《ASTM D5200-2003 Standard Test Method for Determination of Weight Percent Volatile Content of Solvent-Borne Paints in Aerosol Cans《测定气溶胶瓶中溶剂型漆挥发物质重量百分比的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5200-2003 Standard Test Method for Determination of Weight Percent Volatile Content of Solvent-Borne Paints in Aerosol Cans《测定气溶胶瓶中溶剂型漆挥发物质重量百分比的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5200 03Standard Test Method forDetermination of Weight Percent Volatile Content of Solvent-Borne Paints in Aerosol Cans1This standard is issued under the fixed designation D 5200; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is for the determination of the weightpercent volatile organic compounds of
3、solvent-borne paints inaerosol cans. It offers a unique way to obtain paint specimensfrom aerosol cans.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and h
4、ealth practices and determine the applica-bility of regulatory limitations prior to use. A specific hazardstatement is given in Note 1.2. Referenced Documents2.1 ASTM Standards:E 145 Specification for Gravity-Convection and Forced-Ventilation Ovens2E 180 Practice for Determining the Precision of AST
5、MMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals32.2 Other Standard:Method 35 Determination of Percent Volatile Organic Com-pounds (VOC) in Solvent Based Aerosol Paints43. Summary of Test Method3.1 A designated quantity from an aerosol coating is sprayedinto an adapter glass
6、tube assembly and heated in an oven at110 6 5C for 60 min. The percent volatile is calculated fromthe loss in weight.4. Significance and Use4.1 This test method is the procedure of choice for deter-mining the volatile content in aerosol coatings under specifiedtest conditions modeled after Method 35
7、4. The inverse value,nonvolatile, is used to determine the weight percent solidscontent. This information is useful to the paint producer, user,and to environmental interests for determining the grams ofvolatile organic compounds per gram of solids emitted fromaerosol cans.5. Apparatus5.1 Adapter Gl
8、ass Tube Assembly, (Fig. 1).5.1.1 Sample Adapter Tube, straight connecting with 35/25spherical joints. Loosely fill with glass wool and preconditionfor 30 min in an oven at 110 6 5C and store in a dessicatorprior to use.5,61This test method is under the jurisdiction of ASTM Committee D01 on Paintand
9、 Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved Jan. 10, 2003. Published March 2003. Originallyapproved in 1991. Last previous edition approved in 1997 as D 5200 92 (1997
10、)e1.2Annual Book of ASTM Standards, Vol 14.04.3Annual Book of ASTM Standards, Vol 15.05.4Bay Area Air Quality Management District, (BAAQMD) Manual of Proce-dures, Vol III, 939 Ellis St., San Francisco, CA 94109.5The sole source of supply of the adapter tube, No. 5035-35 known to thecommittee at this
11、 time is Ace Glass Inc., P.O. Box 688, 1430 Northwest Blvd.,Vineland, NJ 08360.FIG. 1 Adapter Glass Tube Assembly1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.2 Charcoal Adapter Tube, straight connecting with35/25 spherical joi
12、nts. Fill with activated charcoal and plugboth ends with glass wool. This tube is used to prevent thesolvent vapors from contaminating the vacuum pump.6,75.1.3 Adapters, connecting hose with 35/25 socket joints.6,85.1.4 Adapter,6,9connecting hose with 35/25 ball joint.5.1.5 Clamps, pinch type, with
13、screw-locking device.6,105.1.6 Glass Wool, medium-fine silk.5.1.7 Activated Charcoal, coconut, 8 to 12 mesh.5.1.8 Tygon Tubing.5.1.9 Iron Stands.5.1.10 Utility Clamps.5.2 Vacuum Pump.5.3 Forced Draft Oven, Type II A or Type II B as specifiedin Specification E 145.5.4 Actuators (Valves), with extensi
14、on tubes.5.5 Top-Loading Balance, capable of weighing to 0.01 g.5.6 Shaker, similar to the Eberbach shaker in Fig. 2.6. Procedure6.1 Mix the aerosol can thoroughly using a shaker, similarto the Eberbach shaker in Fig. 2, for 15 min at the low-speedsetting. It is essential that the samples be well mi
15、xed to obtainvalid results.6.2 Weigh accurately to 0.01 g, a preconditioned sampleadapter tube. Use a pair of gloves at all times when handlingthe adapter glass tube.6.3 Remove the cap and actuator from the mixed can.Replace the actuator with one having an extension tube.6.4 Test actuator and extens
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD52002003STANDARDTESTMETHODFORDETERMINATIONOFWEIGHTPERCENTVOLATILECONTENTOFSOLVENTBORNEPAINTSINAEROSOLCANS

链接地址:http://www.mydoc123.com/p-519145.html