ASTM D5957-1998(2005) Standard Guide for Flood Testing Horizontal Waterproofing Installations《测试横向抗洪防水装置的标准指南》.pdf
《ASTM D5957-1998(2005) Standard Guide for Flood Testing Horizontal Waterproofing Installations《测试横向抗洪防水装置的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5957-1998(2005) Standard Guide for Flood Testing Horizontal Waterproofing Installations《测试横向抗洪防水装置的标准指南》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5957 98 (Reapproved 2005)Standard Guide forFlood Testing Horizontal Waterproofing Installations1This standard is issued under the fixed designation D 5957; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides the user with a method for testingthe watertightness of waterproofing installations applied tohor
3、izontal surfaces having a slope not greater than 20 mm/m(2 % slope) (14 in. per ft).1.2 This guide is intended for waterproofing installation onparking garages and plaza deck type applications over habit-able spaces or on elevated structures, but is not intended for useon building roofing systems. A
4、pplicable waterproofing mem-brane installations that may be tested using this guide are fullyadhered or bonded sheet membranes, liquid or fluid appliedmembranes, or loose laid sheet membranes.1.3 The procedures presented here are not intended for useon those waterproofing installation applications t
5、hat are forlong-term water storage or continuously submerged environ-ments, such as swimming pools, fountains, tank liners withhydrostatic pressure, or water storage units (storage periodgreater than 48 h).1.4 The values stated in SI units are to be regarded as thestandard. The values given in paren
6、theses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitatio
7、ns prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1079 Terminology Relating to Roofing, Waterproofing,and Bituminous Materials2.2 ACI Document:ACI 515 Guide to the Use of Waterproofing, Dampproofing,Protective, and Decorative Barrier Systems for Concrete33. Terminology3.1 For definitions
8、of terms relating to roofing and water-proofing, see Terminology D 1079.3.2 Definition of Term Specific to This Standard:3.2.1 sacrificial sheeta material used to form a temporaryseal between a containment assembly and the waterproofingsystem. The material used for a sacrificial sheet shall not caus
9、edamage nor be detrimental to the primary system.4. Summary of Guide4.1 This guide uses a series of temporary containmentassemblies of pond water on horizontal surfaces to determinethe watertightness of waterproofing installations.4.2 The area to be tested is subdivided as required by thecontainment
10、 assemblies, and drains within the subdivided areaare temporarily blocked to prevent water leakage into thedrainage system.4.3 Water is ponded in the subdivided area and maintainedfor a minimum period of 24 h. The space below the testlocation is monitored for leakage during the test period.5. Signif
11、icance and Use5.1 This guide describes the techniques used to test forwatertightness of waterproofing installations on horizontalservices having a slope not greater than 20 mm/m (2 % slope)(14 in./ft). See also ACI 515.5.2 The structural capacity of the substrate to which thewaterproofing system is
12、to be installed should be reviewed bya licensed structural engineer to verify that the loads associatedwith the use of procedures described in this guide do notexceed code and design restrictions. Lateral loads will beimposed on curbs or walls used for containment of the waterduring the test procedu
13、res and their effect should be accounted1This guide is under the jurisdiction of ASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.22 on Water-proofing and Damproofing Systems.Current edition approved July 1, 2005. Published July 2005. Originally app
14、rovedin 1996. Last previous edition approved in 1998 as D 5957 98.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM web
15、site.3Available from American Concrete Institute (ACI), P.O. Box 9094, FarmingtonHills, MI 48333.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.for. The effects of equipment, planters, or other movableobjects present within the test
16、 area should be considered.NOTE 1Potable water weighs approximately 1000 kg/cubic m (62.3 lbper cubic ft) at 22C (71.6F) or 1 g/cm2/cm depth (5.19 lbs/ft2per in.depth).5.3 This guide describes a procedure to test for watertight-ness of waterproofing installations under ponded water with ashort-term
17、hydrostatic head measuring not more than 100 mm(4 in.).NOTE 2Increasing the amount of water forming a hydrostatic headbeyond 100 mm (4 in.) of water may be considered provided the impactof increased loads on the substrate has been reviewed and approved by alicensed structural engineer.5.4 For the pu
18、rposes of this guide, the installation of thewaterproofing membrane and flashing should be completed andthe materials fully cured. Manufacturers should specify aminimum time period for materials to cure prior to performingflood test, however, no testing should be performed during thefirst 24 h follo
19、wing installation of system materials (48 h minif materials are installed at a time when ambient temperaturesare below 10C (50F).5.5 The additional loads imposed upon the structure duringthe test period will affect the deflection of structural items. Theeffects shall be analyzed by a licensed struct
20、ural engineer priorto placement of additional loads. Critical locations shall bemonitored during the duration of the test period.5.6 This guide is not recommended to be used if freezingtemperatures are expected to occur during the test period.Ponded water can freeze and become adhered to the water-p
21、roofing system resulting in pulling or tearing of the flashingsaway from the substrate or may break interior corners.5.7 The intent of this guide is to provide a measure ofconfidence of the waterproofing installation to remain water-tight for the service life of the system, based upon the observedpe
22、rformance of the system under ponded water for a limitedperiod of time.6. Materials6.1 Drain PlugsPneumatically inflatable devices consist-ing of a rubber ball, draw chain and ring, and preset, built-inpressure relief valve; compression plugs having a screwmechanism; or other standard plumbing fixtu
23、res.6.2 Standard Air Pressure Hand Pump with HosePressuregage is optional.6.3 Vertical-Sided Shallow Pan.6.4 Containment AssembliesAssemblies to form tempo-rary dams can be constructed using one or more of thefollowing materials. Refer to Figs. 1-4, for examples ofconstructed containment assemblies.
24、6.4.1 Nominal 50-mm (2-in.) thick by 100 or 150-mm (4 or6-in.) wide wood members,6.4.2 Polyethylene film having a minimum thickness of 6mils,6.4.3 Sandbags,6.4.4 Duct tape,6.4.5 Waterproofing membrane materials,6.4.6 Adhesives and sealants,6.4.7 Scale or similar measuring device, and6.4.8 Extruded o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD595719982005STANDARDGUIDEFORFLOODTESTINGHORIZONTALWATERPROOFINGINSTALLATIONS 测试 横向 抗洪 防水 装置 标准 指南

链接地址:http://www.mydoc123.com/p-521122.html