《ASTM D6306-2010 0000 Standard Guide for Placement and Use of Diffusion Controlled Passive Monitors for Gaseous Pollutants in Indoor Air《室内空气中的气态污染物用扩散控制无源监测仪的放置和使用的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6306-2010 0000 Standard Guide for Placement and Use of Diffusion Controlled Passive Monitors for Gaseous Pollutants in Indoor Air《室内空气中的气态污染物用扩散控制无源监测仪的放置和使用的标准指南》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6306 10Standard Guide forPlacement and Use of Diffusion Controlled Passive Monitorsfor Gaseous Pollutants in Indoor Air1This standard is issued under the fixed designation D6306; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the placement and use of diffusioncontrolled monitors in the indoor atmosphere
3、.1.2 Diffusion controlled passive monitors within this guideinclude both area and personal monitors for use in residences,public buildings, offices, and other non-industrial workplacesand dwelling environments. A passive monitor is any airmonitor that does not utilize electrical or mechanical power
4、inorder to supply air to the sorbent media or chemical reactantwithin the monitor and sample according to Ficks first law ofdiffusion.1.3 The purpose of this guide is to ensure uniformity ofsampling within a variety of indoor environments and tofacilitate comparison of results.1.4 The values stated
5、in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and he
6、alth practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD1357 Practice for Planning the Sampling of the AmbientAtmosphereD4597 Practice for Sampling Workplace At
7、mospheres toCollect Gases or Vapors with Solid Sorbent DiffusiveSamplersD3614 Guide for Laboratories Engaged in Sampling andAnalysis of Atmospheres and Emissions3. Terminology3.1 DefinitionsFor definitions of terms used in this guiderefer to Terminology D1356.3.2 Definitions of Terms Specific to Thi
8、s Standard:3.2.1 passive monitora diffusion controlled air monitorthat does not utilize electrical or mechanical power in order tosupply air to the sorbent media or chemical reactant within themonitor. These monitors may be worn by an individual(personal passive monitor) or used as sampling devices
9、withinspecific locations (area passive monitor).4. Summary of Guide4.1 Contaminants in air are sampled by collection with asorbent or chemically reactive medium in order to undergosubsequent analysis for determination of concentration. Con-taminants in air are transported to the sorption medium orre
10、acting chemical through vapor or gas diffusion. During thesampling process, the compounds, in a molecular state, diffusefrom the environment adjacent to the sampler through a firstregion of defined geometric structure and into a secondadsorbing region containing the sorbent.4.2 Guidance is provided
11、for the placement, handling, anduse of passive air monitors within an indoor environment.5. Significance and Use5.1 The objective of this guide is to provide guidance for theplacement and use of passive monitors that when uniformlyapplied enables the user to eliminate many interferences in thesampli
12、ng of indoor air. Since the analysis of the indoorenvironment by passive air monitors is influenced by manyfactors other than the method of sampling, efforts are made tominimize interfering factors and maintain the air at conditionstypical of the measurement location within the vicinity of thepassiv
13、e air monitor. However, when performing diagnostic orspecial measurements, non-typical indoor air environment1This method is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved April 1, 2010. Publis
14、hed April 2010. Originallyapproved in 1998. Last previous edition approved in 2003 as D6306 - 98(2003).DOI: 10.1520/D6306-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information,
15、refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.conditions may be desirable or required. Thus, the objectives ofa sampling study may determine the conditions needed fors
16、ampling.5.2 Passive sampling provides for time integrated measure-ments. Passive monitors are usually placed in an indoorenvironment over a time period to obtain a cumulative sample;hence, interfering factors should be anticipated and eliminatedwhere possible. Passive monitors often lack the sensiti
17、vity tomeasure short-term peak concentrations.5.3 With suitable instruction regarding placement of passivemonitors, placement and retrieval of the monitors can beperformed by unskilled personnel (for example, occupants).6. General Principles6.1 The choice of a passive monitor, characteristics of the
18、sampling site, number of sampling points, number of monitors,and number of sampling periods depends on the objectives ofthe monitoring program.6.2 Passive monitors rely on air currents within an indoorenvironment for circulation of a representative sample atmo-sphere to the vicinity of the monitor.
19、Therefore, it is essentialthat air circulation in the vicinity of the sampler be sufficient tokeep the boundary layer thin enough so that the analyte candiffuse across it, preventing a localized concentration depletionby the monitor. The adequacy of the sampling is directlyinfluenced by the location
20、 and subsequent exposure of themonitor to a representative indoor atmosphere.6.3 The objective of the study may affect the type ofmonitor selected and the location of placement. In generalterms, Practice D1357 will acquaint the user with establishedoverall study considerations.7. Sampling with Passi
21、ve Monitors7.1 Inspect the monitor and package carefully. The monitoror its protective packaging may have been damaged duringshipment. The user should not directly contact the monitor withbare skin and, in no case, permit anything to contact thesampling face.7.2 Calibration of the Passive MonitorInf
22、ormation relat-ing to calibration may be found in Practice D4597. Thesedocuments also provide information relating to the determina-tion of the required minimum sampling time.7.3 The sampling period begins when lid, cover, or protec-tive container of the monitor is removed to permit sampling bythe m
23、onitor. The starting time of the sampling period should betranscribed to a logbook or appropriate form and on themonitor label. The writing instrument, for example, markers,should not provide the potential of contamination to themonitor. A means of resealing or replacing the monitor lid orcover shou
24、ld be ensured.7.4 The monitor should have a permanently attached iden-tification code or serial number that should be transcribed to alogbook or an appropriate form. The logbook should includeinformation describing the location of the monitor and perti-nent information regarding the building and dep
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD630620100000STANDARDGUIDEFORPLACEMENTANDUSEOFDIFFUSIONCONTROLLEDPASSIVEMONITORSFORGASEOUSPOLLUTANTSININDOORAIR

链接地址:http://www.mydoc123.com/p-522132.html