ASTM D4880-2008 Standard Test Method for Salt Water Proofness of Insulating Varnishes Over Enamelled Magnet Wire《漆包磁线上绝缘清漆防盐水腐蚀的标准试验方法》.pdf
《ASTM D4880-2008 Standard Test Method for Salt Water Proofness of Insulating Varnishes Over Enamelled Magnet Wire《漆包磁线上绝缘清漆防盐水腐蚀的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4880-2008 Standard Test Method for Salt Water Proofness of Insulating Varnishes Over Enamelled Magnet Wire《漆包磁线上绝缘清漆防盐水腐蚀的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4880 08An American National StandardStandard Test Method forSalt Water Proofness of Insulating Varnishes OverEnamelled Magnet Wire1This standard is issued under the fixed designation D 4880; the number immediately following the designation indicates the year oforiginal adoption or, in
2、 the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the performance in a specifiedwater solution of an insulat
3、ing varnish applied over enamelledmagnet wire.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.3 This standard does not purport to
4、 address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Sec
5、tion 6.NOTE 1There is no IEC method equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2D 1676 Test Methods for Film-Insulated Magnet WireD 1711 Terminology Relating to Electrical Insulation3. Terminology3.1 Definitions: For definitions of terms used in this testmethod refer to Te
6、rminology D 1711.3.1.1 varnish, electrical insulating, n a liquid resin sys-tem that is applied to and cured on electrical componentsproviding electrical, mechanical, and environmental protec-tion.3.1.1.1 DiscussionThere are two types of electrical insu-lating varnish solventcontaining and solventle
7、ss. Thesolvent-containing varnish is solution, dispersion, or emulsionof a polymer or a mixture of polymers in a volatile, nonre-actable liquid. The solventless type is a liquid resin system freeof volatile, nonreactable solvents.3.1.2 varnished, adjreferring to any item on to whichvarnish has been
8、applied and cured.4. Significance and Use4.1 This test method is useful in determining the perfor-mance of varnishes over enamelled magnet wire when sub-jected to the specified sodium chloride solution. It is useful inevaluating the resistance of varnished magnet wire to a dilutedsodium chloride sol
9、ution under applied voltage.5. Apparatus5.1 Description of Electrical Apparatus:5.1.1 The apparatus shall contain devices for limiting orinterrupting the current to each specimen whenever a failureoccurs. In particular, 7.5 W light bulbs or110 Afuses have beenused. Lighting of the bulb or “blowing”
10、of the fuse indicatesfailure.5.1.2 The power supply shall provide a source of filtered120 6 2 V dc which drops by less than 2 V when a current of0.5 A is drawn.5.1.3 A positive polarity of 120 V dc is applied to thespecimens. The surrounding sodium chloride solution is atground potential. The ground
11、 connection, using an immersedelectrode, is made using Nichrome, stainless steel, or othernon-corrosive wire. Do not use iron, carbon steel, copper, orbrass (see Fig. 1).5.2 An appropriate container shall be selected for thesodium chloride solution. Fit it with a cover to preventevaporation of the s
12、olution.6. Safety Precautions6.1 Do not use varnish at temperatures above the flash pointwhen inadequate ventilation, and possibility of flames orsparks exist. Store varnish in sealed containers. These precau-tions shall also apply to the handling of the reagents andsolvents called for in this test
13、method.6.2 WarningLethal voltages are a potential hazard duringthe performance of this test. It is essential that the testapparatus, and all associated equipment electrically connectedto it, be properly designed and installed for safe operation.1This test method is under the jurisdiction of ASTM Com
14、mittee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.01 on Electrical Insulating Varnishes, Powders and Encapsulat-ing Compounds.Current edition approved May 1, 2008. Published June 2008. Originallyapproved in 1988. Last previous edition app
15、roved in 2003 as D 4880 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section app
16、ears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Solidly ground all electrically conductive parts which it ispossible for a person to contact during the test. Provide meansfor use at the completion of a
17、ny test to ground any parts whichwere at high voltage during the test or have the potential foracquiring an induced charge during the test or retaining acharge even after disconnection of the voltage source. Thor-oughly instruct all operators as to the correct procedures forperforming tests safely.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD48802008STANDARDTESTMETHODFORSALTWATERPROOFNESSOFINSULATINGVARNISHESOVERENAMELLEDMAGNETWIRE 漆包磁

链接地址:http://www.mydoc123.com/p-518295.html