ASTM D5007-1999(2013) Standard Test Method for Wet-to-Dry Hiding Change《湿到干遮盖变化的标准试验方法》.pdf
《ASTM D5007-1999(2013) Standard Test Method for Wet-to-Dry Hiding Change《湿到干遮盖变化的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5007-1999(2013) Standard Test Method for Wet-to-Dry Hiding Change《湿到干遮盖变化的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5007 99 (Reapproved 2013)Standard Test Method forWet-to-Dry Hiding Change1This standard is issued under the fixed designation D5007; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number
2、in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the changein hiding power of an architectural coating during drying, byvisual evaluation of the w
3、et and dry film.1.2 This test method is not recommended for colors otherthan white and tints.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, a
4、ssociated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2805 Test Method for Hiding Power of Paints by Reflec
5、-tometryD3924 Specification for Environment for Conditioning andTesting Paint, Varnish, Lacquer, and Related Materials3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 hiding index (hS), nthe Spreading Index at a stan-dard film opacity.3.1.1.1 DiscussionIn this test method the l
6、atter is a visualcontrast standard prepared by applying a semi-opaque whitecoating on a black and white hiding-power chart to give acontrast ratio of 0.98 (98 %) which is just short of completehiding, and is the conventional so-called full hiding end pointin photometric hiding-power methods such as
7、Test MethodD2805. Refer to the hiding indices of the wet and dry films ashSWand hSDrespectively.Since this test method is intended to measure hiding-powerdifference rather than hiding power itself, a 0.98 (98 %)contrast ratio standard is not required. It is necessary only thatthe same standard be us
8、ed for measuring both wet and dryfilms. See 3.1.8. For this purpose the standard needs to liewithin the contrast range of both the wet and dry stripes, whichis true of the 0.98 (98 %) contrast-ratio standard for mostcommercial paints. With paints of unusually low hiding, alower contrast standard may
9、 be required, which can be simplyone of the stripes taken from a drawdown of the test paint.3.1.2 hiding power, nthe spreading rate of a paint applieduniformly on a standard black and white hiding power chart togive a standard degree of contrast just short of complete hiding.3.1.2.1 DiscussionIn ref
10、lectometry the standard contrastfor hiding power measurements is generally accepted as thecontrast ratio C = 0.98 (98 %), which with white and lighttinted coatings is equivalent to a visual color difference ofabout 0.75 CIELAB units. That amount of color difference canreasonably be described as “jus
11、t-short-of complete-hiding.”Since this is a visual method it employs a visual comparator asa standard, which is a hiding power chart with a white coatingapplied at a contrast ratio of 0.98 (98 %).3.1.3 logicator, na multi-notch applicator with clearances,and corresponding wet film thicknesses and sp
12、reading rates, inequal percentage steps.3.1.4 logicator scale, na scale with values directly relatedto the logarithms of corresponding spreading rates.3.1.4.1 DiscussionA specified change in scale value rep-resents the same percentage change in spreading rate over anypart of such a scale.3.1.5 sprea
13、ding index (h), nthe spreading rate expressedin logicator scale units (LU) as described in 3.1.4 and 3.1.7.3.1.6 spreading rate (H), nthe area covered per unitquantity of coating.3.1.6.1 DiscussionIn this test method the quantity isvolumetric.3.1.7 TG19 logicator, na logicator designed for this test
14、method with eight notches numbered at four-unit intervals on ascale from 20 to 48, the notch clearances ranging from 67 to264 m (2.65 to 10.4 mils) corresponding to wet film thick-nesses from 37 to 145 m (1.46 to 5.7 mils) and spreading rates1This test method is under the jurisdiction of ASTM Commit
15、tee D01 on Paintand Related Coatings, Materials, andApplications and is the direct responsibility ofSubcommittee D01.42 on Architectural Coatings.Current edition approved May 15, 2013. Published May 2013. Originallyapproved in 1989. Last previous edition approved in 2008 as D5007 99 (2008).DOI: 10.1
16、520/D5007-99R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor
17、 Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1from 6.9 to 27 m2/L (280 to 1100 ft2/gal), with one scale unitrepresenting a change of 5 % and the four-unit interval betweennotches a cumulative change of 21.55 % in the clearance andcorresponding film thicknesses and spreading ra
18、tes. Refer tothis scale unit as a logicator unit (LU). (See Fig. 1.)3.1.7.1 DiscussionThe percentage difference betweennotches is calculated as (1.054 1) 100 = 21.55. This per-centage is applicable precisely to the notch clearances andapproximately to their related wet-film thicknesses and spread-in
19、g rates. The detailed relationships between scalar value andthe notch clearance, wet film thickness, and spreading rate aregiven in Table 1 and Table 2.3.1.8 wet-to-dry hiding change (WDHC), nthe differencein the Hiding Index of a paint between the wet and the drystate, expressed in logicator units
20、(LU) as follows:WDHC 5 hS5 hSD2 hSW(1)3.1.8.1 DiscussionThe WDHC is unchanged if the con-trast level of the hiding standard is varied, because the resultantchanges in the two hiding power values are proportional andtheir ratio therefore constant.3.1.8.2 DiscussionThe WDHC is unaffected by deviations
21、from the estimated film thickness/clearance ratio T/N (see Note1, Table 1), because the ratio of the two recalculated hiding-power values is unchanged.4. Summary of Test Method4.1 The test paint is applied with a TG19 Logicator on alogicator test chart (see 6.2 and Fig. 2) and the drawdownexamined i
22、n comparison with an agreed hiding standardimmediately after application and again after drying.4.2 The scale numbers of the wet and dry stripes that matchthe standard in contrast are recorded as the Wet Hiding Index,hSW, and the Dry Hiding Index hSD.4.3 The difference between the wet and dry hiding
23、 indices isrecorded as the wet-to-dry hiding change WDHC.4.4 If desired, the percent change in hiding power corre-sponding to the WDHC value is calculated and reported.5. Significance and Use5.1 Many architectural paints, particularly white and lighttints, change significantly in film opacity as the
24、y dry. Anincrease in hiding is sometimes associated with porosity andpoor film integrity with conventionally formulated coatings. Adecrease can result in a disappointing paint job. The wet-to-dryhiding change is therefore a property of great practical impor-tance.5.2 This test method can be used in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD500719992013STANDARDTESTMETHODFORWETTODRYHIDINGCHANGE 湿到干 遮盖 变化 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-518639.html