ASTM D6007-2014 0330 Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber《采用小型腔室测定空气中木制品的甲醛浓度的标准试验方法》.pdf
《ASTM D6007-2014 0330 Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber《采用小型腔室测定空气中木制品的甲醛浓度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6007-2014 0330 Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber《采用小型腔室测定空气中木制品的甲醛浓度的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6007 14Standard Test Method forDetermining Formaldehyde Concentrations in Air fromWood Products Using a Small-Scale Chamber1This standard is issued under the fixed designation D6007; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method measures the formaldehyde concentra-tions in air emitted by wood product te
3、st specimens underdefined test conditions of temperature and relative humidity.Results obtained from this small-scale chamber test method areintended to be comparable to results obtained from testinglarger product samples by the large chamber test method forwood products,ASTM Test Method E1333. The
4、results may becorrelated to values obtained from ASTM Test Method E1333.The quantity of formaldehyde in an air sample from the smallchamber is determined by a modification of NIOSH 3500chromotropic acid test procedure. As with ASTM Test MethodE1333, other analytical procedures may be used to determi
5、nethe quantity of formaldehyde in the air sample provided thatsuch methods give results comparable to those obtained byusing the chromotropic acid procedure. However, the testresults and test report must be properly qualified and theanalytical procedure employed must be accurately described.1.2 The
6、wood-based panel products to be tested by this testmethod are characteristically used for different applicationsand are tested at different relative amounts or loading ratios toreflect different applications. This is a test method that specifiestesting at various loading ratios for different product
7、 types.However, the test results and test report must be properlyqualified and must specify the make-up air flow, samplesurface area, and chamber volume.1.3 Ideal candidates for small-scale chamber testing areproducts relatively homogeneous in their formaldehyde releasecharacteristics. Still, produc
8、t inhomogeneities must be consid-ered when selecting and preparing samples for small-scalechamber testing.1.4 The values stated in SI units are the standard values.Any values given in parentheses are for information only.1.5 This standard does not purport to address all of thesafety concerns, if any
9、, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D3195 Practice for Rotameter CalibrationD5197 Test
10、Method for Determination of Formaldehyde andOther Carbonyl Compounds inAir (Active Sampler Meth-odology)D5221 Test Method for Continuous Measurement of Form-aldehyde in Air (Withdrawn 1997)3E77 Test Method for Inspection and Verification of Ther-mometersE220 Test Method for Calibration of Thermocoup
11、les ByComparison TechniquesE337 Test Method for Measuring Humidity with a Psy-chrometer (the Measurement of Wet- and Dry-Bulb Tem-peratures)E691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE741 Test Method for Determining Air Change in a SingleZone by M
12、eans of a Tracer Gas DilutionE1333 Test Method for Determining Formaldehyde Concen-trations in Air and Emission Rates from Wood ProductsUsing a Large Chamber2.2 U.S. Department of Housing and Urban DevelopmentStandard:4HUD 24 CFR 3280, Manufactured Home Construction andSafety Standards1This test met
13、hod is under the jurisdiction of ASTM Committee D07 on Woodand is the direct responsibility of Subcommittee D07.03 on Panel Products.Current edition approved Oct. 1, 2014. Published December 2014. Originallyapproved in 1996. Last previous edition approved in 2008 as D6007 02 (2008).DOI: 10.1520/D600
14、7-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard i
15、s referenced onwww.astm.org.4Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov; request Federal Register, Vol 49, No. 155, Aug. 8, 1984Copyright ASTM International, 100 Barr Harbor Drive,
16、PO Box C700, West Conshohocken, PA 19428-2959. United States12.3 National Institute for Occupational Safety and HealthStandard:NIOSH 3500 Formaldehyde Method52.4 Other Documents:Minnesota Statutes Sections 144.495, 325f.18, and325F.181Formaldehyde Gases in Building Materials6California Air Resources
17、 Board (CARB) California Code ofRegulations sections 93120-93120.12, title 17, AirborneToxic Control Measure to Reduce Formaldehyde Emis-sions from Composite Wood Products3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 air change rate, (Q/V): the ratio of the conditionedand fi
18、ltered air, Q, that enters or is replaced in the smallchamber in one hour divided by the interior volume of thesmall chamber, V, air changes per hour (ACH).3.1.2 loading ratio, L: (L = A/V) , the total exposed surfacearea (A), excluding panel edges, of the product being testeddivided by the test cha
19、mbers interior volume, V,inm2/m3.3.1.3 make-up air flow, Q: the quantity of conditioned andfiltered air fed into the chamber per unit time, m3/h. Q can bedetermined by taking the Q/A value from Table 1 and dividingby A.3.1.4 Q/A ratio: the ratio of air flow through the chamber(Q) to sample surface a
20、rea (A), m3/h air per m2test area (seeSection 8, Table 1)3.1.5 sample surface area, A: the total area of all samplefaces exposed in the chamber, m2.3.1.6 steady state concentration, Cs: the formaldehyde con-centration (expressed in parts of formaldehyde per millionparts air (ppm) under the defined e
21、nvironmental test parametersof this method.3.1.7 volume of closed system, V: the interior volume of thetest chamber, m3.4. Significance and Use4.1 Upper limits for the formaldehyde emission rates havebeen established for wood panel building products made withurea-formaldehyde adhesives and permanent
22、ly installed inhomes or used as components in kitchen cabinets and similarindustrial products. This test method is intended for use inconjunction with the test method referenced by HUD 24 formanufactured housing and by Minnesota Statutes for housingunits and building materials. This method may also
23、be used formonitoring products for compliance to the California AirResources Board (CARB) regulation for composite woodproducts. This test method provides a means of testing smallersamples and reduces the time required for testing.4.2 Formaldehyde concentration levels obtained by thissmall-scale met
24、hod may differ from expected in full-scaleindoor environments. Variations in product loading,temperature, relative humidity, and air exchange will affectformaldehyde emission rates and thus likely indoor air form-aldehyde concentrations.4.3 This test method requires the use of a chamber of 0.02to1m3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD600720140330STANDARDTESTMETHODFORDETERMININGFORMALDEHYDECONCENTRATIONSINAIRFROMWOODPRODUCTSUSINGASMALLSCALECHAMBER

链接地址:http://www.mydoc123.com/p-521285.html