ASTM D5367-2008 Standard Practice for Evaluating Coatings Applied Over Surfaces Treated With Inhibitors Used to Prevent Flash Rusting of Steel When Water or Water Abrasive Blasted《.pdf
《ASTM D5367-2008 Standard Practice for Evaluating Coatings Applied Over Surfaces Treated With Inhibitors Used to Prevent Flash Rusting of Steel When Water or Water Abrasive Blasted《.pdf》由会员分享,可在线阅读,更多相关《ASTM D5367-2008 Standard Practice for Evaluating Coatings Applied Over Surfaces Treated With Inhibitors Used to Prevent Flash Rusting of Steel When Water or Water Abrasive Blasted《.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5367 08Standard Practice forEvaluating Coatings Applied Over Surfaces Treated WithInhibitors Used to Prevent Flash Rusting of Steel WhenWater or Water/Abrasive Blasted1This standard is issued under the fixed designation D 5367; the number immediately following the designation indicate
2、s the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers procedures to evaluate t
3、he compat-ibility of coatings with inhibitors used to prevent flash rustingof steel before application of coatings.1.2 The inhibitors are used with water-blast cleaning surfacepreparation and may be used with or without abrasives.1.3 The manufacturer of the coatings shall be consulted toensure compa
4、tibility of inhibitors with the coatings.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory
5、 limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A 36/A 36M Specification for Carbon Structural SteelB117 Practice for Operating Salt Spray (Fog) ApparatusD 714 Test Method for Evaluating Degree of Blistering ofPaintsD 822 Practice for Filtered Open-Flame Carbon-Arc Expo-sures of
6、 Paint and Related CoatingsD 1193 Specification for Reagent WaterD 1654 Test Method for Evaluation of Painted or CoatedSpecimens Subjected to Corrosive EnvironmentsD 2247 Practice for Testing Water Resistance of Coatings in100 % Relative HumidityD 3359 Test Methods for Measuring Adhesion by Tape Tes
7、tD 4417 Test Methods for Field Measurement of SurfaceProfile of Blast Cleaned SteelD 4541 Test Method for Pull-Off Strength of CoatingsUsing Portable Adhesion Testers2.2 Other Standards:SSPC-SP 5 Surface Preparation Specification No. 5, WhiteMetal Blast Cleaning3SSPC-SP12/NACE No. 5 Surface Preparat
8、ion and Cleaningof Steel and Other Hard Materials by High and Ultrahigh-Pressure Water Jetting Prior to Recoating3SSPC-TR2/NACE 6C 198 Wet Abrasive Blast Cleaning3NACE TM-01-74 Laboratory Method for Evaluation ofProtective Coatings Used as Lining Materials in Immer-sion Surfaces43. Significance and
9、Use3.1 Water-blast cleaning with, (SSPC-TR2/NACE 6C 198)or without, (SSPC-SP 12/NACE No. 5) abrasive, results inflash rusting under some environmental conditions. Inhibitorsare used to prevent flash rusting while drying and beforecoating application. The inhibitor or reaction products of theinhibito
10、r on the substrate becomes part of the coating systems.Coating performance may be influenced by the inhibitor.Soluble contaminants or unreacted inhibitors left on the surfaceunder the coating may cause premature failure. This practiceincludes a comparison of coating performance with and with-out inh
11、ibitors using various laboratory tests to simulate a rangeof conditions such as high moisture, marine atmospheric orwater immersion.3.2 The user or specifier must determine the specific testmethods to be used and exposure conditions. Some testmethods referenced may not be applicable to all types ofc
12、oatings.4. Specimen Preparation4.1 Carbon steel samples of an appropriate size, in accor-dance with Specification A 36/A 36M for the specified testmethod shall be white metal blast-cleaned in accordance withSSPC-SP 5 and measure profile in accordance with TestMethods D 4417. Select an abrasive that
13、is suitable for use with1This practice is under the jurisdiction of ASTM Committee D33 on ProtectiveCoating and Lining Work for Power Generation Facilities and is the directresponsibility of Subcommittee D33.05 on Application and Surface Preparation.Current edition approved Jan. 1, 2008. Published J
14、anuary 2008. Originallyapproved in 1994. Last previous edition approved in 2000 as D 5367 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document
15、Summary page onthe ASTM website.3Available from Society for Protective Coatings (SSPC), 40 24th St., 6th Floor,Pittsburgh, PA 15222-4656, http:/www.sspc.org.4Available from National Association of Corrosion Engineers (NACE), 1440South Creek Dr., Houston, TX 77084-4906, http:/www.nace.org.1Copyright
16、ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.water-blast applications. Control panels shall be coated withthe same coating system and dry film thickness as the inhibitor-treated panels with the topcoat time as follows:Number of Panels for Ea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD53672008STANDARDPRACTICEFOREVALUATINGCOATINGSAPPLIEDOVERSURFACESTREATEDWITHINHIBITORSUSEDTOPREVENTFLASHRUSTINGOFSTEELWHENWATERORWATERABRASIVEBLASTEDPDF

链接地址:http://www.mydoc123.com/p-519601.html