《ASTM D5055-2011 Standard Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-Joists《预制1型木格栅的结构能力的建立和监控技术标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5055-2011 Standard Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-Joists《预制1型木格栅的结构能力的建立和监控技术标准规范》.pdf(33页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5055 11Standard Specification forEstablishing and Monitoring Structural Capacities ofPrefabricated Wood I-Joists1This standard is issued under the fixed designation D5055; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 GeneralThis specification gives procedures for estab-lishing, monitoring, and reevaluating structural c
3、apacities ofprefabricated wood I-joists. Capacities considered are shear,reaction, moment, and stiffness. Procedures for establishingcommon details are given and certain design considerationsspecific to wood I-joists are itemized.1.2 Contents of the StandardAn index and brief descrip-tion of the mai
4、n features of this specification are given inX1.1.1.1.3 Development of the StandardThe development andintent of this specification is discussed in Appendix X1.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI un
5、its that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine
6、 the applica-bility of regulatory limitations prior to use. A specific precau-tionary statement is given in 6.1.1.5.2. Referenced Documents2.1 ASTM Standards:2D198 Test Methods of Static Tests of Lumber in StructuralSizesD245 Practice for Establishing Structural Grades and Re-lated Allowable Propert
7、ies for Visually Graded LumberD1990 Practice for Establishing Allowable Properties forVisually-Graded Dimension Lumber from In-Grade Testsof Full-Size SpecimensD2559 Specification for Adhesives for Bonded StructuralWood Products for Use Under Exterior Exposure Condi-tionsD2915 Practice for Sampling
8、and Data-Analysis for Struc-tural Wood and Wood-Based ProductsD4761 Test Methods for Mechanical Properties of Lumberand Wood-Base Structural MaterialD5456 Specification for Evaluation of Structural CompositeLumber ProductsD5457 Specification for Computing Reference Resistanceof Wood-Based Materials
9、and Structural Connections forLoad and Resistance Factor DesignD7247 Test Method for Evaluating the Shear Strength ofAdhesive Bonds in Laminated Wood Products at ElevatedTemperaturesD7480 Guide for Evaluating the Attributes of a ForestManagement PlanE4 Practices for Force Verification of Testing Mac
10、hinesE529 Guide for Conducting Flexural Tests on Beams andGirders for Building ConstructionE699 Practice for Evaluation of Agencies Involved in Test-ing, Quality Assurance, and Evaluating of Building Com-ponentsIEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI): The Modern Met
11、ric System2.2 U.S. Product Standards:3PS-1 Structural PlywoodPS-2 Performance Standard for Wood-Based Structural-UsePanelsPS-20 American Softwood Lumber Standard2.3 Other Standards:CSA O86 Engineering Design in Wood4CSA Standards for Wood Adhesives O112 Series4CSA O121 Douglas-fir Plywood4CSA O141 S
12、oftwood Lumber4CSA O151 Canadian Softwood Plywood4CSA O325 Construction Sheathing4CSA O437.0 OSB and Waferboard41This specification is under the jurisdiction of ASTM Committee D07 on Woodand is the direct responsibility of Subcommittee D07.02 on Lumber and EngineeredWood Products.Current edition app
13、roved May 1, 2011. Published June 2011. Originallyapproved in 1990. Last previous edition approved in 2010 as D5055 10. DOI:10.1520/D5055-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volu
14、me information, refer to the standards Document Summary page onthe ASTM website.3Available from APAThe Engineered Wood Association, 7011 South 19thStreet, Tacoma, WA98466, http:/www.apawood.org; and TECO, 2902 Terra Court,Sun Prairie, WI 53590, http:/.4Available from Canadian Standards Association (
15、CSA), 5060 Spectrum Way,Mississauga, ON L4W 5N6, Canada, http:/www.csa.ca.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Lumber Grading Rules Approved by American LumberStandards Committee (ALSC) or Canadian Lumber Stan-dards Accred
16、itation Board (CLSAB)5SPS-1 Fingerjoined Structural Lumber6SPS-4 Fingerjointed Flange Stock Lumber, 200163. Terminology3.1 Definition:3.1.1 prefabricated wood I-joista structural membermanufactured using sawn or structural composite lumberflanges and structural panel webs, bonded together with exte-
17、rior exposure adhesives, forming an “I” cross-sectional shape.These members are primarily used as joists in floor and roofconstruction.3.2 Definitions of Terms Specific to This Standard:3.2.1 capacity (or structural capacity)the numeric resultof certain calculations specified in this specification.3
18、.2.2 design valuethe numeric value claimed by themanufacturer as appropriate for use in structural analysis.NOTE 1A brief discussion of this issue is found in X1.9.3.2.3 structural composite lumbera composite of woodelements (for example, wood strands, strips, veneer sheets, ora combination thereof)
19、, bonded with an exterior grade adhesiveand intended for structural use in dry service conditions.4. Design Considerations4.1 Design Value Adjustments:4.1.1 Duration of LoadWith the exception of reactiondesign values limited by compression perpendicular to grain,prefabricated wood I-joists shall be
20、designed using the strengthadjustment for load duration used in sawn lumber. Thisadjustment is determined in accordance with the section onDuration of Load Under Modification of Allowable Propertiesfor Design Use in Practice D245.4.1.2 Repetitive MembersThe repetitive member factorfor prefabricated
21、I-joists shall be taken as 1.0.NOTE 2Committee D07 chose to reduce the repetitive member factorto unity primarily for purposes of design simplicity. A discussion of thisdecision is given in Appendix X1.4.1.3 TreatmentsSome pressure treatments affect materialstrength and the quality of prefabricated
22、wood I-joists. TreatedI-joists shall not be used without evaluation of such effects.4.1.4 EnvironmentThe capacities developed in this speci-fication are applicable to joists used under dry conditions suchas in most covered structures.Appropriate adjustments for usesin other environments shall be mad
23、e.4.2 Shear Design:4.2.1 Neglecting loads within a distance from the supportequal to the depth of the member shall not be permitted.4.2.2 Adjustments to the shear design value near the supportor at locations of continuity or where reinforcements areprovided must be substantiated by independent testi
24、ng to thegeneral intended criteria for shear capacity herein.5. Materials5.1 GeneralThe following I-joist components meet thedefinition of a biobased product in accordance with 3.3.1 ofGuide D7480:5.1.1 Lumber flange materials complying with USDOCPS-20, CSA O141, NLGA SPS-1, or NLGA SPS-4.5.1.2 Stru
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD50552011STANDARDSPECIFICATIONFORESTABLISHINGANDMONITORINGSTRUCTURALCAPACITIESOFPREFABRICATEDWOODIJOISTS

链接地址:http://www.mydoc123.com/p-518743.html