ASTM D4789-2003 Standard Test Method for Solution Color of Bisphenol A (4 4&180-Isopropylidenediphenol)《(4 4-二酚基丙烷)双酚A溶液颜色的标准试验方法》.pdf
《ASTM D4789-2003 Standard Test Method for Solution Color of Bisphenol A (4 4&180-Isopropylidenediphenol)《(4 4-二酚基丙烷)双酚A溶液颜色的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4789-2003 Standard Test Method for Solution Color of Bisphenol A (4 4&180-Isopropylidenediphenol)《(4 4-二酚基丙烷)双酚A溶液颜色的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4789 03Standard Test Method forSolution Color of Bisphenol A (4,4*-Isopropylidenediphenol)1This standard is issued under the fixed designation D 4789; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the procedure for determina-tion of the Platinum-Cobalt Color of 4,48-Isopropylidenediphenol, c
3、ommercially known as bisphenol A,dissolved in methanol.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility
4、 of regulatory limitations prior to use. For a specifichazard statement, see Section 8.2. Referenced Documents2.1 ASTM Standards:D 1209 Test Method for Color of Clear Liquids (Platinum-Cobalt Scale)2D 4297 Practice for Sampling and Handling 4,48-Isopropylidenediphenol (Bisphenol A)2E 180 Practice fo
5、r Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals32.2 Other Documents:OSHA Regulations, 29 CFR, paragraphs 1910.1000 and1910.12004NIST Letter Circular LC 1017, Standard for Checking theCalibration of Spectrophotometers (200 to 1000 nm)53. Summ
6、ary of Test Method3.1 Bisphenol A is dissolved in methanol. This solution isthen transferred to a color comparison tube and the colorcompared to that of the Platinum-Cobalt Color Standards,either visually or by means of a spectrophotometer. The coloris reported as that closest to the applicable stan
7、dard.4. Significance and Use4.1 Color is caused by impurities in the bisphenol A. Theacceptable amount of color depends on the end-use of thebisphenol A.4.2 This test method can be used for internal quality controlor for setting specifications.5. Interferences5.1 The presence of any turbidity or haz
8、e will affect thecolor reading.5.2 A bisphenol A color that is off-hue, or tinted with respectto the color standards, may interfere with proper color com-parison.6. Apparatus6.1 Color Comparison TubesMatched 100 mL, tall-formNessler tubes, provided with ground-on, optically clear, glasscaps. Tubes s
9、hould be selected so that the height of the 100-mLgraduation mark is 275 to 295 mm above the bottom of thetube.6.2 Color Comparator, constructed to permit visual com-parison of light transmitted through tall-form, 100 mL Nesslertubes in the direction of their longitudinal axis; and so thatwhite ligh
10、t is passed through or reflected off a white glass plateand directed with equal intensity through the tubes. It should beshielded so that no light enters the tubes from the sides.6.3 Spectrophotometer, equipped for liquid samples and formeasurements in the visible region.NOTE 1The spectrophotometer
11、must be clean and in excellent oper-ating condition. The instrument should be calibrated in accordance withthe instructions given in NIST Letter Circular LC 1017. For goodagreement with the visual method, the spectrophotometer or colorimetershould be a filter type instrument.6.4 Spectrophotometer Ce
12、lls, cells of different path lengthsmay be used as long as the equipment is calibrated with thesame length cells as the sample solution.6.5 Filter Paper, glass fiber filter, 1.2-m pore retention.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indi
13、cated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubc
14、ommittee D16.02 on Oxygenated Aromatics.Current edition approved Jan. 10, 2003. Published March 2003. Originallyapproved in 1988. Last previous edition approved in 1994 as D 4789 94.2Annual Book of ASTM Standards, Vol 06.04.3Annual Book of ASTM Standards, Vol 15.05.4Available from U.S. Government Pr
15、inting Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401.5Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 3460, Gaithersburg, MD 20899-3460.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
16、Conshohocken, PA 19428-2959, United States.where such specifications are available.6Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.7.2 MethanolCheck for color against deioni
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便