ASTM D4754-2011 Standard Test Method for Two-Sided Liquid Extraction of Plastic Materials Using FDA Migration Cell《使用液膜蒸馏器(FDA)移动元件进行塑料制品的双侧液体提取的标准试验方法》.pdf
《ASTM D4754-2011 Standard Test Method for Two-Sided Liquid Extraction of Plastic Materials Using FDA Migration Cell《使用液膜蒸馏器(FDA)移动元件进行塑料制品的双侧液体提取的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4754-2011 Standard Test Method for Two-Sided Liquid Extraction of Plastic Materials Using FDA Migration Cell《使用液膜蒸馏器(FDA)移动元件进行塑料制品的双侧液体提取的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4754 11Standard Test Method forTwo-Sided Liquid Extraction of Plastic Materials Using FDAMigration Cell1This standard is issued under the fixed designation D4754; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the use of the FDA migrationcell in the extraction of components and permits quantitati
3、on ofindividual migrants from plastic materials by suitable extract-ing liquids, including liquid foods and food-stimulating sol-vents.1.2 This test method provides a two-sided, liquid extractiontest for plastic materials that can be formed into film, sheet, ordisks.1.3 This test method has been app
4、lied to a variety ofmigrant/polymer systems in contact with numerous foods andfood simulants.2Though most of the migrants examined wereradiolabeled, the use of the FDA cell has been validated formigration studies of unlabeled sytrene from polystyrene.31.4 This test method has been shown to yield rep
5、roducibleresults under the conditions for migration tests requested by theFDA. However, if the data is to be submitted to the FDA, it issuggested that their guidelines be consulted.1.5 Because it employs two-sided extraction, this testmethod may not be suitable for multi-layered plastics intendedfor
6、 single-sided food contact use.1.6 The size of the FDA migration cell as described maypreclude its use in determining total nonvolatile extractives insome cases.NOTE 1For more information, see Practice D1898, the AOAC Meth-ods of Analysis on Flexible Barrier Materials Exposed for Extraction, andthe
7、Guidance for Industry: Preparation of Premarket Submissions for FoodContact Substances: Chemistry Recommendations, December 2007.1.7 Analytical procedures must be available to quantitatethe migrant(s) generated by this test method.1.8 The values stated in SI units are to be regarded as thestandard.1
8、.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazard
9、sstatements are given in Section 8.NOTE 2There is no known ISO equivalent to this test method.2. Referenced Documents2.1 ASTM Standards:4D883 Terminology Relating to PlasticsD1898 Practice for Sampling of Plastics5E691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a T
10、est MethodIEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI): The Modernized Metric System2.2 Association of Offcial Analytical Chemists (AOAC)Methods of Analysis:Flexible Barrier Materials Exposed for Extraction62.3 Federal Document:Guidance for Industry: Preparation of Prema
11、rket Submis-sions for Food Contact Substances: Chemistry Recom-mendations, December 200773. Terminology3.1 GeneralThe units, symbols, and abbreviations used inthis test method are in accordance with Terminology D883 andPractice IEEE/ASTM SI 10.4. Summary of Test Method4.1 Specimens of plastic materi
12、als, formed in the shape ofdisks, are threaded onto a stainless steel wire with alternatingglass bead spacers and placed in a glass vial. Solvent is addedto the vial and the vial is capped and maintained at the desiredextraction temperature. Aliquots of the liquid are removed at1This test method is
13、under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.70 on Analytical Methods.Current edition approved Dec. 1, 2011. Published December 2011. Originallyapproved in 1987. Last previous edition approved in 2003 as D4754 98(2003).DOI: 10.1520/D475
14、4-11.2“A Study of Indirect Food Additive Migration,” Arthur D. Little, Inc., FDAContract No. 223-77-2360.3Supporting data have been filed at ASTM International Headquarters and maybe obtained by requesting Research Report RR:D20-1141.4For referenced ASTM standards, visit the ASTM website, www.astm.o
15、rg, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.5Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.6Available through the Associati
16、on of Official Analytical Chemists, 481 NorthFrederick Avenue, Suite 500, Gaithersburg, Maryland 20877-2417 USA.7Available from Division of Food Contact Notifications, Office of FoodAdditiveSafety, Center for Food Safety and Applied Nutrition, Food and Drug Administra-tion, College Park, MD 20740, U
17、SA.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.various times and the migrant(s) in the liquid determined bysuitable analytical methods.NOTE 3 Significant migration
18、 loss due to volatility may occur ifmigration is carried out at temperatures exceeding 50C for periodsgreater than 2 weeks.5. Significance and Use5.1 Knowledge of migrants from plastic materials mayserve many useful purposes, such as testing for compliancewith food additive regulations. The procedur
19、e described in thistest method is recommended as suitable for obtaining such dataon many migrant(s)/plastic(s) combinations.6. Apparatus6.1 FDA Migration Cell8(Fig. 1), consisting of:6.1.1 Glass Vials, 23-mL,6.1.2 Mininertt Slide Valve Caps,6.1.3 Stainless Steel Wire (20-gage), and6.1.4 Glass Bead (
20、5-mm diameter), containing hole slightlylarger than diameter of stainless steel wire.9(Available at localhobby shops.)NOTE 4The apparatus, disk size, and number of disks are describedfor the 23-mL vial. Alternative vial sizes and corresponding test specimensizes may be substituted. (The volume-to-su
21、rface area ideally should bebetween 155 and 0.31 mL/cm2.) Note that validation tests have only beenconducted using the 23-mL vials.NOTE 5Recommend one-time use of mininert valve (that is, discard-ing it at completion of study).6.2 Hot-Air Oven or Static Thermostatted Water Bath, withsuitable safety
22、provisions and capable of maintaining thedesired extraction temperature within 61C.6.3 Thermostatted Shaker Water Bath8,10Some migrant/plastic/liquid combinations may involve significant partition-ing and would benefit by having the cells shaken throughoutthe migration study.6.4 Liquid Syringes, for
23、 removing liquid aliquots from thecells and transferring them to the analytical instrumentation.6.5 Analytical Instrumentation, as required by the methodchosen to determine the migrant(s).7. Reagents and Materials7.1 Purity of ReagentsAll solvents shall be HPLC orchromatographic grade and shown to b
24、e free of interferences inthe detection region of the migrant(s).8. Hazards8.1 The usual safety precautions for handling flammablesolvents are recommended when such solvents are used forextraction.9. Sampling9.1 Sample the plastic in accordance with Practice D1898.9.2 Select representative samples o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD47542011STANDARDTESTMETHODFORTWOSIDEDLIQUIDEXTRACTIONOFPLASTICMATERIALSUSINGFDAMIGRATIONCELL 使用
链接地址:http://www.mydoc123.com/p-517896.html