ASTM D5403-1993(2007) Standard Test Methods for Volatile Content of Radiation Curable Materials《辐射固化材料中挥发物含量的测试方法》.pdf
《ASTM D5403-1993(2007) Standard Test Methods for Volatile Content of Radiation Curable Materials《辐射固化材料中挥发物含量的测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5403-1993(2007) Standard Test Methods for Volatile Content of Radiation Curable Materials《辐射固化材料中挥发物含量的测试方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5403 93 (Reapproved 2007)Standard Test Methods forVolatile Content of Radiation Curable Materials1This standard is issued under the fixed designation D 5403; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover procedures for the determina-tion of weight percent volatile content of coatings, inks, an
3、dadhesives designed to be cured by exposure to ultraviolet lightor to a beam of accelerated electrons.1.2 Test Method A is applicable to radiation curable mate-rials that are essentially 100 % reactive but may contain traces(no more than 3 %) of volatile materials as impurities orintroduced by the i
4、nclusion of various additives.1.3 Test Method B is applicable to all radiation curablematerials but must be used for materials that contain volatilesolvents intentionally introduced to control application viscos-ity and which are intended to be removed from the materialprior to cure.1.4 These test m
5、ethods may not be applicable to radiationcurable materials wherein the volatile material is water, andother procedures may be substituted by mutual consent of theproducer and user.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstand
6、ard.1.6 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. A specific
7、 hazardstatement is given in 15.7.2. Referenced Documents2.1 ASTM Standards:2D 2369 Test Method for Volatile Content of CoatingsE 145 Specification for Gravity-Convection and Forced-Ventilation OvensE 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 691 Practice for Conducti
8、ng an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 Definitions:3.1.1 cure, nthe condition of a coating after conversion tothe final state of cure as measured by tests generally related toend use performance and mutually agreeable to supplier andpurchaser.3.1.2 ul
9、traviolet (UV) curing, nconversion of a coatingfrom its application state to its final use state by means of amechanism initiated by ultraviolet radiation generated byequipment designed for that purpose.3.1.3 electron beam (EB) curing, nconversion of a coat-ing from its application state to its fina
10、l use state by means ofa mechanism initiated by electron beam radiation generated byequipment designed for that purpose.3.1.4 processing volatiles, nloss in specimen weight un-der test conditions that are designed to simulate actual indus-trial cure processing conditions.3.1.5 potential volatiles, n
11、loss in specimen weight uponheating at 110C for 60 min after radiation curing.3.1.5.1 DiscussionThis value is an estimation of volatileloss that may occur during aging or under extreme storageconditions. Potential volatiles may also be referred to asresidual volatiles.3.1.6 total volatiles, nsum of
12、the processing volatiles andthe potential volatiles.4. Summary of Test Methods4.1 A designated quantity of material is weighed before andafter a cure step that simulates normal industrial processing.The test specimen is weighed again after heating at 110 6 5Cfor 60 min. The percent volatile is calcu
13、lated from the losses inweight.5. Significance and Use5.1 These test methods are the procedures of choice fordetermining volatile content of materials designed to be curedby exposure to ultraviolet light or electron beam irradiation.These types of materials contain liquid reactants that react tobeco
14、me part of the film during cure, but, which under the test1These test methods are under the jurisdiction of ASTM Committee D01 onPaint and Related Coatings, Materials, and Applications and are the directresponsibility of Subcommittee D01.55 on Factory Applied Coatings on PreformedProducts.Current ed
15、ition approved June 1, 2007. Published July 2007. Originally approvedin 1993. Last previous edition approved in 2002 as D 5403 - 93 (2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
16、 information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.conditions of Test Method D 2369, will be erroneously mea-sured as volatiles. The conditions of these test
17、methods aresimilar to Test Method D 2369 with the inclusion of a step tocure the material prior to weight loss determination. Volatilecontent is determined as two separate componentsprocessingvolatiles and potential volatiles. Processing volatiles is ameasure of volatile loss during the actual cure
18、process.Potential volatiles is a measure of volatile loss that might occurduring aging or under extreme storage conditions. Thesevolatile content measurements are useful to the producer anduser of a material and to environmental interests for determin-ing emissions.6. Interferences6.1 The degree to
19、which the results of these proceduresaccurately measure the volatiles emitted during actual use isabsolutely dependent upon proper cure during the test proce-dure. Although overcure will have little or no effect uponmeasured volatiles, undercure may lead to erroneously highvalues. Since various piec
20、es of cure equipment may varywidely in efficiency, it is essential that dialogue betweenmaterial manufacturer and testing laboratory establish a cureschedule appropriate both to the material to be tested and to thecure equipment to be used in the procedure.TEST METHOD A7. Scope7.1 This test method i
21、s applicable to radiation curablematerials with solvent content less than or equal to 3 %.8. Apparatus8.1 Aluminum Substrate, standard test panels (102 mm by305 mm) or heavy gage (0.05 mm minimum) foil. Test panelsare most convenient and may be cut into smaller pieces for easeof weighing. Preconditi
22、on the substrate for 30 min at 110 65C and store in a desiccator prior to use.8.2 Forced Draft Oven, Type IIA or Type IIB as specified inSpecification E 145.8.3 Ultraviolet Light or Electron Beam CuringEquipmentThere are several commercial suppliers of labo-ratory scale equipment that simulates indu
23、strial curing pro-cesses.39. Procedure9.1 Mix the sample, if necessary, to ensure uniformity. Handstirring is recommended to avoid the entrapment of air bubbles.9.2 Weigh the preconditioned aluminum substrate, (8.1)to0.1 mg (A). The size of the aluminum substrate must allow aminimum of 0.2 g of mate
24、rial to be applied at the suppliersrecommended film thickness. Use rubber gloves or tongs, orboth, to handle samples.9.3 Apply a minimum of 0.2 g of test specimen to thealuminum substrate and reweigh to 0.1 mg (B). Prepare a totalof three test specimens.NOTE 1The elapsed time between application and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD540319932007STANDARDTESTMETHODSFORVOLATILECONTENTOFRADIATIONCURABLEMATERIALS 辐射 固化 材料 挥发物 含量 测试

链接地址:http://www.mydoc123.com/p-519693.html