ASTM D6057-1996(2011) 5000 Standard Test Method for Determining Concentration of Airborne Single-Crystal Ceramic Whiskers in the Workplace Environment by Phase Contrast Microscopy《.pdf
《ASTM D6057-1996(2011) 5000 Standard Test Method for Determining Concentration of Airborne Single-Crystal Ceramic Whiskers in the Workplace Environment by Phase Contrast Microscopy《.pdf》由会员分享,可在线阅读,更多相关《ASTM D6057-1996(2011) 5000 Standard Test Method for Determining Concentration of Airborne Single-Crystal Ceramic Whiskers in the Workplace Environment by Phase Contrast Microscopy《.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6057 96 (Reapproved 2011)Standard Test Method forDetermining Concentration of Airborne Single-CrystalCeramic Whiskers in the Workplace Environment by PhaseContrast Microscopy1This standard is issued under the fixed designation D6057; the number immediately following the designation ind
2、icates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the sampling meth
3、ods andanalysis techniques used to assess the airborne concentration ofsingle-crystal ceramic whiskers (SCCW), such as silicon car-bide and silicon nitride, which may occur in and around theworkplace where these materials are manufactured, processed,transported, or used. This test method is based on
4、 the collectionof fibers by filtration of a known quantity of air through a filter.The filter is subsequently evaluated with a phase contrastmicroscope (PCM) for the number of fibers meeting appropri-ately selected counting criteria. This test method cannotdistinguish among different types of fibers
5、. This test methodmay be appropriate for other man-made mineral fibers(MMMF).1.2 This test method is applicable to the quantitation offibers on a collection filter that are greater than 5 m in length,less than 3 m in width, and have an aspect ratio equal to orgreater than 5:1. The data are directly
6、convertible to astatement of concentration per unit volume of air sampled.Thistest method is limited by the diameter of the fibers visible byPCM (typically greater than 0.25 m in width) and the amountand type of coincident interference particles.1.3 A more definitive analysis may be necessary to con
7、firmthe identity and dimensions of the fibers located with the PCM,especially where other fiber types may be present. Suchtechniques may include scanning electron microscopy (SEM)or transmission electron microscopy (TEM). The use of thesetest methods for the identification and size determination ofS
8、CCW is described in Practice D6058 and Test MethodsD6059 and D6056.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
9、 is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1356 Terminology Relating to Sampling and
10、Analysis ofAtmospheresD4532 Test Method for Respirable Dust in WorkplaceAtmospheres Using Cyclone SamplersD6056 Test Method for Determining Concentration of Air-borne Single-Crystal Ceramic Whiskers in the WorkplaceEnvironment by Transmission Electron MicroscopyD6058 Practice for Determining Concent
11、ration of AirborneSingle-Crystal Ceramic Whiskers in the Workplace Envi-ronmentD6059 Test Method for Determining Concentration of Air-borne Single-Crystal Ceramic Whiskers in the WorkplaceEnvironment by Scanning Electron MicroscopyE691 Practice for Conducting an Interlaboratory Study toDetermine the
12、 Precision of a Test Method3. Terminology3.1 Definitions:3.1.1 analytical sensitivity, nairborne fiber concentrationrepresented by a single fiber counted in the PCM.3.1.1.1 DiscussionAlthough the terms fiber and whiskerare, for convenience, used interchangeably in this test method,whisker is correct
13、ly applied only to single-crystal fiberswhereas a fiber may be single- or poly-crystalline or may benoncrystalline.3.1.2 aspect ratio, nthe ratio of the length of a fiber to itswidth.3.1.3 fiber, nfor the purpose of this test method,anelongated particle having a length greater than 5 m, a widthless
14、than 3 m, and an aspect ratio equal to or greater than 5:1.1This test method is under the jurisdiction of ASTM Committee D22 on AirQuality and is the direct responsibility of Subcommittee D22.04 on Workplace AirQuality.Current edition approved Oct. 1, 2011. Published October 2011. Originallyapproved
15、 in 1996. Last previous edition approved in 2006 as D6057 - 96 (2006).DOI: 10.1520/D6057-96R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Documen
16、t Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.4 man-made mineral fiber, nany inorganic fibrousmaterial produced by chemical or physical processes.3.1.5 single-crystal ceramic whisker, n a man-m
17、ade min-eral fiber that has a single-crystal structure.3.2 For definitions of other terms used in this test method,see Terminology D1356.4. Summary of Test Method4.1 The sample is collected on a mixed cellulose ester(MCE) filter by drawing air, using a sampling pump, throughan open-face 25-mm electr
18、ically conductive sampling cassetteassembly (1,2).3Asection of the opaque filter is converted intoan optically transparent homogeneous specimen using anacetone vaporizer. The fibers are counted by PCM at amagnification of approximately 4003 using the criteria dis-cussed in Section 11. Results are ex
19、pressed as a fiber concen-tration per unit volume of air and a fiber loading per unit areaof filter. The airborne concentration is expressed as fibers permillilitre (f/mL) and the fiber loading is expressed as fibers persquare millimetre (f/mm2).5. Significance and Use5.1 The SCCWmay be present in t
20、he workplace atmospherewhere these materials are manufactured, processed, trans-ported, or used. This test method can be used to monitorairborne concentrations of fibers in these environments. It maybe employed as part of a personal or area monitoring strategy.5.2 This test method is based on dimens
21、ional considerationsonly.As such, it does not provide a positive identification of thefibers counted. Analysis by SEM or TEM is required whenadditional fiber identification information is needed.NOTE 1This test method assumes that the analyst is familiar with theoperation of PCM instrumentation and
22、the interpretation of data obtainedusing this technique.5.3 This test method is not appropriate for measurement offibers with diameters less than approximately 0.25 m due tovisibility limitations associated with PCM. The SEM or TEMmethods may be used to provide additional size information ofSCCW if
23、needed (refer to Practice D6058 for additionalinformation on the use of these methods).5.4 Results from the use of this test method shall be reportedalong with 95 % confidence limits for the samples beingstudied. Individual laboratories shall determine their intralabo-ratory coefficient of variation
24、 and use it for reporting 95 %confidence limits (1,3,4).6. Interferences6.1 All fibers meeting the dimensional criteria in Section 3are not necessarily of the same composition. Since the PCMmethod does not differentiate based on chemistry or morphol-ogy, all fibers in accordance with the definitions
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6057199620115000STANDARDTESTMETHODFORDETERMININGCONCENTRATIONOFAIRBORNESINGLECRYSTALCERAMICWHISKERSINTHEWORKPLACEENVIRONMENTBYPHASECONTRASTMICROSCOPYPDF

链接地址:http://www.mydoc123.com/p-521412.html