ASTM D4940-2015e1 Standard Test Method for Conductimetric Analysis of Water Soluble Ionic Contamination of Blast Cleaning Abrasives《喷砂磨料水溶解离子污染导电分析的标准试验方法》.pdf
《ASTM D4940-2015e1 Standard Test Method for Conductimetric Analysis of Water Soluble Ionic Contamination of Blast Cleaning Abrasives《喷砂磨料水溶解离子污染导电分析的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4940-2015e1 Standard Test Method for Conductimetric Analysis of Water Soluble Ionic Contamination of Blast Cleaning Abrasives《喷砂磨料水溶解离子污染导电分析的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4940 151Standard Test Method forConductimetric Analysis of Water Soluble IonicContamination of Blast Cleaning Abrasives1This standard is issued under the fixed designation D4940; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEConversion factor in Note 1 was editorially corrected in July 2016.1. Scope1.1 This test method describ
3、es a procedure for assessingblast cleaning abrasives for the presence of conductive-potential, ionic contaminants by determining the total concen-tration of water soluble conductive species using a conductivitytest.1.2 This test method does not identify the ionic speciespresent nor provide quantitat
4、ive results on each species.1.3 This test method is based on a volume comparisonamong abrasives of similar sizes. A volume comparison ismore closely related to surface area of the abrasives than is aweight comparison.1.4 The values stated in SI units are to be regarded asstandard. No other units of
5、measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory
6、 limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterE832 Specification for Laboratory Filter Papers2.2 Other Standard:ISO 11127-6 Preparation of Steel Substrates beforeApplica-tion of Paints and Related Products - Test Methods forNon-Metallic Bla
7、st Cleaning Abrasives - Part 6: Determi-nation of Water-Soluble Contaminants by ConductivityMeasurement32.3 SSPC: The Society for Protective Coatings:4SSPC-AB 1 Mineral and Slag AbrasivesSSPC-AB 2 Cleanliness of Recycled Ferrous Metallic Abra-siveSSPC-AB 3 Ferrous Metallic AbrasiveSSPC-AB 4 Recyclab
8、le Encapsulated Abrasive Media3. Summary of Test Method3.1 Abrasive and pure water are combined into a slurry thatis stirred to leach the soluble salts from the abrasive. Thisslurry is filtered and conductance of the filtrate is measured.The conductivity, which is related to the concentration ofsolu
9、ble ionic materials contaminating the abrasive, is calcu-lated from the conductance and the cell constant.4. Significance and Use4.1 Abrasive media may contain ionic contamination natu-rally (for example, beach sand), from manufacturing (quench-ing with contaminated water), transportation, storage o
10、r use (inthe case of abrasive that is reused). Ionic contamination on theabrasive may transfer to the surface during abrasive blastcleaning, resulting in potential osmotic blistering, acceleratedunderfilm corrosion and premature coating failure.4.2 This test method describes a shop/field procedure f
11、orassessing the level of conductive species on an abrasive.4.3 Abrasive standards published by SSPC (AB) and ISO11126 provide tolerance levels for water soluble contaminantsof the abrasive.5. Apparatus5.1 Conductivity Bridge and CellAny commercial con-ductivity bridge and conductivity cell typically
12、 having a rangeof at least 5 mho/cm to 10,000 mho/cm with built-in1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, andApplications and is the direct responsibility ofSubcommittee D01.46 on Industrial Protective Coatings.Current edition approv
13、ed Dec. 1, 2015. Published December 2015. Originallyapproved in 1989. Last previous edition approved in 2010 as D4940 10. DOI:10.1520/D4940-15E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards
14、 volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from Society for Protective Coatings (SSPC), 40 24th St., 6th Floor,Pittsburg
15、h, PA 15222-4656, http:/www.sspc.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1temperature compensation is satisfactory. A dip-type, pipet-type, or cup-type cell may be used.5.2 Filter Paper, conforming to Specification E832, Ty
16、pe 1,Class C, to keep silt from fouling the surfaces of the conduc-tivity cell.NOTE 1ISO 11127-6 is another method for assessing the level ofsoluble salt contamination present in an abrasive. It differs from this testmethod in two major areas:(1) The ISO method uses a weight to volume ratio between
17、the abrasiveand the fluid (deionized water) used to extract soluble salts from theabrasive. The ASTM method allows a user to measure a loose packedvolume of abrasive and mix that abrasive with an equal volume of reagentwater. The ISO method is well suited to use in a laboratory setting but ispoorly
18、suited to use in the field. The ASTM method is well suited for usein the field or laboratory.(2) The ISO method reports the effect of the level of extracted salts interms of milliSiemens/m, whereas this test method uses mho/cm. TheISO method uses strict SI units, this test method reports using SIcom
19、pliant units.Method to Method Comparison:The reader is warned that it is difficult to make direct comparisonsbetween the results of these two different methods of analysis.Weight/Volume versus Volume/Volume Method Considerations:In the ASTM Method the weight of the abrasive is not known; thismakes i
20、t impossible to assess the ratio between conductivity valuesdetermined using this test method procedure and those determined usingthe ISO 11127-6 procedure.Comparisons Between Reported Units for Each Method:An independent study by SSPC showed that the relative order ofextracted salts using each type
21、 of procedure on abrasive materials wasidentical. The ranked order correlation between the two methods wasunity. There was no direct correlation possible between numerical resultsobtained and reported by the two different methods. Abrasives thatshowed qualifying extracted salts using the ISO Procedu
22、re also showedqualifying extracted salt levels as specified in SSPC-AB 1.Converting from ISO Reported Units to ASTM Reported Units:Converting from one unit base to another is not useful as the twomethods differ in process. The conversion factor from mho/cm tomilliSiemens/m is as follows:A Micro Mho
23、Per Centimeter1mhocm1=(1106) 1cm1A MilliSiemen Per Meter1 (MilliSiemen)(m1)=(1103) 1(1102)cm1Thus one milliSiemen/m = ten mho/cm.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to th
24、e specifications of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications are available.5Other grades may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determinati
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD49402015E1STANDARDTESTMETHODFORCONDUCTIMETRICANALYSISOFWATERSOLUBLEIONICCONTAMINATIONOFBLASTCLEANINGABRASIVES

链接地址:http://www.mydoc123.com/p-518457.html