《ASTM D5167-2013 Standard Practice for Melting of Hot-Applied Joint and Crack Sealant and Filler for Evaluation《用于评估热用接缝 断开密封胶和填充物溶化的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5167-2013 Standard Practice for Melting of Hot-Applied Joint and Crack Sealant and Filler for Evaluation《用于评估热用接缝 断开密封胶和填充物溶化的标准操作规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5167 13Standard Practice forMelting of Hot-Applied Joint and Crack Sealant and Filler forEvaluation1This standard is issued under the fixed designation D5167; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice establishes the procedure for melting orheating, or both, of hot-applied joint and crack sealants andf
3、illers in preparation for the making of test specimens used inthe laboratory evaluations of the sealants and fillers. Refer tothe specific standard material specification for samplingrequirements, test sample quantity, temperatures and times formelting and heating, and the number of specimens requir
4、ed fortesting.1.2 This practice is applicable to the hot-applied joint andcrack sealants and fillers used in both portland cement andasphaltic-concrete pavements.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may
5、 not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 WARNING Mercury has been designated by EPA andmany state agencies as a hazardous material that can causecentral nervous s
6、ystem, kidney and liver damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAs website http:/www.epa.gov/mercu
7、ry/faq.htm - for additional infor-mation. Users should be aware that selling mercury and/ormercury containing products into your state may be prohibitedby state law.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of th
8、e user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautions see Section 7.2. Referenced Documents2.1 ASTM Standards:2D5535 Terminology Relating to Formed-in-Place Sealantsfor Joints and
9、 Cracks in Pavements (Withdrawn 2009)3E1 Specification for ASTM Liquid-in-Glass ThermometersE220 Test Method for Calibration of Thermocouples ByComparison TechniquesE171 Practice for Conditioning and Testing Flexible BarrierPackaging3. Terminology3.1 DefinitionsRefer to Terminology D5535 for defini-
10、tions of the following terms used in this specification: maxi-mum heating temperature, minimum application temperature.4. Significance and Use4.1 It is intended that this practice be used bymanufacturers, users, and testing agencies. The use of thispractice establishes a uniform procedure for the me
11、lting orheating of hot-applied sealants and fillers. It is not intended toestablish test procedures or conditions of test which areassociated with each of the joint sealants and fillers.5. Standard Conditions5.1 The laboratory atmospheric conditions, hereinafter re-ferred to as standard conditions,
12、shall be as detailed inSpecification E171,236 2C (73.4 6 3.6F) and 50 % relativehumidity 610 %. The material shall be conditioned for 24 h atstandard conditions before melting or heating.6. Apparatus6.1 Laboratory Melter:6.1.1 The equipment for melting of the joint sealant or fillershall be an oil j
13、acketed melter equipped with a mechanicalagitator for the oil bath and material in the melting vat.1This practice is under the jurisdiction of ASTM Committee D04 on Road andPaving Materials and is the direct responsibility of Subcommittee D04.33 onFormed In-Place Sealants for Joints and Cracks in Pa
14、vements.Current edition approved Jan. 1, 2013. Published February 2013. Originallyapproved in 1991. Last previous edition approved in 2013 as D5167 10. DOI:10.1520/D5167-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For A
15、nnual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Unit
16、ed States16.1.2 The heat transfer oil shall be a high flash point oil, thatis, in excess of 315C (600F).6.1.3 The heat source shall be thermostatically controlledand capable of maintaining the heat transfer oil temperaturewithin a tolerance of 63C (65F) and capable of heating theoil to a maximum of
17、288C (550F).6.1.4 The mechanical agitator speed for the material shall be30 6 5 rpm when fully loaded and the agitator speed for the oilbath shall be such to allow continuous circulation of the oil.6.1.5 Except when adding the sealant or filler sample, orchecking temperature, the melters pots shall
18、be covered withclose fitting lids.6.1.6 Refer to Fig. 1 and Fig. 2 (bottom discharge type) andFig. 3 (removable can type) for typical laboratory melters.Alsosee Note 1.6.1.7 The thermometric device shall be a Type K thermo-couple with resolution of 1C and the calibration verified inaccordance with T
19、est Method E220 at least once per year. UseFIG. 1 Detailed Drawing of Joint Sealant Laboratory Melting UnitD5167 132a liquid in glass thermometer, such as the 2F or 2C thermom-eters conforming to Specification E1 or temperature measuringdevices such as platinum resistance thermometers that provideeq
20、uivalent or better accuracy and precision, as the referencethermometer with the Thermocouples in Stirred Liquid Bathsprocedure. The reference thermometer traceability shall beestablished through a national metrology institution. Also seeNote 2.NOTE 1The removable can type melter as shown in Fig. 3 i
21、s verysimilar in design to the melter shown in Fig. 1 and Fig. 2. Fig. 3s pots aredesigned to be removed so the melted material can be poured. Extra caremust be taken when using this type of melter. Check the manufacturersrecommended safety procedures before use.NOTE 2NIST is a national metrology in
22、stitution.7. Precautions7.1 Prior to beginning sampling and heating of sealants orfillers, a Material Safety Data Sheet must be obtained from thesealant or filler manufacturer so that proper safe handlingtechniques will be used.7.2 Maximum Heating TemperatureIt is imperative thatthe manufacturers ma
23、ximum heating temperatures be obtainedfor the material to be evaluated. The temperature of thematerial must not exceed the maximum heating temperature.7.3 The laboratory melter unit should be located under anexhaust hood to disperse fumes.7.4 Joint/crack sealants and fillers are manufactured from av
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD51672013STANDARDPRACTICEFORMELTINGOFHOTAPPLIEDJOINTANDCRACKSEALANTANDFILLERFOREVALUATION 用于 评估 接缝

链接地址:http://www.mydoc123.com/p-519042.html