ASTM D5463-2003 Standard Guide for Use of Test Kits to Measure Inorganic Constituents in Water《水中无机成分测量用整套试验工具使用的标准指南》.pdf
《ASTM D5463-2003 Standard Guide for Use of Test Kits to Measure Inorganic Constituents in Water《水中无机成分测量用整套试验工具使用的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5463-2003 Standard Guide for Use of Test Kits to Measure Inorganic Constituents in Water《水中无机成分测量用整套试验工具使用的标准指南》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5463 03Standard Guide forUse of Test Kits to Measure Inorganic Constituents inWater1This standard is issued under the fixed designation D 5463; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This guide covers general considerations for the use oftest kits for quantitative determination of analytes in water andwastewat
3、er. Test kits are available from various manufacturersfor the determination of a wide variety of analytes in drinkingwater, surface or ground waters, domestic and industrialfeedwaters and wastes, and water used in power generation andsteam raising. See Table 1 for a listing of some of the types ofki
4、ts that are available for various inorganic analytes in water.21.2 Ranges, detection limits, sensitivity, accuracy, and sus-ceptibility to interferences vary from kit to kit, depending onthe methodology selected by the manufacturer. In some cases,kits are designed to replicate exactly an official te
5、st method ofa standard-setting organization such as the Association ofOfficial Analytical Chemists (AOAC), American Public HealthAssociation (APHA), ASTM, or the U.S. Environmental Pro-tection Agency (USEPA). In other cases, minor modificationsof official test methods are made for various reasons, s
6、uch as toimprove performance, operator convenience, or ease of use.Adjustments may be made to sample size, reagent volumes andconcentrations, timing, and details of the analytical finish. Inyet other cases, major changes may be made to the official testmethod, such as the omission of analytical step
7、s, change of theanalytical finish, omission of reagents, or substitution of onereagent for another. Reagents in test kits are often combined toobtain a fewer number and make the test easier to use.Additives may also be used to minimize interferences and tomake the reagent more stable with time. A ki
8、t test method maybe based on a completely different technology, not approved byany official or standard-setting organization. Combinations oftest kitsmulti-parameter test kitsmay be packaged tosatisfy the requirements of a particular application conve-niently. The test kits in such combination produ
9、cts may be usedto make dozens of determinations of several parameters.1.3 Test kit reagent refills are commonly available frommanufacturers. Refills permit cost savings through reuse of themajor test kit components.1.4 Because of the wide differences among kits and meth-odologies for different analy
10、tes, universal instructions cannotbe provided. Instead, the user should follow the instructionsprovided by the manufacturer of a particular kit.1.5 A test kit or kit component should not be used after themanufacturers expiration date; it is the users responsibility todetermine that the performance i
11、s satisfactory.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.
12、 For specificprecautionary statements, see Section 10.2. Referenced Documents2.1 ASTM Standards:D 1129 Terminology Relating to Water3D 1192 Guide for Equipment for Sampling Water andSteam in Closed Conduits3D 1193 Specification for Reagent Water3D 3370 Practices for Sampling Water from Closed Con-du
13、its3D 4453 Practice for Handling of Ultra-Pure Water Samples3D 4691 Practice for Measuring Elements in Water by FlameAtomic Absorption Spectrophotometry3D 5810 Guide for Spiking into Aqueous Samples3D 5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water Analysi
14、s4E 178 Practice for Dealing with Outlying Observations5E 275 Practice for Describing and Measuring Performanceof Ultraviolet, Visible, and Near Infrared Spectrophotom-eters6E 958 Practice for Measuring Practical Spectral Bandwidthof Ultraviolet-Visible Spectrophotometers61This guide is under the ju
15、risdiction of ASTM Committee D19 on Water and isthe direct responsibility of Subcommittee D19.05 on Inorganic Constituents inWater.Current edition approved June 10, 2003. Published July 2003. Originallyapproved in 1993. Last previous edition approved in 1998 as D 546398.2Test kits for determining in
16、organic analytes in water are available from variousUnited States and foreign manufacturers, as well as from laboratory supplycompanies.3Annual Book of ASTM Standards, Vol 11.01.4Annual Book of ASTM Standards, Vol 11.02.5Annual Book of ASTM Standards, Vol 14.02.6Annual Book of ASTM Standards, Vol 03
17、.06.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3. Terminology3.1 DefinitionsFor definitions of terms used in this guide,refer to Terminology D 1129 and Practice D
18、 4691.3.2 Definitions of Terms Specific to This Standard:3.2.1 analytethe chemical or constituent being deter-mined.3.2.2 carryoverthe contamination of a subsequent sampleby a previous sample, typically due to incomplete cleaning ofa reused test kit component.3.2.3 expiration datea date applied by t
19、he manufacturerafter which an accurate result is not ensured by the manufac-turer.3.2.4 finish (usually analytical finish)the analytical meth-odology used for the measuring step of the analysis.3.2.5 kit (or test kit)a commercially packaged collectionof components that is intended to simplify the an
20、alytical testingfunction.3.2.6 interferencean effect of a matrix component thatmight cause an analytical bias or that might prevent a success-ful analysis.3.2.7 material safety data sheeta federally-mandated,safety-related document that must be made available to kitchemistry users.3.2.8 matrixsample
21、 contents other than the target analyte.3.2.9 offcial methodan analytical test method officiallyapproved by an industry consensus organization such asASTM,AOAC, orAPHAor by a government entity such as theUSEPA.73.2.10 refilla replacement package of test kit componentsused in testing.3.2.11 spikea sm
22、all volume, high relative concentrationaliquot of analyte added quantitatively to a split sample as aquality check.3.2.12 split samplea sample that is split into sub-samplesthat are intended to have the same composition as the originalsample.4. Summary of Guide4.1 Analytical test kits simplify the o
23、perational proceduresnecessary to perform an analysis. This guide includes generalconsiderations relating to the procedures to be followed inorder to ensure an accurate determination. This guide alsodescribes, in general terms, the characteristics of some kit typesand kit components and includes som
24、e comments on theircapabilities, benefits and, where appropriate, their limitations.5. Significance and Use5.1 Inorganic constituents in water and wastewater must beidentified and measured to support effective water qualitymonitoring and control programs. Currently, one of the sim-plest, most practi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD54632003STANDARDGUIDEFORUSEOFTESTKITSTOMEASUREINORGANICCONSTITUENTSINWATER 水中 无机 成分 测量 整套 试验 工具

链接地址:http://www.mydoc123.com/p-519877.html