1、Designation: D5463 13Standard Guide forUse of Test Kits to Measure Inorganic Constituents inWater1This standard is issued under the fixed designation D5463; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This guide covers general considerations for the use oftest kits for quantitative determination of analytes in water andwastewater.
3、 Test kits are available from various manufacturersfor the determination of a wide variety of analytes in drinkingwater, surface or ground waters, domestic and industrialfeedwaters and wastes, and water used in power generation andsteam raising. See Table 1 for a listing of some of the types ofkits
4、that are available for various inorganic analytes in water.21.2 Ranges, detection limits, sensitivity, accuracy, and sus-ceptibility to interferences vary from kit to kit, depending onthe methodology selected by the manufacturer. In some cases,kits are designed to replicate exactly an official test
5、method ofa standard-setting organization such as the Association ofOfficial Analytical Chemists (AOAC), American Public HealthAssociation (APHA), ASTM, or the U.S. Environmental Pro-tection Agency (USEPA). In other cases, minor modificationsof official test methods are made for various reasons, such
6、 as toimprove performance, operator convenience, or ease of use.Adjustments may be made to sample size, reagent volumes andconcentrations, timing, and details of the analytical finish. Inyet other cases, major changes may be made to the official testmethod, such as the omission of analytical steps,
7、change of theanalytical finish, omission of reagents, or substitution of onereagent for another. Reagents in test kits are often combined toobtain a fewer number and make the test easier to use.Additives may also be used to minimize interferences and tomake the reagent more stable with time. A kit t
8、est method maybe based on a completely different technology, not approved byany official or standard-setting organization. Combinations oftest kitsmulti-parameter test kitsmay be packaged tosatisfy the requirements of a particular application conve-niently. The test kits in such combination products
9、 may be usedto make dozens of determinations of several parameters.1.3 Test kit reagent refills are commonly available frommanufacturers. Refills permit cost savings through reuse of themajor test kit components.1.4 Because of the wide differences among kits and meth-odologies for different analytes
10、, universal instructions cannotbe provided. Instead, the user should follow the instructionsprovided by the manufacturer of a particular kit.1.5 A test kit or kit component should not be used after themanufacturers expiration date; it is the users responsibility todetermine that the performance is s
11、atisfactory.1.6 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to es
12、tablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 10.2. Referenced Documents2.1 ASTM Standards:3D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD3370 Prac
13、tices for Sampling Water from Closed ConduitsD4453 Practice for Handling of High Purity Water SamplesD4691 Practice for Measuring Elements in Water by FlameAtomic Absorption SpectrophotometryD5810 Guide for Spiking into Aqueous SamplesD5847 Practice for Writing Quality Control Specificationsfor Stan
14、dard Test Methods for Water AnalysisE178 Practice for Dealing With Outlying ObservationsE275 Practice for Describing and Measuring Performance ofUltraviolet and Visible SpectrophotometersE958 Practice for Estimation of the Spectral Bandwidth ofUltraviolet-Visible Spectrophotometers1This guide is und
15、er the jurisdiction of ASTM Committee D19 on Water and isthe direct responsibility of Subcommittee D19.05 on Inorganic Constituents inWater.Current edition approved Jan. 1, 2013. Published February 2013. Originallyapproved in 1993. Last previous edition approved in 2008 as D5463 08. DOI:10.1520/D546
16、3-13.2Test kits for determining inorganic analytes in water are available from variousUnited States and foreign manufacturers, as well as from laboratory supplycompanies.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annu
17、al Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13. Terminolo
18、gy3.1 DefinitionsFor definitions of terms used in this guide,refer to Terminology D1129 and Practice D4691.3.2 Definitions of Terms Specific to This Standard:3.2.1 analyte, nthe chemical or constituent being deter-mined.3.2.2 carryover, nthe contamination of a subsequentsample by a previous sample,
19、typically due to incompletecleaning of a reused test kit component.3.2.3 expiration date, na date applied by the manufacturerafter which an accurate result is not ensured by the manufac-turer.3.2.4 finish (usually analytical finish), nthe analyticalmethodology used for the measuring step of the anal
20、ysis.3.2.5 kit (or test kit), na commercially-packaged collec-tion of components intended to simplify the analytical-testingfunction.3.2.6 interference, na matrix components effect thatmight cause an analytical bias or that might prevent a success-ful analysis.3.2.7 material safety data sheet, na fe
21、derally-mandated,safety-related document that must be made available to kit-chemistry users.3.2.8 matrix, nsample contents other than the target ana-lyte.3.2.9 offcial method, nan analytical test method officiallyapproved by an industry consensus organization (such asASTM, AOAC, or APHA) or by a gov
22、ernment entity such asthe USEPA.43.2.10 refill, na replacement package of test kit compo-nents used in testing.3.2.11 spike, na small-volume, high relative concentrationaliquot of analyte added quantitatively to a split sample as aquality check.3.2.12 split sample, na sample that is split into sub-s
23、amples that are intended to have the same composition as theoriginal sample.4. Summary of Guide4.1 Analytical test kits simplify the operational proceduresnecessary to perform an analysis. This guide includes generalconsiderations relating to the procedures to be followed inorder to ensure an accura
24、te determination. This guide alsodescribes, in general terms, the characteristics of some kit typesand kit components and includes some comments on theircapabilities, benefits and, where appropriate, their limitations.5. Significance and Use5.1 Inorganic constituents in water and wastewater must bei
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD54632013STANDARDGUIDEFORUSEOFTESTKITSTOMEASUREINORGANICCONSTITUENTSINWATER 水中 无机 成分 测量 试验 使用 标准

链接地址:http://www.mydoc123.com/p-519879.html