ASTM D5465-1993(2012) Standard Practice for Determining Microbial Colony Counts from Waters Analyzed by Plating Methods 《由沉积法分析的水测定微生物计数的标准实施规程》.pdf
《ASTM D5465-1993(2012) Standard Practice for Determining Microbial Colony Counts from Waters Analyzed by Plating Methods 《由沉积法分析的水测定微生物计数的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5465-1993(2012) Standard Practice for Determining Microbial Colony Counts from Waters Analyzed by Plating Methods 《由沉积法分析的水测定微生物计数的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5465 93 (Reapproved 2012)Standard Practice forDetermining Microbial Colony Counts from Waters Analyzedby Plating Methods1This standard is issued under the fixed designation D5465; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These practices cover recommended procedures forcounting colonies and reporting colony-forming
3、units (CFU)on membrane filters (MF) and standard pour and spread plates.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine t
4、he applica-bility of regulatory limitations prior to use.2. Significance and Use2.1 These practices provide a uniform set of counting,calculating, and reporting procedures for ASTM test methodsin microbiology.SectionACounting Colonies on Membrane Filters 4BCounting Colonies on Pour Plates 5CCounting
5、 Colonies on Spread Plates 62.2 The counting rules provide a best attainable estimate ofmicroorganisms in the sample, since the samples cannot beheld and reanalyzed at a later date.3. Hazards3.1 The analyst/technician must know and observe thenormal good laboratory practices and safety procedures re
6、-quired in a microbiology laboratory while preparing, using, anddisposing of cultures, reagents, and materials.PRACTICE ACOUNTING COLONIES ONMEMBRANE FILTERS4. Procedure4.1 The grid lines help in counting the colonies. Count themfor the organism of interest following a preset plan such as thatshown
7、in Fig. 1. Some colonies will be in contact with the gridlines. A suggested procedure for reducing error in counting isshown in Fig. 2. Count the colonies in the squares indicated bythe arrows.4.2 The fluorescent lamp tube should be nearly parallel withand directly over the membrane filter. Ideally,
8、 the lamp isattached to and surrounds the objective nosepiece of thestereoscopic microscope. Count the colonies individually, evenif they are in contact with each other. The technician must learnto recognize the difference between two or more colonies thathave grown into contact with each other and
9、the single,irregularly shaped colonies that sometimes develop on mem-brane filters. The latter colonies are usually associated with afiber or particulate material and conform to the shape and sizeof the fiber or particulates. Colonies that have grown togetheralmost invariably show a very fine line o
10、f contact.4.3 Count the colonies with a stereoscopic (dissecting)microscope that provides a magnification of at least 10 to 153.4.4 See Table 1 for guidance on acceptable counting limits.4.5 Calculation of ResultsSelect the membrane with thenumber of CFU in the acceptable range and calculate thecoun
11、t/reporting volume according to the following generalformula:1These practices are under the jurisdiction of ASTM Committee D19 on Waterand are the direct responsibility of Subcommittee D19.24 on Water Microbiology.Current edition approved June 1, 2012. Published August 2012. Originallyapproved in 19
12、93. Last previous edition approved in 2004 as D6465 93 (2004).DOI: 10.1520/D5465-93R12.FIG. 1 Colony Counting Pathway (The Inner Circle Indicates theEffective Filtering Area; the Dashed Line Indicates the Pathway)1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, P
13、A 19428-2959, United States.CFU/mL 5colonies countedvolume of sample filtered in mL3 1 (1)CFU/100 mL 5colonies countedvolume of sample filtered in mL3 100 (2)4.6 Counts Within the Acceptable Limits:4.6.1 The acceptable range of counts on a membrane forsamples that are diluted is a function of the or
14、ganism/testcombination as given in Table 1.4.6.2 Assume that the filtration of volumes of 80, 20, 5, and1 mL produced counts of 250, 60, 15, and 4, respectively. Donot count the colonies on all filters. Select the MF(s) within theacceptable counting range and then limit the actual counting tosuch me
15、mbranes. After selecting the best MF for counting, inthis case that with a 60-CFU count, the analyst counts CFUaccording to the procedures shown in Fig. 1 and Fig. 2 andapplies the general formula as follows:60203 1 or 3 100! 5 3 or 300! (3)Report as 3 CFU/mL or 300 CFU/100 mL.4.6.3 If there are acc
16、eptable counts on replicate plates, carrythe counts independently to final reporting units, and thencalculate the arithmetic mean of these counts to obtain the finalreported value. For example, 1 mLvolumes produced counts of26 and 36 CFU/mL or counts of 2600 and 3600 CFU/100 mL:26 1 3625 31 (4)Repor
17、t as 31 CFU/mL.2600 1 360025 3100 (5)Report as 3100 CFU/100 mL.4.6.4 If more than one dilution produced acceptable counts,count the colonies for each dilution, carry the counts indepen-dently to final reporting units, and then average for the finalreported value. For example, assume that volumes of
18、0.3, 0.1,0.03, and 0.01 mL produced colony counts of too numerous tocount (TNTC), 75, 30, and 8, respectively. In this example, twovolumes, 0.1 and 0.03, produce colonies in an acceptablecounting range. Carry each MF count independently to acount/mL or count/100 mL:750.13 1 or 3 100! 5 750 CFU/mL or
19、 75 000 CFU/100 mL!(6)300.033 1 or 3 100!= 1 000 CFU/mL (or100 000 CFU/100 mL)Then calculate the arithmetic mean of these counts to obtainthe final reported value:750 1 1 00025 875 (7)Report as 880 CFU/mL.75 000 1 100 00025 87 500 (8)Report as 88 000 CFU/100 mL.4.6.5 For finished drinking water samp
20、les only, countablemembranes may contain from one colony to the upper limit ofthe test (see Table 1). Count the target colonies/volume filtered.Calculate and report the number of CFU/100 mL.4.7 Counts Outside Acceptable Limits:4.7.1 Zero counts recorded as 800 000 CFU/100 mL.4.7.6.1 Alternatively, s
21、mall sample volumes or sample di-lutions can be used to minimize the TNTC problem. Replicatesof smaller sample volumes or sample dilutions may be filteredand the results combined. If the MF technique is not applicable,the most probable number (MPN) is useful.4.7.7 If there is no result because of co
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD546519932012STANDARDPRACTICEFORDETERMININGMICROBIALCOLONYCOUNTSFROMWATERSANALYZEDBYPLATINGMETHODS

链接地址:http://www.mydoc123.com/p-519885.html