ASTM D6312-1998(2005) Standard Guide for Developing Appropriate Statistical Approaches for Groundwater Detection Monitoring Programs《地下水探测监测程序用开发适当的统计近似值的标准指南》.pdf
《ASTM D6312-1998(2005) Standard Guide for Developing Appropriate Statistical Approaches for Groundwater Detection Monitoring Programs《地下水探测监测程序用开发适当的统计近似值的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6312-1998(2005) Standard Guide for Developing Appropriate Statistical Approaches for Groundwater Detection Monitoring Programs《地下水探测监测程序用开发适当的统计近似值的标准指南》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6312 98 (Reapproved 2005)Standard Guide forDeveloping Appropriate Statistical Approaches for Ground-Water Detection Monitoring Programs1This standard is issued under the fixed designation D 6312; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the context of ground-water monitor-ing at waste disposal f
3、acilities. Regulations have requiredstatistical methods as the basis for investigating potentialenvironmental impact due to waste disposal facility operation.Owner/operators must perform a statistical analysis on aquarterly or semiannual basis.Astatistical test is performed oneach of many constituen
4、ts (for example, 10 to 50 or more) foreach of many wells (5 to 100 or more). The result is potentiallyhundreds, and in some cases, a thousand or more statisticalcomparisons performed on each monitoring event. Even if thefalse positive rate for a single test is small (for example, 1 %),the possibilit
5、y of failing at least one test on any monitoringevent is virtually guaranteed. This assumes you have done thecorrect statistic in the first place.1.2 This guide is intended to assist regulators and industryin developing statistically powerful ground-water monitoringprograms for waste disposal facili
6、ties. The purpose of thisguide is to detect a potential ground-water impact from thefacility at the earliest possible time while simultaneouslyminimizing the probability of falsely concluding that thefacility has impacted ground water when it has not.1.3 When applied inappropriately, existing regula
7、tion andguidance on statistical approaches to ground-water monitoringoften suffer from a lack of statistical clarity and often imple-ment methods that will either fail to detect contamination whenit is present (a false negative result) or conclude that the facilityhas impacted ground water when it h
8、as not (a false positive).Historical approaches to this problem have often sacrificed onetype of error to maintain control over the other. For example,some regulatory approaches err on the side of conservatism,keeping false negative rates near zero while false positive ratesapproach 100 %.1.4 The pu
9、rpose of this guide is to illustrate a statisticalground-water monitoring strategy that minimizes both falsenegative and false positive rates without sacrificing one for theother.1.5 This guide is applicable to statistical aspects of ground-water detection monitoring for hazardous and municipal soli
10、dwaste disposal facilities.1.6 It is of critical importance to realize that on the basis ofa statistical analysis alone, it can never be concluded that awaste disposal facility has impacted ground water. A statisti-cally significant exceedance over background levels indicatesthat the new measurement
11、 in a particular monitoring well for aparticular constituent is inconsistent with chance expectationsbased on the available sample of background measurements.1.7 Similarly, statistical methods can never overcome limi-tations of a groundwater monitoring network that might arisedue to poor site charac
12、terization, well installation and location,sampling, or analysis.1.8 It is noted that when justified, intra-well comparisonsare generally preferable to their inter-well counterparts becausethey completely eliminate the spatial component of variability.Due to the absence of spatial variability, the u
13、ncertainty inmeasured concentrations is decreased, making intra-well com-parisons more sensitive to real releases (that is, false negatives)and false positive results due to spatial variability are com-pletely eliminated.1.9 Finally, it should be noted that the statistical methodsdescribed here are
14、not the only valid methods for analysis ofground-water monitoring data. They are, however, currentlythe most useful from the perspective of balancing site-widefalse positive and false negative rates at nominal levels.Amorecomplete review of this topic and the associated literature ispresented by Gib
15、bons (1).21.10 The values stated in both inch-pound and SI units areto be regarded as the standard. The values given in parenthesesare for information only.1.11 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user o
16、f this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.12 This guide offers an organized collection of informa-tion or a series of options and does not recommend a specificcourse of action. This document cannot
17、replace education or1This guide is under the jurisdiction ofASTM Committee D18 on Soil and Rockand is the direct responsibility of Subcommittee D18.21 on Ground Water andVadose Zone Investigations.Current edition approved Jan. 1, 2005. Published February 2005. Originallyapproved in 1998. Last previo
18、us edition approved in 1998 as D 631298.2The boldface numbers given in parentheses refer to a list of references at theend of the text.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.experience and should be used in conjunction with
19、professionaljudgment. Not all aspects of this guide may be applicable in allcircumstances. This ASTM standard is not intended to repre-sent or replace the standard of care by which the adequacy ofa given professional service must be judged, nor should thisdocument be applied without consideration of
20、 a projects manyunique aspects. The word “Standard” in the title of thisdocument means only that the document has been approvedthrough the ASTM consensus process.2. Terminology2.1 Definitions:2.1.1 assessment monitoring program, nground-watermonitoring that is intended to determine the nature and ex
21、tentof a potential site impact following a verified statisticallysignificant exceedance of the detection monitoring program.2.1.2 combined Shewhart (CUSUM) control chart, nastatistical method for intra-well comparisons that is sensitive toboth immediate and gradual releases.2.1.3 detection limit (DL
22、), nthe true concentration atwhich there is a specified level of confidence (for example,99 % confidence) that the analyte is present in the sample (2).2.1.4 detection monitoring program, nground-watermonitoring that is intended to detect a potential impact from afacility by testing for statisticall
23、y significant changes ingeochemistry in a downgradient monitoring well relative tobackground levels.2.1.5 intra-well comparisons, na comparison of one ormore new monitoring measurements to statistics computedfrom a sample of historical measurements from that same well.2.1.6 inter-well comparisons, n
24、a comparison of a newmonitoring measurement to statistics computed from a sampleof background measurements (for example, upgradient versusdowngradient comparisons).2.1.7 prediction interval or limit, na statistical estimate ofthe minimum or maximum concentration, or both, that willcontain the next s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD631219982005STANDARDGUIDEFORDEVELOPINGAPPROPRIATESTATISTICALAPPROACHESFORGROUNDWATERDETECTIONMONITORINGPROGRAMS

链接地址:http://www.mydoc123.com/p-522141.html