《ASTM D6417-2009 923 Standard Test Method for Estimation of Engine Oil Volatility by Capillary Gas Chromatography《用毛细管气相色谱法评定发动机油挥发性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6417-2009 923 Standard Test Method for Estimation of Engine Oil Volatility by Capillary Gas Chromatography《用毛细管气相色谱法评定发动机油挥发性的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6417 09An American National StandardStandard Test Method forEstimation of Engine Oil Volatility by Capillary GasChromatography1This standard is issued under the fixed designation D 6417; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers an estimation of the amount ofengine oil volatilized at 371C (
3、700F).1.1.1 This test method can also be used to estimate theamount of oil volatilized at any temperature between 126 and371C, if so desired.1.2 This test method is limited to samples having an initialboiling point (IBP) greater than 126C (259F) or the firstcalibration point and to samples containin
4、g lubricant base oilswith end points less than 615C (1139F) or the last n-paraffinsin the calibration mixture. By using some instruments andcolumns, it is possible to extend the useful range of the testmethod.1.3 This test method uses the principles of simulated distil-lation methodology.1.4 This te
5、st method may be applied to both lubricant oilbase stocks and finished lubricants containing additive pack-ages. These additive packages generally contain high molecu-lar weight, nonvolatile components that do not elute from thechromatographic column under the test conditions. The calcu-lation proce
6、dure used in this test method assumes that all of thesample elutes from the column and is detected with uniformresponse. This assumption is not true for samples with non-volatile additives, and application of this test method undersuch conditions will yield results higher than expected. For thisreas
7、on, results by this test method are reported as area percentof oil.1.5 The values stated in SI units are to be regarded asstandard. The values stated in inch-pound units are providedfor information only.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with
8、its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 2887 Test Method for Boiling Range Distribution ofPetroleum Fractio
9、ns by Gas ChromatographyD 4626 Practice for Calculation of Gas ChromatographicResponse FactorsD 5800 Test Method for Evaporation Loss of LubricatingOils by the Noack MethodE 355 Practice for Gas Chromatography Terms and Rela-tionshipsE 594 Practice for Testing Flame Ionization Detectors Usedin Gas o
10、r Supercritical Fluid ChromatographyE 1510 Practice for Installing Fused Silica Open TubularCapillary Columns in Gas Chromatographs2.2 Coordinating European Council Standard:CEC L-4093 Evaporation Loss of Lubricating Oils(NOACK Evaporative Tester)33. Terminology3.1 DefinitionsThis test method makes
11、reference to manycommon gas chromatographic procedures, terms, and relation-ships. Detailed definitions of these can be found in PracticesE 355, E 594, and E 1510.3.2 Definitions of Terms Specific to This Standard:3.2.1 area slicethe area resulting from the integration ofthe chromatographic detector
12、 signal within a specified reten-tion time interval. In area slice mode (see 6.5.2), peak detectionparameters are bypassed and the detector signal integral isrecorded as area slices of consecutive, fixed duration timeintervals.3.2.2 corrected area slicean area slice corrected for base-line offset by
13、 subtraction of the exactly corresponding areaslice in a previously recorded blank (nonsample) analysis.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.04.0H on Chromatographic Distribution Meth
14、ods.Current edition approved June 1, 2009. Published June 2009. Originallyapproved in 1999. Last previous edition approved in 2003 as D 641703.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards vo
15、lume information, refer to the standards Document Summary page onthe ASTM website.3Available from Coordinating European Council (CEC), C/o Interlynk Admin-istrative Services, Ltd., P.O. Box 6475, Earl Shilton, Leicester, LE9 9ZB, U.K.,http:/www.cectests.org.1*A Summary of Changes section appears at
16、the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.3 cumulative corrected areathe accumulated sum ofcorrected area slices from the beginning of the analysis througha given retention time (RT), ignoring any no
17、nsample area (forexample, solvent).3.2.4 slice ratethe time interval used to integrate thecontinuous (analog) chromatographic detector response duringan analysis. The slice rate is expressed in hertz (for example,integrations or slices per second).3.2.5 slice timethe cumulative slice rate (analysis
18、time)associated with each area slice throughout the chromatographicanalysis. The slice time is the time at the end of eachcontiguous area slice.3.2.6 total sample areathe cumulative corrected areafrom the initial point to the final area point.3.3 AbbreviationsAcommon way to abbreviate hydrocar-bon c
19、ompounds is to designate the number of carbon atoms inthe compound. A prefix is used to indicate the carbon chainform while a subscript suffix denotes the number of carbonatoms (for example, normal decane n-C10; iso-tetradecane =i-C14).4. Summary of Test Method4.1 A nonpolar open tubular (capillary)
20、 gas chromato-graphic column is used to elute the hydrocarbon components ofthe sample in order of increasing boiling point.4.2 A sample aliquot is diluted with a viscosity reducingsolvent and introduced into the chromatographic system. Atleast one laboratory analyzed samples using neat injectionwith
21、out solvent dilution. The precision of the method wascalculated on diluted samples. If a laboratory chooses to useneat injection, it should first confirm that it is obtaining similarresults. Sample vaporization is provided by separate heating ofthe point of injection or in conjunction with column ov
22、enheating.4.3 The column oven temperature is raised at a reproduciblelinear rate to effect separation of the hydrocarbon componentsin order of increasing boiling point. The elution of samplecomponents is quantitatively determined by a flame ionizationdetector (FID). The detector signal integral is r
23、ecorded as areaslices for consecutive RT intervals during the analysis.4.4 RTs of known hydrocarbons spanning the scope of thetest method (C8-C60) are determined and correlated to theirboiling point temperatures. The RT at 371C (700F) iscalculated using linear regression, utilizing the calibrationde
24、veloped from the n-paraffins. The cumulative corrected areaof the sample determined to the 371C RT is used to calculatethe percentage of oil volatilized at 371C.5. Significance and Use5.1 The determination of engine oil volatility at 371C(700F) is a requirement in some lubricant specifications.5.2 T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD64172009923STANDARDTESTMETHODFORESTIMATIONOFENGINEOILVOLATILITYBYCAPILLARYGASCHROMATOGRAPHY 毛细管

链接地址:http://www.mydoc123.com/p-522462.html