《ASTM D6007-2002 Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale Chamber《用小型室测定空气中来自木制品的甲醛浓度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6007-2002 Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale Chamber《用小型室测定空气中来自木制品的甲醛浓度的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6007 02Standard Test Method forDetermining Formaldehyde Concentration in Air from WoodProducts Using a Small Scale Chamber1This standard is issued under the fixed designation D 6007; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method measures the formaldehyde concentra-tions in air from wood products under
3、 defined test conditions oftemperature and relative humidity. Results obtained from thissmall-scale chamber test method are intended to be comparableto results obtained testing larger product samples by the largechamber test method for wood products, Test Method E 1333.The results may be correlated
4、to values obtained from TestMethod E 1333. The quantity of formaldehyde in an air samplefrom the small chamber is determined by a modification of theNational Institute for Occupational Safety and Health (NIOSH)3500 chromotropic acid test procedure. Other analytical pro-cedures may be used to determi
5、ne the quantity of formaldehydein the air sample provided that such methods give resultscomparable to those obtained by using the chromotropic acidprocedure. However, the test results and test report must beproperly qualified and the analytical procedure employed mustbe accurately described.1.2 The
6、wood-based panel products to be tested by this testmethod are characteristically used for different applicationsand are tested at different relative amounts or loading ratios toreflect different applications. This is a test method that specifiestesting at various loading ratios for different product
7、 types.However, the test results and test report must be properlyqualified and must specify the make-up air flow, samplesurface area, and chamber volume.1.3 Ideal candidates for small-scale chamber testing areproducts relatively homogeneous in their formaldehyde releasecharacteristics. Still, produc
8、t inhomogeneities must be consid-ered when selecting and preparing samples for small-scalechamber testing.1.4 The values stated in SI units are the standard values.Any values given in parentheses are for information only.1.5 This standard does not purport to address all of thesafety concerns, if any
9、, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 3195 Practice for Rotameter Calibration2D 5197 Tes
10、t Method for Determination of Formaldehydeand Other Carbonyl Compounds in Air (Active SamplerMethodology)2D 5221 Test Method for Continuous Measurement of Form-aldehyde in Air2E 77 Test Methods for Inspection and Verification of Ther-mometers3E 220 Method for Calibration of Thermocouples by Com-pari
11、son Techniques3E 337 Test Method for Measuring Humidity with a Psy-chrometer (the Measurement of Wet-Bulb and Dry-BulbTemperatures)2E 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method4E 741 Test Method for Determining Air Change in a SingleZone by Means
12、of Tracer Gas Dilution5E 1333 Test Method for Determining Formaldehyde Con-centrations in Air and Emission Rates from Wood ProductsUnder Defined Test Conditions Using a Large Chamber62.2 U.S. Department of Housing and Urban Development(HUD) Standards:24 CFR 3280, Manufactured Home Construction and S
13、afetyStandards72.3 NIOSH Standard:3500 Formaldehyde Method82.4 Other Documents:Minnesota Statutes Section 144.495, 325f.18, and 325F.181Formaldehyde Gases in Building Materials91This test method is under the jurisdiction of ASTM Committee D07 on Woodand is the direct responsibility of Subcommittee D
14、07.03 on Panel Products.Current edition approved April 10, 2002. Published June 2002. Originallypublished as D 6007 - 96. Last previous edition D 6007 - 96.2Annual Book of ASTM Standards, Vol 11.03.3Annual Book of ASTM Standards, Vol 14.03.4Annual Book of ASTM Standards, Vol 14.02.5Annual Book of AS
15、TM Standards, Vol 04.11.6Annual Book of ASTM Standards, Vol 04.10.7Federal Register, Vol 49, No. 155, Aug. 8, 1984, available from Superintendentof Documents, U.S. Government Printing Office, 732 N. Capitol St., NW, Mail Stop:SDE, Washington, DC 20401.8U.S. Dept. of Health and Human Services, 1989,
16、available from Superintendentof Documents, U.S. Government Printing Office, 732 N. Capitol St., NW, Mail Stop:SDE, Washington, DC 20401.9Available from Print Communications, Dept. of Administration, 117 UniversityAve., St. Paul, MN 55155.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C
17、700, West Conshohocken, PA 19428-2959, United States.3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 air change rate, N (N is equal to Q/V)the ratio ofconditioned and filtered air that enters or is replaced in thesmall chamber in one hour divided by the interior volume ofthe s
18、mall chamber, air changes per hour (ACH).3.1.2 equilibrium concentration, Ceqis that Csmeasuredwhen Qequals zero, ppm.3.1.3 loading ratio, L(L is equal to A/V) the total exposedsurface area, excluding panel edges, of the product being testeddivided by the test chambers interior volume, m2/m3.3.1.4 m
19、ake-up air flow, Qthe quantity of conditioned andfiltered air fed into the chamber per unit time, m3/h.3.1.5 mass transfer coeffcient, Ka measure of the perme-ability of the emitting surface of a wood based panel product,m/h. Kis calculated as follows:10K 5Q/A!Cs!Ceq2 Cs!(1)3.1.6 N/L ratio(N/L is eq
20、uivalent to Q/A) the ratio of airflow through the chamber to sample surface area, m/h, asfollows:N/L 5Q/VA/V5 Q/V! 3 V/A! 5 Q/A (2)3.1.7 Q/A ratiothe ratio of air flow through the chamber(Q) to sample surface area ( A), m/h.3.1.8 sample surface area, Athe total area of all samplefaces exposed in the
21、 chamber, m2.3.1.9 steady state concentration, Csthe interval when theformaldehyde concentration is not changing with time (ex-pressed in parts of formaldehyde per million parts air (ppm)under the defined environmental test parameters.3.1.10 volume of closed system, Vthe interior volume ofthe test c
22、hamber, m3.4. Significance and Use4.1 Limitations on formaldehyde levels have been estab-lished for wood panel building products made with urea-formaldehyde adhesives and permanently installed in homes orused as components in kitchen cabinets and similar industrialproducts. This test method is inten
23、ded for use in conjunctionwith the test method referenced by HUD Rules and Regula-tions 24 CFR 3280 for manufactured housing and by Minne-sota Statutes Section 144.495 for housing units and buildingmaterials. This test method provides a means of testing smallersamples and reduces the time required f
24、or testing.4.2 Formaldehyde concentration levels obtained by thissmall-scale method may differ from expected in full-scaleindoor environments. Variations in product loading, tempera-ture, relative humidity, and air exchange will affect formalde-hyde emission rates and thus likely indoor air formalde
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD60072002STANDARDTESTMETHODFORDETERMININGFORMALDEHYDECONCENTRATIONINAIRFROMWOODPRODUCTSUSINGASMALLSCALECHAMBER

链接地址:http://www.mydoc123.com/p-521283.html