is expelled directly from thecoring body/storage chamber into the appropriate container foranalysis or preservation without disrupting the integrity of thesample. Subsampling from the En Core device should not beperformed to obtain smaller sample sizes for
21、analysis.4.5 This practice specifies sample storage in the En Coresampler at 4 6 2C for up to 48 h; at 7 to 21C for up to 14days; or at 4 6 2C for up to 48 h followed by storage at 7 to21C for up to five days (see Appendix X1 and reportsreferenced in footnotes 4, 5, and 6 for information on theperfo
22、rmance of the En Core sampler under these storageconditions).4,5,6Storage of samples in the En Core sampler at4 6 2C or 7 to 21C for longer holding times than thoselisted above is an option, provided it can be shown that thelonger storage time used does not influence the concentrationsof the VOCs of
23、 interest in the samples, or that the datagenerated by analysis of the samples meet the DQOs (seePractice D 5792).4.6 This practice does not use methanol preservation orother chemical preservatives in the field. As a result, there areno problems associated with flammability hazards, shippingrestrict
24、ions, or dilution of samples containing low volatileconcentrations due to solvents being added to samples in thefield.4.7 The En Core sampler is a single-use device. It shouldnot be cleaned, or reused, or both.4.8 This practice cannot be used for sampling cementedmaterial, consolidated material, or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD64182004STANDARDPRACTICEFORUSINGTHEDISPOSABLEENCORESAMPLERFORSAMPLINGANDSTORINGSOILFORVOLATILEORGANICANALYSIS

链接地址:http://www.mydoc123.com/p-522464.html