ASTM D6067-2010 9375 Standard Practice for Using the Electronic Piezocone Penetrometer Tests for Environmental Site Characterization《环境厂址表征用电子锥形透度计的标准使用指南》.pdf
《ASTM D6067-2010 9375 Standard Practice for Using the Electronic Piezocone Penetrometer Tests for Environmental Site Characterization《环境厂址表征用电子锥形透度计的标准使用指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6067-2010 9375 Standard Practice for Using the Electronic Piezocone Penetrometer Tests for Environmental Site Characterization《环境厂址表征用电子锥形透度计的标准使用指南》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6067 10Standard Practice forUsing the Electronic Piezocone Penetrometer Tests forEnvironmental Site Characterization1This standard is issued under the fixed designation D6067; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 The electronic cone penetrometer test often is used todetermine subsurface stratigraphy for geotec
3、hnical and envi-ronmental site characterization purposes (1).2The geotechnicalapplication of the electronic cone penetrometer test is dis-cussed in detail in Test Method D5778, however, the use of theelectronic cone penetrometer test in environmental site char-acterization applications involves furt
4、her considerations thatare not discussed. For environmental site characterization, it ishighly recommended to use the Piezocone (PCPT or CPTu)option in Test Method D5778 so information on hydraulicconductivity and aquifer hydrostatic pressures can be evalu-ated.1.2 The purpose of this practice is to
5、 discuss aspects of theelectronic cone penetrometer test that need to be consideredwhen performing tests for environmental site characterizationpurposes.1.3 The electronic cone penetrometer test for environmentalsite characterization projects often requires steam cleaning thepush rods and grouting t
6、he hole. There are numerous ways ofcleaning and grouting depending on the scope of the project,local regulations, and corporate preferences. It is beyond thescope of this practice to discuss all of these methods in detail.A detailed explanation of grouting procedures is discussed inGuide D6001.1.4 T
7、he electronic cone penetrometer may be be combinedwith other direct push sampling and testing methods. Estimatedsoil types can be confirmed by soil sampling (Guide D6282).Cone penetrometer tests are often used to locate aquifers forinstallation of wells (Practice D5092, Guide D6274). Conepenetromete
8、rs can be equipped with additional sensors forground water quality evaluations (Practice D6187). Location ofother sensors must conform to requirements of Test MethodD5778.1.5 This practice is applicable only at sites where chemical(organic and inorganic) wastes are a concern and is notintended for u
9、se at radioactive or mixed (chemical and radio-active) waste sites.1.6 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
10、is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.8 Standard PracticeThis practice offers a set of instruc-tions for performing one or more specific operations. Thisdocumen
11、t cannot replace education or experience and shouldbe used in conjunction with professional judgment. Not allaspects of this practice may be applicable in all circumstances.This ASTM standard is not intended to represent or replace thestandard of care by which the adequacy of a given professionalser
12、vice must be judged, nor should this document be appliedwithout consideration of a projects many unique aspects. Theword 9Standard9 in the title means only that the document hasbeen approved through the ASTM consensus process.2. Referenced Documents2.1 ASTM Standards:3C150 Specification for Portland
13、 CementD653 Terminology Relating to Soil, Rock, and ContainedFluidsD3740 Practice for Minimum Requirements for AgenciesEngaged in Testing and/or Inspection of Soil and Rock asUsed in Engineering Design and ConstructionD5088 Practice for Decontamination of Field EquipmentUsed at Waste SitesD5092 Prac
14、tice for Design and Installation of Ground WaterMonitoring WellsD5778 Test Method for Electronic Friction Cone and Piezo-cone Penetration Testing of Soils1This practice is under the jurisdiction of ASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.21 on Ground W
15、ater andVadose Zone Investigations.Current edition approved May 1, 2010. Published June 2010. Originallyapproved in 1996. Last previous edition approved in 2003 as D606796(2003) DOI:10.1520/D6067-10.2The boldface numbers in parentheses refer to the list of references at the end ofthis guide.3For ref
16、erenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Co
17、pyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.D6001 Guide for Direct-Push Ground Water Sampling forEnvironmental Site CharacterizationD6187 Practice for Cone Penetrometer Technology Charac-terization of Petroleum Contaminated Sites wi
18、th NitrogenLaser-Induced FluorescenceD6274 Guide for Conducting Borehole Geophysical Log-ging - GammaD6282 Guide for Direct Push Soil Sampling for Environ-mental Site Characterizations3. Terminology3.1 Definitions:3.1.1 For definitions of terms related to this standard, referto Terminology D653.3.1.
19、2 hydraulic conductivity (in field aquifer tests), nthevolume of water at the existing kinematic viscosity that willmove in a unit time under a hydraulic gradient through a unitarea measured at right angles to the direction of flow.3.2 Definitions of Terms Specific to This Standard:3.2.1 baseline, n
20、a set of zero load readings, expressed interms of apparent resistance, that are used as reference valuesduring performance of testing and calibration.3.2.2 bentonite, nthe common name for drilling fluidadditives and well construction products consisting mostly ofnaturally occurring sodium montmorill
21、onite. Some bentoniteproducts have chemical additives that may affect water qualityanalyses.3.2.3 cone, nthe conical point of a cone penetrometer onwhich the end bearing component of penetration resistance isdeveloped.3.2.4 cone resistance, qc, n the end bearing component ofpenetration resistance.3.
22、2.5 cone sounding, na series of penetration readingsperformed at one location over the entire depth when using acone penetrometer.3.2.6 dissipation test, ntest where the dissipation of ex-cess pore water pressure generated during push is monitored toevaluate depth specific hydraulic conductivity and
23、 final pres-sure head of the soil when penetration is stopped.3.2.6.1 DiscussionEither complete or 50 % dissipation ismonitored. Complete dissipation can be used to determineequilibrium pore water pressure and thus hydrostatic head at apoint in the aquifer. The time required for dissipation dependso
24、n the soil type.3.2.7 electronic cone penetrometer, na friction cone pen-etrometer that uses force transducers, such as strain gage loadcells, built into a nontelescoping penetrometer tip for measur-ing within the penetrometer tip, the components of penetrationresistance.3.2.8 electronic piezocone p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD606720109375STANDARDPRACTICEFORUSINGTHEELECTRONICPIEZOCONEPENETROMETERTESTSFORENVIRONMENTALSITECHARACTERIZATION

链接地址:http://www.mydoc123.com/p-521438.html