ASTM D4821-2007e1 Standard Guide for Carbon BlackValidation of Test Method Precision and Bias《炭黑标准指南 试验方法精度和偏差的验证》.pdf
《ASTM D4821-2007e1 Standard Guide for Carbon BlackValidation of Test Method Precision and Bias《炭黑标准指南 试验方法精度和偏差的验证》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4821-2007e1 Standard Guide for Carbon BlackValidation of Test Method Precision and Bias《炭黑标准指南 试验方法精度和偏差的验证》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4821 071Standard Guide forCarbon BlackValidation of Test Method Precision andBias1This standard is issued under the fixed designation D4821; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorially corrected Footnote 3 and corresponding references in August 2011.1. Scope1.1 This guide covers a procedure for usingASTM Standard
3、Reference Blacks2(SRBs) to continuously monitor the preci-sion of those carbon black test methods for which standardvalues have been established. It also offers guidelines fortroubleshooting various test methods.1.2 This guide establishes the x-chart control limits to beused when continuously monito
4、ring those tests listed in Section2. Alternatively, these control limits may be used as a basis forcomparison to testing precision computed within a laboratory.1.3 This guide uses statistical control chart methodology asdiscussed in MNL73to determine if a laboratorys test resultsdiffer significantly
5、 from the accepted values of the SRBs.1.4 This guide provides a statistical procedure for improv-ing test reproducibility when a laboratory cannot physicallycalibrate its apparatus to obtain the standard values of theASTM SRBs, within the ranges given in the precision state-ment of the test method.1
6、.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appr
7、o-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:4D1510 Test Method for Carbon BlackIodine AdsorptionNumberD1513 Test Method for Carbon Black, PelletedPour Den-sityD1765 Classification System for Ca
8、rbon Blacks Used inRubber ProductsD2414 Test Method for Carbon BlackOil AbsorptionNumber (OAN)D3037 Test Methods for Carbon Black-Surface Area byNitrogen Adsorption5D3191 Test Methods for Carbon Black in SBR (Styrene-Butadiene Rubber)Recipe and Evaluation ProceduresD3192 Test Methods for Carbon Blac
9、k Evaluation in NR(Natural Rubber)D3265 Test Method for Carbon BlackTint StrengthD3493 Test Method for Carbon BlackOil AbsorptionNumber of Compressed Sample (COAN)D3765 Test Method for Carbon BlackCTAB (Cetyltrim-ethylammonium Bromide) Surface Area5D4820 Standard Test Methods for Carbon Black-Surfac
10、eArea by Multipoint B.E.T. Nitrogen Adsorption5D5816 Standard Test Methods for Carbon Black-ExternalSurface Area by Multipoint Nitrogen Adsorption5D6556 Test Method for Carbon BlackTotal and ExternalSurface Area by Nitrogen Adsorption3. Significance and Use3.1 One of the major causes of poor test pr
11、ecision is the lackof calibration or standardization of instruments, apparatus,reagents, and technique among laboratories. The sum of allsources of testing error is unique for an individual laboratory.1This guide is under the jurisdiction ofASTM Committee D24 on Carbon Blackand is the direct respons
12、ibility of Subcommittee D24.61 on Carbon Black Samplingand Statistical Analysis.Current edition approved Oct. 1, 2007. Published November 2007. Originallyapproved in 1988. Last previous edition approved in 2006 as D4821 06. DOI:10.1520/D4821-07E01.2Standard Reference Blacks are available from Labora
13、tory Standards notto all the tests in Table 1 or Table 2.5.10 When it becomes necessary to use a statistical correc-tion factor, all the SRBs for the range of interest (A-F or A-G)must be used to develop the linear regression equation, even ifsome of the SRBs fall outside the range of interest. At l
14、eastfour values (six preferred) should be used for each SRB. Anequal number of results must be used for each SRB. If theseinstructions are not followed, the correction equation will notbe comparable to the corrections made for other instrumentsand other laboratories. For the oil absorption test (Tes
15、t MethodD2414), it is acceptable to develop a separate linear regressionequation for the tread (A-C) and carcass (D-F) SRBs.5.11 Continuously monitor the selected SRBs and use themost current data to construct the correction equation.5.12 Use the correction equation to obtain corrected valuesfor the
16、 SRBs and plot the corrected values until the controllimit is exceeded. When a test value exceeds the control limit,perform a retest immediately, and if the average of the tworemains outside the control limit, then recalculate the statisticalcorrection equation using the most recent test data, exclu
17、dingthe value that was outside the control limit, for each selectedSRB.5.13 If the corrected data using the new correction equationstill fall outside the control limits, then no further use should bemade of the test method until corrective action (see Section 6)brings the SRBs back inside the three
18、standard deviationcontrol chart limits.5.14 Apply this procedure only to the interpretation of SRBtest data. If problems exist, correct them before making furtheruse of the test method. “Local reference” materials do not haveestablished “industry average” values to be used in a linearregression equa
19、tion.5.15 This procedure prescribes only the minimum actionneeded to continuously monitor test precision.Additional SRBtesting may be done and correction equations regularly recal-culated at individual discretion.5.16 Discontinue using a statistical correction equationwhen new or repaired test equip
20、ment is put into service, a newlot of SRBs are purchased and put into use, or other correctiveactions yield uncorrected test results that fall within the controllimits. Resume using a statistical correction equation onlywhen the conditions of Section 4 and 5.1 have again beensatisfied.6. Assignable
21、Causes6.1 The following lists suggest several assignable causes aspossible reasons for a test to be out of statistical control.6.1.1 Test Method D1510 Iodine Adsorption Number:6.1.1.1 Incorrect normality of iodine and sodium thiosulfatesolutions,6.1.1.2 Volumetric glassware not calibrated correctly,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD48212007E1STANDARDGUIDEFORCARBONBLACKVALIDATIONOFTESTMETHODPRECISIONANDBIAS 炭黑 标准 指南 试验 方法 精度 偏差

链接地址:http://www.mydoc123.com/p-518123.html