1、Designation: D 5088 02 (Reapproved 2008)Standard Practice forDecontamination of Field Equipment Used at Waste Sites1This standard is issued under the fixed designation D 5088; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the decontamination of field equip-ment used in the sampling of soils, soil gas, sludges, su
3、rfacewater, and ground water at waste sites which are to undergoboth physical and chemical analyses.1.2 This practice is applicable only at sites where chemical(organic and inorganic) wastes are a concern. It is not intendedfor use at radiological, mixed (chemical and radiological), orbiohazard site
4、s.1.3 Procedures are included for the decontamination ofequipment which comes into contact with the sample matrix(sample contacting equipment) and for ancillary equipmentthat has not contacted the portion of sample to be analyzed(non-sample contacting equipment).1.4 This practice is based on commonl
5、y recognized methodsby which equipment may be decontaminated. The proceduresdescribed for sample contacting equipment are commonlyprescribed, however there is a minimum of scientific data thatsupports these methods (Mickam et al. 19892, Parker34, 1995).Therefore the user is reminded of the importanc
6、e of QA/QCsamples that document decontamination effectiveness and thatthese samples can be used to modify or enhance decontamina-tion techniques. Decontamination at radiologically contami-nated sites should refer to Practice D 5608.1.5 This practice is applicable to most conventional sam-pling equip
7、ment constructed of metallic and synthetic materi-als. The manufacturer of a specific sampling apparatus shouldbe contacted if there is concern regarding the reactivity of adecontamination rinsing agent with the equipment.1.6 This practice offers an organized collection of informa-tion or a series o
8、f options and does not recommend a specificcourse of action. This document cannot replace education orexperience and should be used in conjunction with professionaljudgement. Not all aspects of this practice may be applicable inall circumstances. This ASTM standard is not intended torepresent or rep
9、lace the standard of care by which theadequacy of a given professional service must be judged, norshould this document be applied without consideration of aprojects many unique aspects. The word “Standard” in thetitle of this document means only that the documents has beenapproved through the ASTM c
10、onsensus process1.7 This standard does not purport to address the safetyproblems associated with its use. It is the responsibility of theuser of this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Doc
11、uments2.1 ASTM Standards:5D 653 Terminology Relating to Soil, Rock, and ContainedFluidsD 5608 Practices for Decontamination of Field EquipmentUsed at Low Level Radioactive Waste Sites3. Terminology3.1 Definitions:3.1.1 contaminantan undesirable substance not normallypresent or an unusually high conc
12、entration of a naturallyoccurring substance in water or soil.3.1.2 control rinse waterwater used for equipment wash-ing and rinsing having a known chemistry.3.1.3 decontaminationthe process of removing or reduc-ing to a known level undesirable physical or chemical constitu-ents, or both, from a samp
13、ling apparatus to maximize therepresentativeness of physical or chemical analyses proposedfor a given sample.3.1.4 non-sample contacting equipmentrelated equipmentassociated with the sampling effort, but that does not directlycontact the sample (for example, augers, drilling rods, excava-tions machi
14、nery).1This practice is under the jurisdiction of ASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.21 on Ground Water andVadose Zone Investigations .Current edition approved Sept. 15, 2008. Published October 2008. Originallyapproved in 1990. Last previous editi
15、on approved in 2002 as D 5088 02.2Mickam, J. T., Bellandi, R., and Tifft, Jr., E. C., Equipment DecontaminationProcedures for Ground Water and Vadose Zone Monitoring Programs: Status andProspects, Ground Water Monitoring Review, Vol 9, No. 2, 1989, pp. 100121.3Parker, L. V., A Literature Review on D
16、econtaminating Groundwater SamplingDevices: Organic Contaminates, CRREL Report 9514, U.S. Army Cold RegionsResearch and Engineering Laboratory, Hanover, NH, 1996.4Parker, L. V., and Ranney, T. A., Decontamination Materials Used in Ground-water Sampling Devices, CRREL Special Report 9724, U.S. Army C
17、old RegionsResearch and Engineering Laboratory, Hanover, NH, 1997a.5For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM we
18、bsite.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.5 quality assurance/quality control (QA/QC)the ef-forts completed to evaluate the accuracy and precision of asampling or testing procedure, or both.3.1.6 sample contacting equ
19、ipmentequipment that comesin direct contact with the sample or portion of sample that willundergo chemical analyses or physical testing (for example,ground water well bailer, split-spoon sampler, soil gas sam-pling probe).3.1.7 For definitions of other terms used in this practice, seeTerminology D 6
20、53.4. Summary of Practice4.1 Two different procedures are presented for the decon-tamination of sample-contacting and non-sample contactingequipment. The procedures have been developed based on areview of current state and federal guidelines, as well as asummary of commonly employed procedures. In g
21、eneral,sample contacting equipment should be washed with a deter-gent solution followed by a series of control water, desorbingagents and deionized water rinses. Nonsample contactingequipment should be washed with a detergent solution andrinsed with control water. Although such techniques may bediff
22、icult to perform in the field, they may be necessary to mostaccurately evaluate low concentrations of the chemical con-stituent(s) of interest.4.2 Prior to initiating a field program that will involveequipment decontamination, a site specific equipment decon-tamination protocol should be prepared fo
23、r distribution to theindividuals involved with the particular sampling program.Information to be presented in the protocol should include:4.2.1 Site location and description,4.2.2 Statement of the sampling program objective anddesired precision and accuracy, that is, is sampling effort forgross qual
24、itative evaluation or for trace concentration, param-eter specific evaluations,4.2.3 Summary of available information regarding soiltypes, hydrogeology and anticipated chemistry of the materialsto be sampled,4.2.4 Listing of equipment to be used for sampling andmaterials needed for decontamination,4
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD508820022008STANDARDPRACTICEFORDECONTAMINATIONOFFIELDEQUIPMENTUSEDATWASTESITES 放射性 废弃物 地上 现场 设备

链接地址:http://www.mydoc123.com/p-518838.html