《ASTM D4993-2008(2014) Standard Practice for Calculation and Adjustment of Silica &40 SiO2&41 Scaling for Reverse Osmosis《反渗透用硅 (SiO2) 垢的计算和调整用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4993-2008(2014) Standard Practice for Calculation and Adjustment of Silica &40 SiO2&41 Scaling for Reverse Osmosis《反渗透用硅 (SiO2) 垢的计算和调整用标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4993 08 (Reapproved 2014)Standard Practice forCalculation and Adjustment of Silica (SiO2) Scaling forReverse Osmosis1This standard is issued under the fixed designation D4993; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the calculation and adjustment ofsilica (SiO2) for the concentrate stream of a
3、 reverse osmosissystem. The calculations are used to determine the need forscale control in the operation and design of reverse osmosisinstallations. This practice is applicable for all types of reverseosmosis devices (tubular, spiral wound, and hollow fiber).1.2 This practice is applicable to both
4、brackish waters andseawaters.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of th
5、is standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D859 Test Method for Silica in WaterD1067 Test Methods for Acidity or Alkalinity of WaterD1129 Terminology Relating to W
6、aterD1293 Test Methods for pH of WaterD3739 Practice for Calculation and Adjustment of theLangelier Saturation Index for Reverse OsmosisD4194 Test Methods for Operating Characteristics of Re-verse Osmosis and Nanofiltration DevicesD6161 Terminology Used for Microfiltration, Ultrafiltration,Nanofiltr
7、ation and Reverse Osmosis Membrane Processes3. Terminology3.1 DefinitionsFor definitions of terms relating to waterused in this practice, refer to Terminology D1129 and D6161.4. Summary of Practice4.1 This practice consists of calculating the potential forscaling by SiO2in a reverse osmosis concentr
8、ate stream fromthe concentration of SiO2in the feed solution and the recoveryof the reverse osmosis system.4.2 This practice also presents techniques to eliminatescaling by decreasing the recovery, decreasing the SiO2con-centration in the feedwater, adjusting the pH of the feedwater,and increasing t
9、he temperature of the feedwater.5. Significance and Use5.1 In the design and operation of reverse osmosisinstallations, it is important to predict the SiO2scaling prop-erties of the concentrate stream. Because of the increase in theconcentration of SiO2and the change in pH, the scalingproperty of th
10、e concentrate stream will be quite different fromthat of the feed solution. This practice permits the calculationof the scaling potential for the concentrate stream from thefeedwater analysis and the reverse osmosis operating param-eters.5.2 Scaling by SiO2will adversely affect the reverse osmo-sis
11、performance. This practice gives various procedures for theprevention of scaling.5.3 The presence of certain metals, for example, Al+3, maysignificantly alter the solubility of SiO2via formation ofinsoluble metal silicates. This practice does not address thisphenomena.6. Procedure6.1 Determine the c
12、oncentration of SiO2in the feed streamin accordance with Test Method D859.6.2 Measure the temperature of the feed solution.6.3 Measure the pH of the feed solution using Test MethodsD1293.NOTE 1If acid is used for control of CaCO3scale, measure the pHafter acid addition.6.4 Determine the total alkali
13、nity of the feed solution usingTest Methods D1067 and express as CaCO3.NOTE 2If acid is used for control of calcium carbonate (CaCO3) scale,determine the total alkalinity after acid addition.1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Su
14、bcommittee D19.08 on Membranes and IonExchange Materials.Current edition approved Jan. 1, 2014. Published March 2014. Originallyapproved in 1989. Last previous edition approved in 2008 as D4993 08. DOI:10.1520/D4993-08R14.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoh
15、ocken, PA 19428-2959. United States17. Calculation7.1 Calculate the SiO2concentration in the concentratestream from the SiO2concentration in the feed solution, therecovery of the reverse osmosis system, and the SiO2passageas follows:SiO2c5 SiO2f31 2 YSPSiO2!1 2 Ywhere:SiO2c= silica concentration in
16、concentrate as SiO2, mg/L,SiO2f= silica concentration in feed as SiO2, mg/L,Y = recovery of the reverse osmosis system, expressedas a decimal, andSPSiO2= silica passage, expressed as a decimal.NOTE 3SPSiO2can be obtained from the supplier of the reverseosmosis system.7.2 Calculate the pH of the conc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD499320082014STANDARDPRACTICEFORCALCULATIONANDADJUSTMENTOFSILICA40SIO241SCALINGFORREVERSEOSMOSIS

链接地址:http://www.mydoc123.com/p-518605.html