《ASTM D6166-1997(2003) Standard Test Method for Color of Naval Stores and Related Products (Instrumental Determination of Gardner Color)《松脂制品和相关产品颜色的标准试验方法(加德纳仪器测定颜色)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6166-1997(2003) Standard Test Method for Color of Naval Stores and Related Products (Instrumental Determination of Gardner Color)《松脂制品和相关产品颜色的标准试验方法(加德纳仪器测定颜色)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6166 97 (Reapproved 2003)Standard Test Method forColor of Naval Stores and Related Products (InstrumentalDetermination of Gardner Color)1This standard is issued under the fixed designation D 6166; the number immediately following the designation indicates the year oforiginal adoption
2、or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the quantitative determinationof the color of clear,
3、 yellow/brown, liquid materials using colormeasuring instruments. The results may be invalid if othermaterials are used. The test uses the Gardner color scaledescribed in Test Method D 1544. This test method applies tonaval stores products including tall oil, tall oil fatty acids,rosin, and related
4、products.1.2 This standard does not purport to address all of thesafety concerns, if any, problems associated with its use. It isthe responsibility of the user of this standard to establishappropriate safety and health practices and determine theapplicability of regulatory limitations prior to use.2
5、. Referenced Documents2.1 ASTM Standards:D 1544 Test Method for Color of Transparent Liquids(Gardner Color Scale)2E 177 Practice for the Use of the Terms Precision and Biasin ASTM Test Methods3E 308 Practice for Computing the Colors of Objects byUsing the CIE System3E 691 Practice for Conducting an
6、Interlaboratory Study toDetermine the Precision of a Test Method33. Summary of Test Method3.1 The color of a liquid sample is measured using aninstrument capable of measuring transmitted color and report-ing in Gardner colors or in a color system that can be convertedto Gardner colors.4. Significanc
7、e and Use4.1 This test method provides a more precise way ofmeasuring Gardner color than described in Test MethodD 1544. It is applicable to naval stores products having colorsfrom Gardner 1 to Gardner 18. The Gardner scale is notapplicable to materials with colors lighter than 1 or darker than18.5.
8、 Apparatus5.1 An instrument capable of measuring transmitted colorand reporting the results in the Gardner color scale described inTest Method D 1544. If such an instrument is not available, onemay be used which is capable of measuring transmitted colorand reporting in tristimulus values or chromati
9、city coordinatesusing standard illuminant C and the 2 observer, described inPractice E 308.5.2 Glass Cuvets, 10mm path length, unless a differentpath length is specified by the manufacturer, or5.3 Glass Tubes, clear. Standard Gardner tubes, as describedin Test Method D 1544, or other glass tubes des
10、igned for aspecific instrument may be used. Gardner tubes may provideless accuracy than glass cuvets and should be used only whena decrease in accuracy is acceptable. Glass cuvets should beused for referee situations.6. Calibration and Standardization6.1 Calibrate the instrument following the manufa
11、cturersrecommendations.7. Procedure7.1 Taking care not to touch the measurement area of thesample cell, fill a clean Gardner tube or cuvet with the materialto be tested. If the material is cloudy, first filter it.7.2 Insert the glass tube or cuvet in the instrument andmeasure the color, following th
12、e manufacturers recommendedprocedure.8. Report8.1 Report the color in Gardner color units to a tenth of aGardner unit as given by the instrument or as calculated by themethod in the appendix. Note if the material was filtered.1This test method is under the jurisdiction of Committee D01 on Paint andR
13、elated Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.34 on Naval Stores.Current edition approved July 10, 2003. Published July 2003. Originallyapproved in 1997. Last previous edition approved in 1997 as D 6166 - 97.2Annual Book of ASTM Standards, Vol 06.01
14、.3Annual Book of ASTM Standards, Vol 14.02.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.9. Precision and Bias9.1 Interlaboratory Test ProgramAn interlaboratorystudy of the color of three materials was run in 1996. Each of13 labora
15、tories tested each of the three materials. The design ofthe experiment, similar to that of Practice E 691 and awithin-between analysis of the data are given in ASTMResearch Report.49.2 Test ResultThe precision information given below forGardner color is for the comparison of three test results, each
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD616619972003STANDARDTESTMETHODFORCOLOROFNAVALSTORESANDRELATEDPRODUCTSINSTRUMENTALDETERMINATIONOFGARDNERCOLOR

链接地址:http://www.mydoc123.com/p-521752.html