ASTM D6024 D6024M-2016 red 6109 Standard Test Method for Ball Drop on Controlled Low Strength Material (CLSM) to Determine Suitability for Load Application《用球落在可控制的低强度材料上的方法测定荷载适用性.pdf
《ASTM D6024 D6024M-2016 red 6109 Standard Test Method for Ball Drop on Controlled Low Strength Material (CLSM) to Determine Suitability for Load Application《用球落在可控制的低强度材料上的方法测定荷载适用性.pdf》由会员分享,可在线阅读,更多相关《ASTM D6024 D6024M-2016 red 6109 Standard Test Method for Ball Drop on Controlled Low Strength Material (CLSM) to Determine Suitability for Load Application《用球落在可控制的低强度材料上的方法测定荷载适用性.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6024/D6024M 15D6024/D6024M 16Standard Test Method forBall Drop on Controlled Low Strength Material (CLSM) toDetermine Suitability for Load Application1This standard is issued under the fixed designation D6024/D6024M; the number immediately following the designation indicates theyear of
2、 original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method explains the determination of the abilit
3、y of Controlled Low Strength Material (CLSM) to withstand loadingby repeatedly dropping a metal weight onto the in-place material.1.2 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in PracticeD6026.1.2.1 The procedures used to speci
4、fy how data are collected/recorded and calculated in the standard are regarded as the industrystandard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do notconsider material variation, purpose for obtaining the data, special pur
5、pose studies, or any considerations for the users objectives;and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations.It is beyond the scope of these test methods to consider significant digits used in analysis methods for engin
6、eering data.1.3 UnitsThe values stated in either SI units or inch-pound units presented in brackets are to be regarded separately asstandard. The values stated in each system shall be used independently of the other. Combining values from the two systems mayresult in non-conformance with the standar
7、d.1.4 CLSM is also known as flowable fill, controlled density fill, soil-cement slurry, soil-cement grout, unshrinkable fill,“K-Krete,” and other similar names.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the us
8、er of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. (WarningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin andtissue upon prolonged exposure.2)2. Referenced Documents2.
9、1 ASTM Standards:3C125 Terminology Relating to Concrete and Concrete AggregatesD653 Terminology Relating to Soil, Rock, and Contained FluidsD3740 Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used inEngineering Design and ConstructionD4832 Te
10、st Method for Preparation and Testing of Controlled Low Strength Material (CLSM) Test CylindersD6023 Test Method for Density (Unit Weight), Yield, Cement Content, and Air Content (Gravimetric) of ControlledLow-Strength Material (CLSM)D6026 Practice for Using Significant Digits in Geotechnical DataD6
11、103 Test Method for Flow Consistency of Controlled Low Strength Material (CLSM) (Withdrawn 2013)43. Terminology3.1 DefinitionsFor definitions of common technical terms in this test method, refer to Terminology standards C125 and D653.3.1 Definitions of Terms Specific to This Standard:Definitions:1 T
12、his test method is under the jurisdiction of ASTM Committee D18 on Soil and Rock and is the direct responsibility of Subcommittee D18.15 on Stabilization WithAdmixtures.Current edition approved July 1, 2015Dec. 1, 2016. Published July 2015January 2017. Originally approved in 1995. Last previous edit
13、ion approved in 20072015 asD6024 07. DOI: 10.1520/D6024_D6024M-15.10.1520/D6024_D6024M-16.2 Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, Vol. 04.02.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer
14、Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.4 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provid
15、e the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the st
16、andard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.1 For definitions of common technical terms in
17、this test method, refer to Terminology standards C125 and D653.3.1.2 Controlled Low Strength Material (CLSM), na mixture of soil, aggregates (sand, gravel, or both), cementitiousmaterials, potable water, and sometimes admixtures, that hardens into a material with a higher strength than the soil, but
18、 less than8400 kPa 1200 psi.3.1.2.1 DiscussionUsed as a replacement for compacted backfill, CLSM can be placed as a slurry, a mortar, or a compacted material and typicallyhas strengths of 350 to 700 kPa 50 to 100 psi for most applications.4. Summary of Test Method4.1 A half spherical weight is dropp
19、ed five times from a specific height onto the surface of in-place CLSM. The diameter ofthe resulting indentation is measured and compared to established criteria. The indentation is inspected for any free water broughtto the surface from the impact.5. Significance and Use5.1 This test method is used
20、 primarily as a field test to determine the readiness of the CLSM to accept loads prior to addinga temporary or permanent wearing surface.5.2 This test method is not meant to predict the load bearing strength of a CLSM mixture.5.3 This test is one of a series of quality control tests that can be per
21、formed on CLSM during construction to monitor compliancewith specification requirements. The other tests that can be used during construction control are Test Methods D4832, D6023, andD6103.NOTE 1The quality of the result produced by this standard is dependent on the competence of the personnel perf
22、orming it, and the suitability of theequipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objectivetesting/sampling/inspection/and the like. Users of this standard are cautioned that compliance with Practice D3740 does not
23、 in itself assure reliable results.Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.6. Apparatus6.1 Ball-drop ApparatusA Ball Penetration Apparatus (Kelly Ball) that consists of a half sphere with a handle, togetherweighing 14-15 kg 30-33 l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6024D6024M2016RED6109STANDARDTESTMETHODFORBALLDROPONCONTROLLEDLOWSTRENGTHMATERIALCLSMTODETERMINESUITABILITYFORLOADAPPLICATION

链接地址:http://www.mydoc123.com/p-521328.html