ASTM D6319-2000a(2005)e1 488 Standard Specification for Nitrile Examination Gloves for Medical Application.pdf
《ASTM D6319-2000a(2005)e1 488 Standard Specification for Nitrile Examination Gloves for Medical Application.pdf》由会员分享,可在线阅读,更多相关《ASTM D6319-2000a(2005)e1 488 Standard Specification for Nitrile Examination Gloves for Medical Application.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6319 00a (Reapproved 2005)1Standard Specification forNitrile Examination Gloves for Medical Application1This standard is issued under the fixed designation D 6319; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorially corrected 7.5.1 in December 2008.1. Scope1.1 This specification covers certain requirements for nitrileru
3、bber gloves used in conducting medical examinations anddiagnostic and therapeutic procedures.1.2 This specification covers nitrile rubber examinationgloves that fit either hand, paired gloves, and gloves by size. Italso provides for packaged sterile or nonsterile or bulk non-sterile nitrile rubber e
4、xamination gloves.1.3 This specification is similar to that of SpecificationD 3578 for rubber examination gloves.2. Referenced Documents2.1 ASTM Standards:2D 412 Test Methods for Vulcanized Rubber and Thermo-plastic ElastomersTensionD 573 Test Method for RubberDeterioration in an AirOvenD 3578 Speci
5、fication for Rubber Examination GlovesD 3767 Practice for RubberMeasurement of DimensionsD 5151 Test Method for Detection of Holes in MedicalGlovesD 6124 Test Method for Residual Powder on MedicalGloves2.2 ISO Standard:ISO 2859 Sampling Procedures and Tables for Inspectionby Attributes32.3 Other Doc
6、uments:U.S. Pharmacopeia43. Significance and Use3.1 The specification is intended as a referee procedure forevaluating the performance and safety of nitrile rubber exami-nation gloves. It is not intended for testing prior to routine lotrelease. The safe and proper use of nitrile rubber examinationgl
7、oves is beyond the scope of this specification.4. Material4.1 Any nitrile rubber polymer compound may be used thatpermits the glove to meet the requirements of this specification.4.2 A lubricant that meets the current requirements of theU.S. Pharmacopeia for absorbable dusting powder may beapplied t
8、o the glove. Other lubricants may be used if theirsafety and efficacy have been previously established.4.3 The inside and outside surface of the nitrile rubberexamination gloves shall be free of talc.5. Sampling5.1 For referee purposes, gloves shall be sampled fromfinished product, after sterilizati
9、on when labeled sterile, andinspected in accordance with ISO 2859. The inspection levelsand acceptable quality levels (AQL) shall conform to thosespecified in Table 1, or as agreed upon between the purchaserand the seller, if the latter is more comprehensive.6. Performance Requirements6.1 Gloves, sa
10、mpled in accordance with Section 5, shallmeet the following referee performance requirements:6.1.1 Product comply with requirements for sterility whentested in accordance with 7.2 when labeled sterile.6.1.2 Shall comply with freedom from holes when tested inaccordance with 7.3.6.1.3 Have consistent
11、physical dimensions in accordancewith 7.4.6.1.4 Have acceptable physical property characteristics inaccordance with 7.5.6.1.5 Have a powder residue limit of 2.0 mg in accordancewith 7.66.1.6 Have a recommended maximum powder limit of 10mg/dm2in accordance with 7.7.1This specification is under the ju
12、risdiction ofASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.40 on Consumer RubberProducts.Current edition approved Dec. 1, 2005. Published December 2005. Originallyapproved in 1999. Last previous edition approved in 2000 as D 6319 00a3.2For referenced ASTM standards
13、, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute, 25 W. 43rd St., 4thFloor, New York,
14、NY 10036.4U. S. Pharmacopeia, latest edition, Mack Publishing Co., Easton, PA 19175.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Referee Test Methods7.1 The following tests shall be conducted to ensure therequirements of Sectio
15、n 6, as prescribed in Table 1:7.2 Sterility TestTesting for sterility shall be conducted inaccordance with the latest edition of the U.S. Pharmacopeia.7.3 Freedom from HolesTesting for freedom from holesshall be conducted in accordance with Test Method D 5151.7.4 Physical Dimensions Test:7.4.1 The g
16、loves shall comply with the dimension require-ments prescribed in Table 2.7.4.2 The length shall be expressed in millimetres as mea-sured from the tip of the middle finger to the outside edge ofthe cuff.7.4.3 The width of the palm shall be expressed in millime-tres as measured at a level between the
17、 base of the index fingerand the base of the thumb. Values of width per size other thanlisted shall meet the stated tolerance specified in Table 2.7.4.4 The minimum thickness shall be expressed in milli-metres as specified in Table 2 when using a dial or digitalmicrometer that meets requirements des
18、cribed in Test MethodsD 412 and Practice D 3767, and in the locations indicated inFig. 1. For referee tests, cutting the glove is necessary to obtainsingle-thickness measurements. (See Practice D 3767 for moreinformation.)7.5 Physical Requirements Test:7.5.1 Before and after accelerated aging, the g
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD63192000A2005E1488STANDARDSPECIFICATIONFORNITRILEEXAMINATIONGLOVESFORMEDICALAPPLICATIONPDF

链接地址:http://www.mydoc123.com/p-522157.html