ASTM D5459-1995(2007) Standard Test Method for Machine Direction Elastic Recovery and Permanent Deformation and Stress Retention of Stretch Wrap Film《张拉材料加工方向弹性恢复和永久变形和应力保持标准试验方法》.pdf
《ASTM D5459-1995(2007) Standard Test Method for Machine Direction Elastic Recovery and Permanent Deformation and Stress Retention of Stretch Wrap Film《张拉材料加工方向弹性恢复和永久变形和应力保持标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5459-1995(2007) Standard Test Method for Machine Direction Elastic Recovery and Permanent Deformation and Stress Retention of Stretch Wrap Film《张拉材料加工方向弹性恢复和永久变形和应力保持标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5459 95 (Reapproved 2007)Standard Test Method forMachine Direction Elastic Recovery and PermanentDeformation and Stress Retention of Stretch Wrap Film1This standard is issued under the fixed designation D 5459; the number immediately following the designation indicates the year oforig
2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of recoveryfrom extens
3、ion, permanent deformation, and stress retention ofstretch wrap film.1.2 Several levels of extension are included to ascertain theeffect of both small and large extensions.1.3 The values stated in inch-pound units are to be regardedas the standard. The SI units given in parentheses are forinformatio
4、n only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Refer
5、enced Documents2.1 ASTM Standards:2D 882 Test Method for Tensile Properties of Thin PlasticSheetingD 1898 Practice for Sampling of Plastics3D 996 Terminology of Packaging and Distribution Environ-mentsD 2103 Specification for Polyethylene Film and SheetingE 122 Practice for Calculating Sample Size t
6、o Estimate,With a Specified Tolerable Error, the Average for aCharacteristic of a Lot or ProcessE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 Definitions: General definitions for packaging and dis-tribution environments are found i
7、n Terminology D 996.3.2 Definitions of Terms Specific to This Standard:3.2.1 elastic recoverythe percentage of a given deforma-tion that behaves elastically, after 180 s when subjected to theextensions prescribed in this test method.3.2.2 permanent deformationthe increase in length, ex-pressed as a
8、percentage of the original length, by which anelastic material fails to return to original length after subjectedto the extensions prescribed in the test procedure in thismethod.3.2.3 stress retentionthe percentage of stress retained 60 sor 24 h, or both, after application.4. Summary of Test Method4
9、.1 Elastic properties of the films are determined by sub-jecting specimens to known extensions and by measuring thequantity of recovery and the permanent change with respect tothe original dimensions.5. Significance and Use5.1 Elastic recovery is related to the ability of a package toresume its orig
10、inal shape after being distended during its usecycle.5.2 Elastic recovery also relates to the tightness or snugnessof a package.5.3 Stress retention is related to the tightness or snugness ofa package.6. Apparatus6.1 Tensile Testing Machine, with a reversible chart, com-plying with the requirements
11、listed for Method A of TestMethods D 882 with grips satisfactory for the purpose. Refer tosection on grips in Test Methods D 882.6.2 Specimen Cutter, capable of producing nick-free 1 60.001 in. (25.4 6 0.03 mm) testing strips, with a precision of1 6 0.001 in. (25.4 6 0.03 mm).46.3 Micrometer, capabl
12、e of measuring the thickness ofspecimens to 0.001 in. (0.03 mm) as described in 8.9.1.1 ofSpecification D 2103.1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.25 on Palletizingand Unitizing of Loads.Current edition ap
13、proved April 1, 2007. Published May 2007. Originallyapproved in 1994. Last previous edition approved in 2001 as D 5459 95 (2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informati
14、on, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4A JDC-1-10 precision cutter is available from Thwing-Albert Instrument Co.,10960 Dutton Rd. Philadelphia, PA 19154, or similar manufacturers.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoh
15、ocken, PA 19428-2959, United States.7. Sampling7.1 Acceptance SamplingSampling shall be in accordancewith Practice D 1898.7.2 Sampling for Other PurposesThe sampling and thenumber of test specimens depend on the purposes of thetesting. Practice E 122 is recommended. Test specimens aretaken from seve
16、ral rolls of film, and when possible, fromseveral production runs of a product. Strong conclusions abouta specific property of a film cannot be based on a single roll ofproduct.8. Specimen Preparation8.1 Cut five strips parallel to the machine direction that are1.0 in. (25.4 mm) wide and long enough
17、 to provide for aninitial grip separation of 5 in. (127 mm).8.2 Measure the thickness of each specimen at five equallyspaced points in the area that will be between the grips to thenearest 0.001 in. (0.003 mm) and record the values.9. Preparation of Apparatus9.1 Select a load range so that the scans
18、 cover approxi-mately two-thirds of the chart width.9.2 Calibrate the strain gage as directed by the manufacturerof the machine. Set the rate of grip separation at 5 in./min (127mm/min) and the initial grip separation at 5 in. (127 mm).10. Conditioning10.1 Sample ConditioningCondition the test speci
19、mens atthe standard atmospheric condition for not less than 24 h priorto testing, as described in Practice E 691.10.2 Test ConditionsTesting shall be conducted under thecondition specified for specimen conditioning in 10.1.11. Procedure11.1 Clamp the first specimen in the grips so that it is freeto
20、slack but is not under tension.11.2 Start the testing machine and chart, and elongate thespecimen at 5 in./min (127 mm/min) to an extension of 15, 50,100, 150 or 200 % and stop the testing machine and chart. (InFig. 1, at extension AE, curve AB is generated.)11.3 Wait 60 s or 24 h, during which time
21、 the specimen willrelax. See Note 1. (In Fig. 1, extension BG is generated.)NOTE 1Slack in the specimen and misalignment of the grips are themajor causes of non-linearity of the early part of the load-extensioncurves.11.3.1 When testing materials of unknown response, inves-tigate a series of times f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD545919952007STANDARDTESTMETHODFORMACHINEDIRECTIONELASTICRECOVERYANDPERMANENTDEFORMATIONANDSTRESSRETENTIONOFSTRETCHWRAPFILM

链接地址:http://www.mydoc123.com/p-519866.html