1、Designation: D5642 16Standard Test Method forSealed Tube Chemical Compatibility Test1This standard is issued under the fixed designation D5642; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers procedures for evaluating theinteraction of electrical insulation components used, or in-tended to be used, in electrica
3、l insulation systems.1.2 This test method is useful for determining compatibilitybut additional testing will potentially be required for someapplications.1.3 This test method also provides useful information aboutthe behavior of selected insulating materials when compared toa reference value as oppo
4、sed to a reference system.1.4 This test method does not cover systems which operatein liquids or gases other than air.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesa
5、fety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See also 8.2.4,8.3.1 and 8.3.2.12. Referenced Documents2.1 ASTM Standard
6、s:2D149 Test Method for Dielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD1676 Test Methods for Film-Insulated Magnet WireD1711 Terminology Relating to Electrical Insulation3. Terminology3.1 Definitions:3.1.1 magnet wireSee Te
7、rminology D1711 for the defini-tion of this term.3.2 Definitions of Terms Specific to This Standard:3.2.1 aging test, na process of exposure, to a specified setof conditions for a defined period of time, which results in anirreversible change in one or more physical, chemical,electrical, or thermal
8、characteristics of a material.3.2.2 candidate system, nthe proposed electrical insula-tion system to be evaluated.3.2.3 electrical insulation system, nan intimate combina-tion of insulating materials with conductors, as used in elec-trical equipment.3.2.4 insulation system class, na standardized des
9、ignationof the temperature capability of the electrical insulation sys-tem. It is expressed by both numbers and letters as follows:System Class105 (A)120 (E)130 (B)155 (F)180 (H)200 (N)220 (R)240 (S)3.2.5 reference system, nan electrical insulation systemwhich has been previously evaluated and found
10、 acceptable.3.2.6 twisted pair, nfilm-insulated round magnet wire thathas been prepared in accordance with Test Methods D1676.4. Summary of Test Method4.1 Acombination of specific materials is sealed in a limitedspace and subjected to a specific elevated temperature for aspecified time. Following th
11、is exposure the dielectric break-down voltage of the insulated conductors is used as a basis forjudging the compatibility of the candidate system.5. Significance and Use5.1 This test method is useful for evaluating a combinationof materials for potential use in an electrical insulation system.6. App
12、aratus6.1 Oven, capable of maintaining the required exposuretemperature within 63 C.1This test method is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.17 on Fire and Thermal Properties.Current edition
13、 approved Nov. 1, 2016. Published November 2016. Originallyapproved in 1994. Last previous edition approved in 2009 as D5642 09. DOI:10.1520/D5642-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStand
14、ards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.2 Glass Tubes with inside volu
15、me not exceeding 900 mLthat can be sealed. Two general types are described as follows:6.2.1 Flanged High Temperature Glass Tubes which aredesigned to be sealed with metal rings and gaskets arepreferred.6.2.2 Glass Tubes, which can be fusion sealed after theaddition of all materials are acceptable al
16、ternatives.6.3 Gasket Materials for use with tubes described in 6.2.1.6.3.1 Type TFE (Tetrafluoroethylene) or FEP (Perfluoroeth-ylene Propylene) Fluorocarbon.6.3.2 Hexafluoropropylenevinylidene fluoride elastomercan be used for exposure temperatures not exceeding 155 C.6.4 Apparatus in conformance w
17、ith Test Method D149 tomeasure dielectric breakdown voltage.7. Material Specimens7.1 The specific list of materials to be tested is to beestablished by agreement between interested parties.7.2 Represent each of the non-metallic components of theelectrical insulation system, with the exception of an
18、impreg-nating varnish and insulated conductors, with a specimenhaving a minimum mass of 250 mg.7.3 Insulated Conductor Specimens:7.3.1 Use film insulated magnet wire twisted pairs con-structed in accordance with Test Methods D1676;18AWGheavy build is preferred.7.3.2 For conductors not suitable for c
19、onstructing twistedpairs, use specimens having a minimum length of 200 mm.NOTE 1An example of conductors not suitable for constructingtwisted pairs is fibrous wrapped conductors. They shall be represented asdescribed in 7.3.2.7.4 Apply impregnating varnish to the insulated conductorsand cure per man
20、ufacturers recommendations.8. Procedures8.1 Tube Loading and Sealing:8.1.1 Clean and dry tubes as needed prior to use.8.1.2 Prepare one tube with the materials that represent thereference system. Insert all materials as specified in Section 7into the tube. For each magnet wire type insert a minimum
21、offive twisted pairs or three straight lengths prepared in accor-dance with Section 7.NOTE 2It is acceptable to place a stainless steel screen as a barrier torestrict physical contact of the insulated conductors from the othermaterials in the tube, to avoid damage to the insulated conductorspecimens
22、.8.1.3 Prepare one tube for each candidate system in thesame manner in which the reference system tube was prepared.8.1.4 Condition each unsealed tube and its contents for 1 hat 105 C. The purpose of this procedure is to minimize themoisture content of all materials in the tube. It is an acceptablep
23、rocedure to condition materials outside the tube to allowsufficient drying prior to 8.1.2 and 8.1.3. Concurrently condi-tion tubes and gaskets.8.1.5 Certain materials, including but not limited to hygro-scopic papers, require additional conditioning to remove mois-ture. If agreed upon by interested
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD564220164898STANDARDTESTMETHODFORSEALEDTUBECHEMICALCOMPATIBILITYTEST 密封 管道 化学 兼容性 试验 标准 方法 PDF

链接地址:http://www.mydoc123.com/p-520327.html