ASTM D5579-2012 Standard Test Method for Evaluating the Thermal Stability of Manual Transmission Lubricants in a Cyclic Durability Test《在循环耐久性试验中手动变速箱润滑油热稳定性评定的标准试验方法》.pdf
《ASTM D5579-2012 Standard Test Method for Evaluating the Thermal Stability of Manual Transmission Lubricants in a Cyclic Durability Test《在循环耐久性试验中手动变速箱润滑油热稳定性评定的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5579-2012 Standard Test Method for Evaluating the Thermal Stability of Manual Transmission Lubricants in a Cyclic Durability Test《在循环耐久性试验中手动变速箱润滑油热稳定性评定的标准试验方法》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:D557910a Designation: D5579 12Standard Test Method forEvaluating the Thermal Stability of Manual TransmissionLubricants in a Cyclic Durability Test1This standard is issued under the fixed designation D5579; the number immediately following the designation indicates the year oforiginal ad
2、option or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the thermal stability of fluids for use in he
3、avy duty manual transmissions when operated at hightemperatures.1.2 The lubricant performance is measured by the number of shifting cycles that can be performed without failure ofsynchronization when the transmission is operated while continuously cycling between high and low range.1.3 Correlation o
4、f test results with truck transmission service has not been established. However, the procedure has been shownto appropriately separate two transmission lubricants, which have shown satisfactory and unsatisfactory field performance in thetrucks of one manufacturer.1.4 Changes in this test method may
5、 be necessary due to refinements in the procedure, obsolescence of parts, or reagents, andso forth. These changes will be incorporated by Information Letters issued by the ASTM Test Monitoring Center (TMC).2The testmethod will be revised to show the content of all the letters, as issued.1.5 The valu
6、es stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.5.1 ExceptionWhen materials, products, or equipment are available only in inch-pound units, S
7、I units are omitted.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to u
8、se.1.7 This test method is arranged as follows:SectionScope 1Referenced Documents 2Terminology 3Summary of Test Method 4Significance and Use 5Apparatus 6Test Transmission 6.2Transmission Mounts 6.3Oil-Circulating System 6.4Oil Return Hole 6.5Air Pressure Controls 6.6Drive System 6.7Instrumentation 6
9、.8Thermocouple Placement 6.9Reagents and Materials 7Safety 8Preparation of Apparatus 9Cleaning of Parts 9.1Assembly 9.2Calibration 10Transmission and Test Stand Calibration 10.1Reference Oils 10.2Reference Oil Test Frequency 10.3Instrumentation Calibration 10.4Shift Time Calibration 10.5Operating Pr
10、ocedure 111This test method is under the jurisdiction of ASTM Committee D02 on Petroleum Products and Lubricants and is the direct responsibility of Subcommittee D02.B0.03on Automotive Gear Lubricants or when shifting from low range to high range, for the countershaft speed to decrease from(1700 to
11、500) r/min.3.2.6 synchronizersynchronizer, na pack of friction and reaction plates used to match the speeds of the low- and high-rangegears prior to engagement.3.2.7 unsynchronized shiftunsynchronized shift, na shift in which the speed of the mating gears is not matched to the speedof the transmissi
12、on output shaft by the synchronizer.4. Summary of Test Method4.1 Prior to each test run, the transmission is disassembled and all parts, including the case and the oil-circulating and heatingsystems, are thoroughly cleaned. The transmission is rebuilt with a new synchronizer assembly, including meas
13、ured shifter fork,friction, and reaction disks. All other worn or defective parts are replaced.4.2 The rebuilt transmission is installed on a test stand.4.3 The transmission and oil system are flushed with the test oil in accordance with the flush procedure.4.4 The flush oil is drained, and the test
14、 oil is measured and charged to the transmission.4.5 The transmission is started and operated in low range until the oil temperature reaches the test operating range.3For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual
15、Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.4Available from Society of Automotive Engineers (SAE), 400 Commonwealth Dr., Warrendale, PA 15096-0001.5Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robb
16、ins Ave., Philadelphia, PA 19111-5098.6Available from Volvo Powertrain, North America, 13302 Pennsylvania Ave., Hagerstown, MD 21742.D5579 1224.6 The transmission is automatically cycled between low and high range until two unsynchronized shifts occur or the desiredlength of test is reached without
17、failure. The time required to shift from high range to low range is recorded each hour.4.7 At the conclusion of the test, the test parts are removed and visually inspected. The shifter fork and friction plates aremeasured again to determine wear.5. Significance and Use5.1 This test method is used to
18、 evaluate automotive manual transmission fluids for thermal instability, which results indeterioration of synchronizer performance.5.2 This test method may also be utilized in other specifications and classifications of transmission and gear lubricants such asthe following:5.2.1 (final API designati
19、on of PG-1),5.2.2 Military Specification MIL-L-2105,5.2.3 SAE Information Report J308 Axle and Manual Transmission Lubricants, and5.2.4 Mack Truck GO-H Gear Lubricant Specification.6. Apparatus6.1 Table 1 is a list of the make and model of recommended instruments and equipment.6.2 Test TransmissionT
20、he test transmission is a MACK T2180, configuration 11KBA51431 (see Fig. 1). Some parts in thetransmission are to be removed and some are to be added before testing, as listed in Table 2. The main box shift rail cover canbe replaced with an aluminum plate to facilitate transmission cleaning at end o
21、f test.6.3 Transmission MountsThe transmission is mounted as shown in Fig. 2.6.4 Oil-Circulating SystemThe system heats the oil to the specified operating temperature of 250 6 5F (121 C 6 2.7 C)and maintains this temperature throughout the duration of the test. The power density of the heater is not
22、 high enough to causedegradation of the oil (22 to 25 W/in.2(3.4 W/cm2to 3.9 W/cm2). The oil flow rate is between 6 and 10 gal/min (23 L/min to 38L/min). A layout of the oil-circulation system is shown in Fig. 3. A detailed drawing of the recommended oil heating chamber isTABLE 1 Recommended Test St
23、and ComponentsItem Manufacturer Part No.Panel MetersTailshaft rpm Newport P-6031D20DCountershaft rpm Newport P-6031D20DShift time Newport P-6031D20DCoast down time Newport P-6031D20DControl IndicationTemperature controller Omron ESEX-AFTemperature indicator Newport INF-0-0-0-0-JFCycle counter Reding
24、ton P2-1006-115ACCycle timer Omron H5BR-B-AC100-240T/C selector switch Thermo Electric 33112Oil psi gage/safety Murphy A-20EO, O-30 psiAir supply gage U.S. Gage P44U, O-160 psiAir regulator Norgren RO-8-300 RNMAShift solenoid Asco 8317G35, 3-waysolenoidMag. pickup Electro 3010AN12 VDC Power supply S
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD55792012STANDARDTESTMETHODFOREVALUATINGTHETHERMALSTABILITYOFMANUALTRANSMISSIONLUBRICANTSINACYCLICDURABILITYTEST

链接地址:http://www.mydoc123.com/p-520156.html