ASTM D5088-2015a Standard Practice for Decontamination of Field Equipment Used at Waste Sites《在废弃物场地上使用现场设备净化的标准实施规程》.pdf
《ASTM D5088-2015a Standard Practice for Decontamination of Field Equipment Used at Waste Sites《在废弃物场地上使用现场设备净化的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5088-2015a Standard Practice for Decontamination of Field Equipment Used at Waste Sites《在废弃物场地上使用现场设备净化的标准实施规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5088 15aStandard Practice forDecontamination of Field Equipment Used at Waste Sites1This standard is issued under the fixed designation D5088; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers the decontamination of field equip-ment used in the sampling of soils, soil gas, sludges, surfacewater, and gr
3、oundwater at waste sites which are to undergoboth physical and chemical analyses.1.2 This practice is applicable only at sites where chemical(organic and inorganic) wastes are a concern. It is not intendedfor use at radiological, mixed (chemical and radiological), orbiohazard sites. This practice do
4、es not address regulatoryrequirements for the handling, labeling, shipping, or storing ofwastes or samples.1.3 Practices are included for the decontamination of equip-ment which comes into contact with the sample matrix (samplecontacting equipment) and for ancillary equipment that has notcontacted t
5、he portion of sample to be analyzed (non-samplecontacting equipment), but which must be cleaned to avoidspreading of contamination.1.4 This practice is intended for use when field equipmentused for sampling will be decontaminated in the field orreturned from the field. Information on the constructio
6、n of fielddecontamination facilities and non-sample contacting equip-ment decontamination is also provided.1.5 This practice is based on commonly recognized methodsby which equipment may be decontaminated. The practicesdescribed for sample contacting equipment are commonlyprescribed. Background stud
7、ies are included in the Referencesat the end of this standard (12345). The user is reminded of theimportance of proper decontamination planning to minimizethe amount of decontamination wastes generated and to reduceor eliminate the use of cleaning agents that are themselveshazardous. Quality Assuran
8、ce/Quality Control (QA/QC)samples that document decontamination effectiveness can beused to modify or enhance decontamination techniques. De-contamination at radiologically contaminated sites should referto Practice D5608.1.6 This practice is applicable to most conventional sam-pling equipment const
9、ructed of metallic and synthetic materi-als. The manufacturer of a specific sampling apparatus shouldbe contacted or the manufacturers manuals reviewed if there isconcern regarding the reactivity of a decontamination rinsingagent or the temperatures that could affect the equipment.Plastic components
10、 and gasket materials could be damaged bysome of the stronger reagents or high temperatures.1.7 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.8 This practice offers an organized collection of informa-tion or a series of opti
11、ons and does not recommend a specificcourse of action. This document cannot replace education orexperience and should be used in conjunction with professionaljudgment. Not all aspects of this practice may be applicable inall circumstances. This ASTM standard is not intended torepresent or replace th
12、e standard of care by which theadequacy of a given professional service must be judged, norshould this document be applied without consideration of aprojects many unique aspects. The word “Standard” in thetitle of this document means only that the document has beenapproved through the ASTM consensus
13、 process.1.9 This standard does not purport to address the safetyproblems associated with its use. It is the responsibility of theuser of this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2
14、.1 ASTM Standards:2D653 Terminology Relating to Soil, Rock, and ContainedFluidsD5608 Practices for Decontamination of Field EquipmentUsed at Low Level Radioactive Waste Sites3. Terminology3.1 Definitions:1This practice is under the jurisdiction of ASTM Committee D18 on Soil andRock and is the direct
15、 responsibility of Subcommittee D18.21 on Groundwater andVadose Zone Investigations.Current edition approved Aug. 1, 2015. Published August 2015. Originallyapproved in 1990. Last previous edition approved in 2015 as D5088 15. DOI:10.1520/D5088-15A.2For referenced ASTM standards, visit the ASTM websi
16、te, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Dr
17、ive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.1 For definitions of general technical terms used withinthis Practice refer to Terminology D653.3.2 Definitions Specific to this Practice:3.2.1 equipment rinsate blanka sample collected by usinganalyte-free water rinsed over/throu
18、gh equipment that has beendecontaminated, and is analyzed for the parameters of interest.3.2.2 field cleaningthe process of cleaning dirty samplingequipment so it can be returned or moved to a final decontami-nation in a condition that will minimize the potential ofcontaminant transfer from a site.
19、At a minimum, this shouldconsist of washing with soap and water, and rinsing with tapwater.3.2.3 sample contacting equipmentequipment that comesin direct contact with the sample or portion of sample that willundergo chemical analyses or physical testing (for example, abailer used to sample a groundw
20、ater well, split-spoon sampler,soil gas sampling probe, tubing used to bring a groundwatersample to the surface, etc.).4. Summary of Practice4.1 When decontaminating equipment, the user will need toevaluate whether the equipment materials are plastics ormetals, the types of contaminants (inorganic v
21、s. organic) thatwill be analyzed for, whether the equipment contacts thesample, the type of exposure (for example, whether exposed tooils, grease, tars, soils, or simply water), and the data-qualityobjectives. These issues will help to determine the practices tobe used to decontaminate the equipment
22、. The decontaminationprocess should use the minimum effort and materials demon-strated to satisfy that the required decontamination has beenachieved. The use of hazardous materials should be used onlywhen additional rinses, heat, and other techniques have beenfound inadequate and the equipment canno
23、t be substituted withdisposable or dedicated equipment.4.2 Two different practices are presented for the decontami-nation of sample-contacting and non-sample contacting equip-ment. The practices have been developed based on a review ofresearch studies, current state and federal guidelines. Ingeneral
24、, sample contacting equipment should be washed with adetergent solution followed by a series of control water anddeionized water rinses. Non-sample contacting equipmentshould be washed with water or without a detergent solutiondepending on the type and degree of contaminants and rinsedwith control w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD50882015ASTANDARDPRACTICEFORDECONTAMINATIONOFFIELDEQUIPMENTUSEDATWASTESITES 废弃物 地上 使用 现场 设备 净化 标准

链接地址:http://www.mydoc123.com/p-518840.html