《ASTM D5955-2002(2007) Standard Test Methods for Estimating Contribution of Environmental Tobacco Smoke to Respirable Suspended Particles Based on UVPM and FPM《基于粒子紫外线吸收法(UVPM)和粒子荧光.pdf》由会员分享,可在线阅读,更多相关《ASTM D5955-2002(2007) Standard Test Methods for Estimating Contribution of Environmental Tobacco Smoke to Respirable Suspended Particles Based on UVPM and FPM《基于粒子紫外线吸收法(UVPM)和粒子荧光.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5955 02 (Reapproved 2007)Standard Test Methods forEstimating Contribution of Environmental Tobacco Smoketo Respirable Suspended Particles Based on UVPM andFPM1This standard is issued under the fixed designation D 5955; the number immediately following the designation indicates the yea
2、r oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods pertain to the sampling/analysis of
3、respirable suspended particles (RSP) and the estimation of theRSP fraction attributable to environmental tobacco smoke(ETS). These test methods are based on collection of total RSPon a membrane filter, extracting the collected material inmethanol, and measuring total ultraviolet absorbance or fluo-r
4、escence, or both, of this extract. The corresponding methodsof estimation are termed ultraviolet particulate matter (UVPM)and fluorescent particulate matter (FPM), respectively.1.2 These test methods are compatible with, but do notrequire the determination of solanesol, which is also used toestimate
5、 the contribution of ETS to RSP (see Test MethodD 6271).1.3 The sampling components consist of a preweighed,1.0-m pore size polytetrafluoroethylene (PTFE) membranefilter in a filter cassette connected on the inlet end to a particlesize separating device and, on the outlet end, to a samplingpump. The
6、se test methods are applicable to personal and areasampling.1.4 These test methods are limited in sample duration onlyby the capacity of the membrane filter (about 2000 g). Thesetest methods have been evaluated up to a 24-h sample durationwith a minimum sample duration of at least 1 h.1.5 Limits of
7、detection (LOD) and quantitation (LOQ) forthe UVPM test method at a sampling rate of 2 L/min are,respectively, 2.5 g/m3and 8.3 g/m3for a 1-h sample durationand 0.3 g/m3and 1.0 g/m3for an 8-h sample duration. TheLOD and LOQ for the FPM test method at a sampling rate of2 L/min are, respectively, 1.4 g
8、/m3and 4.7 g/m3for a 1-hsample duration and 0.2 g/m3and 0.6 g/m3for an 8-h sampleduration.1.6 The values stated in SI units are to be regarded asstandard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of t
9、his standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary information is given in 13.6.2. Referenced Documents2.1 ASTM Standards:2D 1356 Terminology Relating to Sampling and Analysis ofAtmospher
10、esD 1357 Practice for Planning the Sampling of the AmbientAtmosphereD 3631 Test Methods for Measuring Surface AtmosphericPressureD 5337 Practice for Flow Rate Calibration of PersonalSampling PumpsD 6271 Test Method for Estimating Contribution of Envi-ronmental Tobacco Smoke to Respirable Suspended P
11、ar-ticles Based on Solanesol3. Terminology3.1 DefinitionsFor definitions of terms used in these testmethods, refer to Terminology D 1356.3.2 Definitions of Terms Specific to This Standard:3.2.1 environmental tobacco smoke (ETS)an aged, dilutecomposite of exhaled tobacco smoke (exhaled mainstreamsmok
12、e) and smoke from tobacco products (sidestream smoke).3.2.2 environmental tobacco smoke particulate matter(ETS-PM)the particulate phase of ETS.3.2.3 fluorescent particulate matter (FPM)an estimationof the contribution of ETS particulate matter to RSP obtainedby comparing the fluorescence intensity o
13、f the RSP sample tothat of a surrogate standard.3.2.4 respirable suspended particles (RSP)particleswhich, when captured by a size-selective sampling device,conform to a collection efficiency curve with a median cutpointat an aerodynamic diameter of 4.0 m (1).31These test methods are under the jurisd
14、iction of ASTM Committee D22 on AirQuality and are the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved April 1, 2007. Published June 2007. Originallyapproved in 1996. Last previous edition approved in 2002 as D 5955 - 02.2For referenced ASTM standards, visit the A
15、STM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The boldface numbers in parentheses refer to the list of references at the end ofthis standard.1Copyrig
16、ht ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.5 surrogate standarda chemical whose concentrationhas been related quantitatively to a known concentration ofETS-PM.3.2.6 2,28,4,48-tetrahydroxybenzophenone (THBP)aUVPM surrogate standard.3
17、.2.7 ultraviolet particulate matter (UVPM)an estimationof the contribution of ETS particulate matter to RSP obtainedby comparing the ultraviolet absorbance of the RSP sample tothat of a surrogate standard.4. Summary of Test Methods4.1 A known volume of air is drawn through an inertialimpactor or cyc
18、lone assembly separating at 4.0 m to separateRSP from total suspended particulate matter and then througha filter assembly. The respirable suspended particulate matter iscollected on a PTFE membrane filter contained within the filterassembly.4.2 The weight of RSP is determined as the differencebetwe
19、en the filter weight before and after collection. Theconcentration of RSP (g/m3) is calculated from the RSPweight and volume of air sampled.4.3 The filter is extracted with methanol in a 4-mL glassvial.4.4 An aliquot of the extract is injected into a columnlesshigh performance liquid chromatography
20、(HPLC) systemequipped with an ultraviolet detector (325 nm) and a fluores-cence detector (300-nm excitation; 420-nm emission) con-nected in series. (Alternatively, absorbance and fluorescencemay be measured with bench-top spectrophotometers.)4.5 The area of the resulting UV peak is compared to areas
21、obtained from the injection of standard solutions of THBP (asurrogate standard for ETS-PM). The area of the resultingfluorescence peak is compared to areas obtained from theinjection of standard solutions of scopoletin (a surrogatestandard for ETS-PM). The results, which are estimates of thecontribu
22、tion of ETS-PM to RSP, are reported as UVPM andFPM, respectively.5. Significance and Use5.1 Environmental tobacco smoke consists of both vapor-and particle-phase components. Due to the nature of vapor andparticulate phases, they rarely correlate well, and an accurateassessment of ETS levels in indoo
23、r air requires determininggood tracers of both phases. Among the attributes of an idealETS tracer, one critical characteristic is that the tracer should“remain in a fairly consistent ratio to the individual contami-nant of interest or category of contaminants of interest (forexample, suspended parti
24、culates) under a range of environmen-tal conditions.” (2). The UVPM and FPM fulfill this require-ment, staying in a constant ratio to RSP from tobacco smokeunder a variety of ventilation conditions and sampling dura-tions. Solanesol (a C45isoprenoid alcohol specific to tobacco),determined in accorda
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD595520022007STANDARDTESTMETHODSFORESTIMATINGCONTRIBUTIONOFENVIRONMENTALTOBACCOSMOKETORESPIRABLESUSPENDEDPARTICLESBASEDONUVPMANDFPM

链接地址:http://www.mydoc123.com/p-521119.html