1、Designation: D 5702 07Standard Practice forField Sampling of Coating Films for Analysis for HeavyMetals1This standard is issued under the fixed designation D 5702; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a method to control the removal ofsamples of coating films from substrates for subsequent labo-ratory a
3、nalysis for heavy metal content on a mass basis. Thistechnique can be used in the field, the fabricating shop, orlaboratory.1.2 The values stated in SI units are to be regarded as thestandard. The values in parentheses are for information only.1.3 This standard does not purport to address all of the
4、safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardinformation, see Section 5, Note 1 and Note 3.2. Re
5、ferenced Documents2.1 ASTM Standards:2D 4138 Practices for Measurement of Dry Film Thicknessof Protective Coating Systems by Destructive, Cross-Sectioning MeansD 6132 Test Method for Nondestructive Measurement ofDry Film Thickness ofApplied Organic Coatings Using anUltrasonic GageD 7091 Practice for
6、 Nondestructive Measurement of DryFilm Thickness of Nonmagnetic Coatings Applied toFerrous Metals and Nonmagnetic, Nonconductive Coat-ings Applied to Non-Ferrous Metals3. Significance and Use3.1 Prior to beginning a project that involves the removal,cutting, grinding, or burning of paint, it is nece
7、ssary todetermine if the coating contains hazardous materials, such aslead, as certain requirements for worker and environmentalprotection may need to be imposed. The presence and quantityof hazardous materials in a paint can be determined throughlaboratory analysis; however, since the analysis is b
8、ased on theweight of the specimen, the removal of the sample must beproperly controlled to improve the reliability of the test results.The number and location of samples to be removed must alsobe determined to characterize properly the extent of thepresence of hazardous materials, if any, on a struc
9、ture.4. Materials and Equipment4.1 Sample Collection ContainerA clean plastic bag orrigid container comprised of a material such as polyethylenethat will not contaminate the sample.4.2 Straight Edge or Ruler.4.3 Knife or Chisel, cleaned and sharpened, for removingpaint samples.4.4 Dry Film Thickness
10、 Gage, for measuring total coatingthickness.5. Procedure5.1 Select a sufficient number of areas for coating removalthat properly characterize the coatings on the structure.5.1.1 Selection may be based on painting history, knowl-edge of previously applied coatings, prior touch-up and re-painting prog
11、rams, and other such factors.5.1.2 Select areas that properly characterize the range ofthickness found. Dry film thickness can be measured inaccordance with Test Methods D 4138, D 6132, or PracticeD 7091.5.1.3 Remove a minimum of three samples.5.2 At each sample site, clean the surface of dirt, dust
12、, ordebris.NOTE 1Hazardous materials can be present in surface debris andchalk which may be removed during cleaning. Thus, consideration shouldbe given to collecting this surface debris and chalk for analysis.5.3 At each sample site, use a knife and straight edge toscribe the perimeter of a square t
13、hrough the coating film to thesubstrate. The square should be of sufficient size to give a onegram sample.NOTE 2Paint with a density of 1.5 g/cm3and 250 microns (10 mils)thick will generate one gram of sample in a square that is 5 cm (2 in.) on1This practice is under the jurisdiction of ASTM Committ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD57022007STANDARDPRACTICEFORFIELDSAMPLINGOFCOATINGFILMSFORANALYSISFORHEAVYMETALS 重金属 分析 镀膜 现场 取样

链接地址:http://www.mydoc123.com/p-520451.html