ASTM D5319-1997(2008)e1 Standard Specification for Glass-Fiber Reinforced Polyester Wall and Ceiling Panels《玻璃纤维增强聚酯墙板和天花板的标准规范》.pdf
《ASTM D5319-1997(2008)e1 Standard Specification for Glass-Fiber Reinforced Polyester Wall and Ceiling Panels《玻璃纤维增强聚酯墙板和天花板的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5319-1997(2008)e1 Standard Specification for Glass-Fiber Reinforced Polyester Wall and Ceiling Panels《玻璃纤维增强聚酯墙板和天花板的标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5319 97 (Reapproved 2008)e1An American National StandardStandard Specification forGlass-Fiber Reinforced Polyester Wall and Ceiling Panels1This standard is issued under the fixed designation D 5319; the number immediately following the designation indicates the year oforiginal adoptio
2、n or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEEditorial changes were made throughout in April 2008.1. Scope*1.1 This specifica
3、tion covers the classification, materials ofconstruction, workmanship, physical requirements, and meth-ods of testing glass-fiber-reinforced polyester composite walland ceiling panels intended for use in light construction andsemi-structural applications.1.2 Supplementary information on chemical res
4、istance, im-pact resistance, and installation practice are provided in Ap-pendix X1.1.3 The classification of these composite panels into classesbased on relative response to a laboratory test shall not beconsidered a fire-hazard classification.1.4 Laboratory flammability tests (Test Methods E 84 an
5、dD 1929) applicable to this specification should be used tomeasure and describe the properties of materials, products, orassemblies in response to heat and flame under controlledlaboratory conditions and should not be used to describe orappraise the fire hazard or conditions. However, results may be
6、used as elements of a fire risk assessment which takes intoaccount all of the factors which are pertinent to an assessmentof the fire hazard of a particular end use.1.5 The intent of this specification is to define the class,grade, and general laminate properties of the composite walland ceiling lin
7、er panels in order to ensure a quality productwhich will perform in the intended application. This specifi-cation is not intended to restrict or limit technological changesaffecting performance when changes are agreed upon betweenthe purchaser and manufacturer.1.6 The values stated in inch-pound uni
8、ts are to be regardedas the standard. The values given in parentheses are providedfor information only.1.7 The text of this specification references notes andfootnotes that provide explanatory material. These notes andfootnotes (excluding those in Tables and Figures) shall not beconsidered as requir
9、ements of this specification.1.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations
10、 prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2D 374 Test Methods for Thickness of Solid Electrical Insu-lationD 618 Practice for Conditioning Plastics for TestingD 883 Terminology Relating to PlasticsD 1600 Terminology for Abbreviate
11、d Terms Relating toPlasticsD 1929 Test Method for Determining Ignition Temperatureof PlasticsD 2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesD 3029 Test Methods for Impact Resistance of Flat RigidPlastic Specimens by Means of a Tu
12、p (Falling Weight)3D 4968 Guide for Annual Review of Test Methods andSpecifications for PlasticsE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE 631 Terminology of Building Constructions3. Terminology3.1 GeneralDefinitions are in accordance with Terminolo-gies D 883 and E 63
13、1 and abbreviations with TerminologyD 1600, unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 camber, nnon-linearity of the long axis of a panel.NOTE 2In the process of water jet, knife, saw, or rotary sheartrimming of a continuous panel, sidewards motion of the pan
14、el through thecutting medium can be induced by imbalances in the system. The resultingtrim cuts, although maintaining parallelism between the long sides, maydescribe a continuous curve, rather than a straight line along the long axis1This specification is under the jurisdiction of ASTM Committee D20
15、 onPlastics and is the direct responsibility of Subcommittee D20.24 on Plastic BuildingProducts.Current edition approved March 1, 2008. Published April 2008. Originallyapproved in 1992. Last previous edition approved in 2001 as D 5319 97(2001).2For referenced ASTM standards, visit the ASTM website,
16、www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr
17、Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.of the panel. Imbalances in side-to-side cure rates or material distributionmay also produce this phenomenon. This curvature of the long axis maycreate problems with installation of the panel. Limits are placed on thedegree o
18、f non-linearity to minimize those problems.4. Classification4.1 The panels covered by this specification are divided intofour classifications based on relative response to the laboratoryflammability of Test Method E84.4.1.1 Class AFlame spread index 0 to 25, smoke devel-opment index of 450 or less.4
19、.1.2 Class BFlame spread index 26 to 75, smoke devel-opment index of 450 or less.4.1.3 Class CFlame spread index 76 to 200, smokedevelopment index of 450 or less.4.1.4 Class DGeneral purpose, no flame spread or smokedevelopment indices.NOTE 3Refer to 1.3 on flammability testing and fire hazard class
20、ifi-cation.4.2 These classifications may be further subdivided intogrades based on nominal thickness when tested in accordancewith 8.4:4.2.1 Grade 10.027 to 0.033 in. (0.69 to 0.84 mm); 0.030in. nominal (0.76 mm).4.2.2 Grade 20.036 to 0.044 in. (0.91 to 1.12 mm); 0.040in. nominal (1.02 mm).4.2.3 Gra
21、de 30.040 to 0.050 in. (1.02 to 1.27 mm); 0.045in. nominal (1.14 mm).4.2.4 Grade 40.054 to 0.066 in. (1.37 to 1.68 mm); 0.060in. nominal (1.52 mm).4.2.5 Grade 50.067 to 0.083 in. (1.70 to 2.11 mm); 0.075in. nominal (1.91 mm).4.2.6 Grade 60.081 to 0.099 in. (2.06 to 2.51 mm); 0.090in. nominal (2.29 m
22、m).4.2.7 Grade 70.108 to 0.132 in. (2.74 to 3.35 mm); 0.120in. nominal (3.05 mm).4.3 Within the classification of grade and class of compositepanel described in this specification are commercial productswith the following variations as agreed upon between thepurchaser and manufacturer.4.3.1 Size (Le
23、ngth and Width)The nominal sizes availableare 23.75 in. (603.25 mm) to 120 in. (3048 mm) in width and47.75 in. (1212.85 mm) to 500 continuous feet of coil stock(152 m) in length.4.3.2 ThicknessThe nominal thicknesses available are0.0303 in. (0.77 mm) to 0.120 in. (3.05 mm).4.3.3 ColorRefer to manufa
24、cturers literature for therange of colored product available.4.3.4 SurfaceThe two most popular surfaces available aretextured and smooth.5. Materials5.1 The polyester resin used in the composite shall be athermosetting polyester resin with cross-linking monomerscomposed of polymeric esters in which
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD531919972008E1STANDARDSPECIFICATIONFORGLASSFIBERREINFORCEDPOLYESTERWALLANDCEILINGPANELS 玻璃纤维 增强

链接地址:http://www.mydoc123.com/p-519463.html