ASTM D5357-2003 Standard Test Method for Determination of Relative Crystallinity of Zeolite Sodium A by X-Ray Diffraction《用X射线衍射法测定沸石钠A的相对结晶度用标准试验方法》.pdf
《ASTM D5357-2003 Standard Test Method for Determination of Relative Crystallinity of Zeolite Sodium A by X-Ray Diffraction《用X射线衍射法测定沸石钠A的相对结晶度用标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5357-2003 Standard Test Method for Determination of Relative Crystallinity of Zeolite Sodium A by X-Ray Diffraction《用X射线衍射法测定沸石钠A的相对结晶度用标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5357 03Standard Test Method forDetermination of Relative Crystallinity of Zeolite Sodium Aby X-ray Diffraction1This standard is issued under the fixed designation D 5357; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure for determining therelative crystallinity of zeolite sodium A (zeo
3、lite NaA) usingselected peaks from the X-ray diffraction pattern of the zeolite.1.2 The term “intensity of an X-ray powder diffraction(XRD) peak” refers to the “integral intensity,” either the area orcounts under the peak or the product of the peak height and thepeak width at half height.1.3 This te
4、st method provides a number that is the ratio ofintensity of portions of the XRD pattern of the sample tointensity of the corresponding portion of the pattern of areference zeolite NaA. The intensity ratio, expressed as apercentage, is then labeled relative crystallinity of NaA.1.4 This standard doe
5、s not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Stan
6、dards:D 3906 Test Method for Determination of Relative X-rayDiffraction Intensities of Faujasite-Type Zeolite-Containing Materials2E 177 Practice for Use of the Terms Precision and Bias inASTM Test Methods3E 456 Terminology Relating to Quality and Statistics3E 691 Practice for Conducting an Interlab
7、oratory Study toDetermine the Precision of a Test Method33. Summary of Test Method3.1 The XRD patterns of the zeolite NaA or zeolite NaA-containing sample and the reference sample (NaA) are ob-tained under the same conditions. A comparison of the sums ofintensities of six strong peaks in the 1132 2u
8、 range is made,giving relative crystallinity of NaA. This type of comparison iscommonly used in zeolite technology and is often referred to as“% crystallinity.”4. Significance and Use4.1 Zeolite NaA has been used as an active component inmolecular sieves employed as desiccants for natural gas,proces
9、s gas streams, sealed insulated windows, and as a builder(water softener) in household laundry detergents.4.2 This X-ray procedure is designed to allow a reporting ofthe relative degree of crystallization of NaA in the manufactureof NaA. The relative crystallinity number has proven useful intechnolo
10、gy, research, and specifications.4.3 Drastic changes in intensity of individual peaks in theXRD pattern of NaA can result from changes in distribution ofelectron density within the unit cell of the NaA zeolite. Theelectron density distribution is dependent upon the extent offilling of pores in the z
11、eolite with guest molecules, and on thenature of the guest molecules. In this XRD method, the guestmolecule H2O completely fills the pores. Intensity changesmay also result if some or all of the sodium cations in NaA areexchanged by other cations.4.4 Drastic changes in overall intensity can result f
12、romchanges in X-ray absorption attributed to non-crystallinephases, if present, in a NaA sample. If non-zeolite crystallinephases are present, their diffraction peaks may overlap withsome of the NaA diffraction peaks selected for this test method.If there is reason to suspect the presence of such co
13、mponents,then NaA peaks free of interference should be chosen foranalysis.5. Apparatus5.1 Xray Diffractometer, equipped with computerized dataacquisition and reduction capability or with a strip chartrecorder, and using copper K-alpha radiation.5.2 Drying Oven, set at 100C.5.3 Hydrator (Laboratory D
14、esiccator), maintained at about58 % relative humidity by a saturated solution of sodiumbromide, NaBr.1This test method is under the jurisdiction of ASTM Committee D32 onCatalysts and is the direct responsibility of Subcommittee D32.05 on Zeolites.Current edition approved March 10, 2003. Published Ap
15、ril 2003. Originallyapproved in 1993. Last previous edition approved in 1998 as D 5357-98.2Annual Book of ASTM Standards, Vol 05.05.3Annual Book of ASTM Standards, Vol 14.02.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.4 Planime
16、ter or Appropriate Peak Profile Analysis orDigital Integration Software, if diffractometer is not equippedwith appropriate software data analysis capability.6. Reagents and Materials6.1 NaA Powder4, as reference standard, preferably with amean particle diameter of 3 to 5 microns (mean crystal size 1
17、to 2 microns).7. Procedure7.1 Carry out the steps (described in 7.1.1-7.1.3) in anidentical manner for both the sample and the NaA reference.7.1.1 Place about 1.5 g of finely divided sample in thedrying oven at 100C for 2 h. Cool the sample in the hydratorand hold there at room temperature and about
18、 58 % relativehumidity for at least 16 h.NOTE 1Grinding of course-textured samples should be done gently.Over-grinding can lead to breaking up of fine crystals and destruction ofthe zeolite.NOTE 2Drying followed by rehydration results in filling the zeolitepores with water of hydration but without a
19、n excess of moisture residingon the surface of the zeolite particles.7.1.2 Pack the sample into an XRD sample holder.7.1.3 Obtain an XRD pattern of the NaA reference byscanning over the angle range from 11 to 32 2u at 0.25/min.In the step mode, a 0.02 2u step for 2 s may be acceptable forpure NaA, w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD53572003STANDARDTESTMETHODFORDETERMINATIONOFRELATIVECRYSTALLINITYOFZEOLITESODIUMABYXRAYDIFFRACTION

链接地址:http://www.mydoc123.com/p-519564.html