ASTM D5504-2008 Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence《用气相色谱和化学发光法测定天然气和气体燃料中硫化物含量的.pdf
《ASTM D5504-2008 Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence《用气相色谱和化学发光法测定天然气和气体燃料中硫化物含量的.pdf》由会员分享,可在线阅读,更多相关《ASTM D5504-2008 Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence《用气相色谱和化学发光法测定天然气和气体燃料中硫化物含量的.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5504 08Standard Test Method forDetermination of Sulfur Compounds in Natural Gas andGaseous Fuels by Gas Chromatography andChemiluminescence1This standard is issued under the fixed designation D 5504; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is primarily for the determination ofspeciated volatile s
3、ulfur-containing compounds in high meth-ane content gaseous fuels such as natural gas. It has beensuccessfully applied to other types of gaseous samples includ-ing air, digester, landfill, and refinery fuel gas. The detectionrange for sulfur compounds, reported as picograms sulfur, isten (10) to one
4、 million (1 000 000). This is equivalent to 0.01to 1 000 mg/m3, based upon the analysis ofa1ccsample.1.2 The range of this test method may be extended to higherconcentration by dilution or by selection of a smaller sampleloop.NOTE 1 Dilution will reduce method precision.1.3 This test method does not
5、 purport to identify all sulfurspecies in a sample. Only compounds that are eluted throughthe selected column under the chromatographic conditionschosen are determined. The detector response to sulfur isequimolar for all sulfur compounds within the scope (1.1)ofthis test method. Thus, unidentified c
6、ompounds are determinedwith equal precision to that of identified substances. Totalsulfur content is determined from the total of individuallyquantified components.1.4 The values stated in SI units are standard. The valuesstated in inch-pound units are for information only.1.5 This standard does not
7、 purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards
8、:2D 1072 Test Method for Total Sulfur in Fuel Gases byCombustion and Barium Chloride TitrationD 1945 Test Method for Analysis of Natural Gas by GasChromatographyD 3609 Practice for Calibration Techniques Using Perme-ation TubesD 4468 Test Method for Total Sulfur in Gaseous Fuels byHydrogenolysis and
9、 Rateometric ColorimetryE 594 Practice for Testing Flame Ionization Detectors Usedin Gas or Supercritical Fluid Chromatography3. Summary of Test Method3.1 The analysis of gaseous sulfur compounds is challeng-ing due to the reactivity of these substances. They are difficultto sample and analyze. Idea
10、lly, analysis is performed on-site toeliminate sample deterioration as a factor in analysis. Samplingmust be performed using non-reactive containers, such asSilcosteel3lined vessels, Tedlar4bags with polypropylenefittings or the equivalent. Tedlar4bag samples require protec-tion from light and heat.
11、 Laboratory equipment must be inert orpassivated to ensure reliable results.3.2 A one cc (mL) sample is injected into a gas chromato-graph where it is eluted through a megabore, thick film, methylsilicone liquid phase, open tubular partitioning column or othersuitable column, and separated into its
12、individual constituents.3.3 Sulfur Chemiluminescence DetectionAs sulfur com-pounds elute from the gas chromatographic column, they areprocessed in a flame ionization detector (FID) or a heatedcombustion zone. The products are collected and transferred toa sulfur chemiluminescence detector (SCD). Thi
13、s techniqueprovides a sensitive, selective, linear response to volatile sulfurcompounds and may be used while collecting hydrocarbon andfixed gas data from a FID.3.3.1 Detectors in Series with a SCDA SCD can fre-quently be used in series with other fixed gas and hydrocarbondetectors. However, regula
14、tory bodies may question detectorcompatibility and require demonstration of equivalence be-tween a SCD in a multi-detector system and a SCD operated1This test method is under the jurisdiction ofASTM Committee D03 on GaseousFuels and is the direct responsibility of Subcommittee D03.05 on Determinatio
15、n ofSpecial Constituents of Gaseous Fuels.Current edition approved June 15, 2008. Published July 2008. Originallyapproved in 1994. Last previous edition approved in 2006 as D 5504 01(2006).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at servic
16、eastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Silcosteel is a trademark of Restek Corporation, 110 Benner Circle Bellefonte,PA, 16823.4Tedlar is a trademark of DuPont.1Copyright ASTM International, 100 Barr Harbor Dri
17、ve, PO Box C700, West Conshohocken, PA 19428-2959, United States.using a FID or combustion zone.The user is referred to USEPAMethod 301 for an example of a general equivalence proce-dure.3.3.2 Alternative DetectorsThis test method is written forthe sulfur chemiluminescent detector but other sulfur s
18、pecificdetectors can be used provided they have sufficient sensitivity,respond to all eluted sulfur compounds, do not suffer frominterferences and satisfy quality assurance criteria. Regulatoryagencies may require demonstration of equivalency of alterna-tive detection systems to the SCD.4. Significa
19、nce and Use4.1 Many sources of natural and petroleum gases containsulfur compounds that are odorous, corrosive, and poisonous tocatalysts used in gaseous fuel processing.4.2 Low ppm amounts of sulfur odorants are added tonatural gas and LP gases for safety purposes. Some odorantsare unstable and rea
20、ct to form compounds having lower odorthresholds. Quantitative analysis of these odorized gases en-sures that odorant injection equipment is performing to speci-fication.4.3 Although not intended for application to gases otherthan natural gas and related fuels, this test method has beensuccessfully
21、applied to fuel type gases including refinery,landfill, cogeneration, and sewage digester gas. Refinery,landfill, sewage digester and other related fuel type gasesinherently contain volatile sulfur compounds that are subject tofederal, state, or local control. The methane fraction of thesefuel type
22、gases are occasionally sold to distributors of naturalgas. For these reasons, both regulatory agencies and productionand distribution facilities may require the accurate determina-tion of sulfur to satisfy regulatory, production or distributionrequirements. Fuel gases are also used in energy product
23、ion orare converted to new products using catalysts that are poisonedby excessive sulfur in the feed gas. Industry frequently requiresmeasurement of sulfur in these fuel type gases to protect theircatalyst investments.4.4 Analytical MethodsGas chromatography (GC) iscommonly used in the determination
24、 of fixed gas and organiccomposition of natural gas (Test Method D 1945). OtherstandardASTM methods for the analysis of sulfur in fuel gasesinclude Test Methods D 1072 and D 4468 for total sulfur andTest Methods D 4010 and D 4884 for hydrogen sulfide.5. Apparatus5.1 ChromatographAny gas chromatograp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD55042008STANDARDTESTMETHODFORDETERMINATIONOFSULFURCOMPOUNDSINNATURALGASANDGASEOUSFUELSBYGASCHROMATOGRAPHYANDCHEMILUMINESCENCE

链接地址:http://www.mydoc123.com/p-519981.html