ASTM D5897-1996(2007) Standard Test Method for Determination of Percent Hydroxyl on Cellulose Esters by Potentiometric Titration-Alternative Method《电位滴定转换法测定纤维素酯中羟基百分率的标准试验方法》.pdf
《ASTM D5897-1996(2007) Standard Test Method for Determination of Percent Hydroxyl on Cellulose Esters by Potentiometric Titration-Alternative Method《电位滴定转换法测定纤维素酯中羟基百分率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5897-1996(2007) Standard Test Method for Determination of Percent Hydroxyl on Cellulose Esters by Potentiometric Titration-Alternative Method《电位滴定转换法测定纤维素酯中羟基百分率的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5897 96 (Reapproved 2007)Standard Test Method forDetermination of Percent Hydroxyl on Cellulose Esters byPotentiometric TitrationAlternative Method1This standard is issued under the fixed designation D 5897; the number immediately following the designation indicates the year oforigina
2、l adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure for determining thepercent hy
3、droxyl on cellulose esters by potentiometric titration.The typical range of percent hydroxyl measured is 0.7 to10.0 %.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesa
4、fety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 817 Test Methods of Testing
5、Cellulose Acetate Propi-onate and Cellulose Acetate ButyrateD 871 Test Methods of Testing Cellulose Acetate3. Summary of Test Method3.1 The cellulose ester is dissolved in pyridine and thehydroxyl sites on the cellulose ester are acetylated with aceticanhydride in the presence of basic catalyst, 1-m
6、ethylimidazole.The excess acetic anhydride is hydrolyzed and the resultingacetic acid is titrated with sodium hydroxide. An automatictitrator dispenses the titrant, potentiometrically determines theendpoint, and calculates the percent hydroxyl on the celluloseester based on a blank determination.4.
7、Significance and Use4.1 This test method provides a simpler means for thedetermination of the hydroxyl content of cellulose esters thanthe preparation and measurement of the carbanilate derivativedescribed in Test Methods D 817 and D 871.4.2 The hydroxyl content is an important indicator ofsolubilit
8、y and reactivity.5. Interferences5.1 Undissolved ester may accumulate on the sides of theflask and on top of the stirring-star during dissolution, leadingto low results. Gently swirling the solution during titration canreduce this problem.5.2 The ground glass joints of the flask and the air con-dens
9、er must always be rinsed into the flask with hydrolyzingsolution at the point of hydrolysis and before titration. This willprevent erroneous results from material that may have refluxedinto the joint.6. Apparatus6.1 Titrator,3equipped with Glass Electrode, or equivalent.6.2 Heating/Stirring Module,
10、six-place.6.3 Heating/Stirring Block, cut from polished-finish alumi-num block to fit stirrer in 7.2 (see Fig. 1 for dimensions).6.4 Stirrer, six place.6.5 Magnetic Stirrers, size 25 mm and 50 mm.6.6 Stirring Bar.6.7 Flask and Air Condenser, (see Fig. 2 for dimensions).6.8 Bottle-Top Dispensers, cap
11、able of dispensing 20 mL, 35mL, and 50 mL, or equivalent.6.9 Analytical Balance, capable of weighing 250 g to thefourth decimal place.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcomm
12、ittee D01.36 on Cellulose and Cellulose Derivatives.Current edition approved June 1, 2007. Published August 2007. Originallyapproved in 1996. Last previous edition approved in 2001 as D 5897 -96 (2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Serv
13、ice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Titrator and instruction manual such as Mettler DL77 equipped with DG-115-SC glass electrode available from Mettler Toledo Inc., 69 Princeton-Hightestown, P.O
14、. Box 71, Hightestown, NJ 08520 has been found suitable for thispurpose.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.10 Analytical Balance, capable of weighing 1000 g to thesecond decimal place.7. Reagents and Materials7.1 Purit
15、y of ReagentsAmerican Chemical Society4re-agent grade chemicals shall be used throughout this test unlessotherwise indicated.7.2 Pyridine.7.3 Acetic Anhydride.7.4 Acetylating Solution115 6 0.50 g of acetic anhydrideper litre of pyridine. The container needs to be equipped with20-mL buret. The shelf-
16、life of this solution is 5 days.7.5 Dimethylformamide.7.6 Deionized Water, purified to 18.3 MV resistance.7.7 Hydrolyzing SolutionMix 600 mL dimethylforma-mide, 300 mL pyridine, and 100 mL water in a 1-L bottleequipped with a bottle top dispenser capable of dosing 35 mL.Stir for at least 10 min prio
17、r to use. The shelf-life of thissolution is 1 month.7.8 1-Methylimidazole.7.9 Sucrose.7.10 Acetone.7.11 Potassium Acid Phthalate (KHP), National Institute ofStandards and Technology primary standard grade. Store indesiccator, after drying for1hat105C (65C).7.12 Methanol.7.13 Sodium Hydroxide, 0.5 N
18、in methanol. This solutionhas a shelf life of 2 weeks.7.14 Traceable Buffers, pH 4 and pH 7, available fromNational Institute of Standards and Technology.7.15 Potassium Chloride (KCl),5M, weigh 37.3 g(60.3000 g) of KCl into a 100-mL volumetric flask. Dilute tothe mark with purified water. Shake into
19、 solution.7.16 1,2-Dichloroethane.8. Calibration and Standardization8.1 Calibration of the Electrode:NOTE 1If the electrode is new, perforate the nipple on the rubber capand soak the electrode in 5 M potassium chloride for 1 h. Store in pH 4buffer until use.8.1.1 Select from the titrator menu the pr
20、ocedure for cali-bration of the electrode.8.1.2 Add about 50 mL of pH 4 buffer into a titration cupand lower the electrode into it.4Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the Ameri
21、can Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.FIG. 1 Heating/Stirring Block DimensionsFIG. 2 Flask and Air Condensor DimensionsD 589
22、7 96 (2007)28.1.3 Run the procedure for the titrator to read the correctpH.8.1.4 Repeat process 9.1.1-9.1.3 for buffer pH 7.8.1.5 Make sure that the calibration is done when a newelectrode is put into use and then check once/month thereafteror when a problem is suspected.8.2 Standardization of Metha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD589719962007STANDARDTESTMETHODFORDETERMINATIONOFPERCENTHYDROXYLONCELLULOSEESTERSBYPOTENTIOMETRICTITRATIONALTERNATIVEMETHOD

链接地址:http://www.mydoc123.com/p-520992.html