《ASTM D5088-2002 Standard Practice for Decontamination of Field Equipment Used at Nonradioactive Waste Sites《在非放射性废弃物场地上用现场设备的净化的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5088-2002 Standard Practice for Decontamination of Field Equipment Used at Nonradioactive Waste Sites《在非放射性废弃物场地上用现场设备的净化的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5088 02Standard Practices forDecontamination of Field Equipment Used at Waste Sites1This standard is issued under the fixed designation D 5088; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers the decontamination of field equip-ment used in the sampling of soils, soil gas, sludges, surfacewater, and
3、 ground water at waste sites which are to undergoboth physical and chemical analyses.1.2 These practices are applicable only at sites wherechemical (organic and inorganic) wastes are a concern. It is notintended for use at radiological, mixed (chemical and radio-logical), or biohazard sites.1.3 Proc
4、edures are included for the decontamination ofequipment which comes into contact with the sample matrix(sample contacting equipment) and for ancillary equipmentthat has not contacted the portion of sample to be analyzed(non-sample contacting equipment).1.4 These practices are based on commonly recog
5、nizedmethods by which equipment may be decontaminated. Theprocedures described for sample contacting equipment arecommonly prescribed, however there is a minimum of scien-tific data that supports these methods (Mickam et al. 19892,Parker34, 1995). Therefore the user is reminded of the impor-tance of
6、 QA/QC samples that document decontaminationeffectiveness and that these samples can be used to modify orenhance decontamination techniques. Decontamination at ra-diologically contaminated sites should refer to PracticeD 5608.1.5 This practice is applicable to most conventional sam-pling equipment c
7、onstructed of metallic and synthetic materi-als. The manufacturer of a specific sampling apparatus shouldbe contacted if there is concern regarding the reactivity of adecontamination rinsing agent with the equipment.1.6 This practice offers an organized collection of informa-tion or a series of opti
8、ons and does not recommend a specificcourse of action. This document cannot replace education orexperience and should be used in conjunction with professionaljudgement. Not all aspects of this practice may be applicable inall circumstances. This ASTM standard is not intended torepresent or replace t
9、he standard of care by which theadequacy of a given professional service must be judged, norshould this document be applied without consideration of aprojects many unique aspects. The word “Standard” in thetitle of this document means only that the documents has beenapproved through the ASTM consens
10、us process1.7 This standard does not purport to address the safetyproblems associated with its use. It is the responsibility of theuser of this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents
11、2.1 ASTM Standards:D 653 Terminology Relating to Soil, Rock, and ContainedFluids5D 5608 Practice for Decontamination of Field EquipmentUsed at Low Level Radioactive Waste Sites53. Terminology3.1 Definitions:3.1.1 contaminantan undesirable substance not normallypresent or an unusually high concentrat
12、ion of a naturallyoccurring substance in water or soil.3.1.2 control rinse waterwater used for equipment wash-ing and rinsing having a known chemistry.3.1.3 decontaminationthe process of removing or reduc-ing to a known level undesirable physical or chemical constitu-ents, or both, from a sampling a
13、pparatus to maximize therepresentativeness of physical or chemical analyses proposedfor a given sample.3.1.4 non-sample contacting equipmentrelated equipmentassociated with the sampling effort, but that does not directlycontact the sample (for example, augers, drilling rods, excava-tions machinery).
14、3.1.5 quality assurance/quality control (QA/QC)the ef-forts completed to evaluate the accuracy and precision of asampling or testing procedure, or both.1This practice is under the jurisdiction of ASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.21 on Ground Wat
15、er andVadose Zone Investigations.Current edition approved Jan. 10, 2002. Published April 2002 Originallypublished as D 508890. Last previous edition D 508890.2Mickam, J.T., R. Bellandi, and E.C. Tifft, Jr., 1989, Equipment Decontamina-tion Procedures for Ground Water and Vadose Zone Monitoring Progr
16、ams: Statusand Prospects, Ground Water Monitoring Review 9, No 2:100121.3Parker, L.V., 1996A Literature Review on Decontaminating GroundwaterSampling Devices: Organic Contaminates.CRREL Report 9514, U.S. Army ColdRegions Research and Engineering Laboratory, Hanover, NH.4Parker, L.V., and T.A. Ranney
17、, 1997a. Decontamination Materials Used inGroundwater Sampling Devices. CRREL Special Report 9724, U.S. Army ColdRegions Research and Engineering Laboratory, Hanover, NH.5Annual Book of ASTM Standards, Vol 04.08.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM Intern
18、ational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.6 sample contacting equipmentequpiment that comesin direct contact with the sample or portion of sample that willundergo chemical analyses or physical testing (for example,ground water well bailer, split
19、-spoon sampler, soil gas sam-pling probe).3.1.7 For definitions of other terms used in this practice, seeTerminology D 653.4. Summary of Practice4.1 Two different procedures are presented for the decon-tamination of sample-contacting and non-sample contactingequipment. The procedures have been devel
20、oped based on areview of current state and federal guidelines, as well as asummary of commonly employed procedures. In general,sample contacting equipment should be washed with a deter-gent solution followed by a series of control water, desorbingagents and deionized water rinses. Nonsample contacti
21、ngequipment should be washed with a detergent solution andrinsed with control water. Although such techniques may bedifficult to perform in the field, they may be necessary to mostaccurately evaluate low concentrations of the chemical con-stituent(s) of interest.4.2 Prior to initiating a field progr
22、am that will involveequipment decontamination, a site specific equipment decon-tamination protocol should be prepared for distribution to theindividuals involved with the particular sampling program.Information to be presented in the protocol should include:4.2.1 Site location and description,4.2.2
23、Statement of the sampling program objective anddesired precision and accuracy, that is, is sampling effort forgross qualitative evaluation or for trace concentration, param-eter specific evaluations,4.2.3 Summary of available information regarding soiltypes, hydrogeology and anticipated chemistry of
24、 the materialsto be sampled,4.2.4 Listing of equipment to be used for sampling andmaterials needed for decontamination,4.2.5 Detailed step by step procedure for equipment decon-tamination for each piece or type of equipment to be utilizedand procedures for rinse fluids containment and disposal asapp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD50882002STANDARDPRACTICEFORDECONTAMINATIONOFFIELDEQUIPMENTUSEDATNONRADIOACTIVEWASTESITES 放射性 废弃物

链接地址:http://www.mydoc123.com/p-518837.html