《ASTM D4747-2002 Standard Test Method for Determining Unreacted Monomer Content of Latexes Using Gas-Liquid Chromatography《用气液色谱法测定乳胶中未反应单体含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4747-2002 Standard Test Method for Determining Unreacted Monomer Content of Latexes Using Gas-Liquid Chromatography《用气液色谱法测定乳胶中未反应单体含量的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4747 02Standard Test Method forDetermining Unreacted Monomer Content of Latexes UsingGas-Liquid Chromatography1This standard is issued under the fixed designation D 4747; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of freemonomer content of acrylic latexes. Monomers that hav
3、e beensuccessfully determined by this procedure include n-butylmethacrylate, n-butyl acrylate, styrene, and methyl methacry-late. The determination of other monomers has not beenevaluated, but this test method is believed to be applicable. Theestablished working range of this test method is from 100
4、 to1000 g/g, but there is no reason to believe it will not workoutside of this range, provided that appropriate dilutions andadjustments in specimen size are made.1.2 The volatile composition of acrylic latexes is expectedto change with time and environmental factors. This timedependence of the dete
5、rmination may be seen as an artificiallylarge deviation of results, making the method mostly appli-cable for in-house quality control, where sampling and analysisconditions can be better controlled.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in paren
6、theses are forinformation only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitatio
7、ns prior to use. See Section 7 forspecific hazard statements.2. Referenced Documents2.1 ASTM Standards:D 3980 Practice for Interlaboratory Testing of Paint andRelated Materials2E 260 Practice for Packed Column Gas Chromatography33. Summary of Test Method3.1 A suitable aliquot of the latex is interna
8、lly standardizedwith isobutyl acrylate, diluted with water, and then injectedinto a gas chromatographic column containing a packingmaterial coated with a stationary phase that separates theinternal standard and monomers in question from each otherand from other volatile compounds.4. Significance and
9、 Use4.1 Excessive amounts of unreacted monomer may causeconcerns relating to toxicity and odor. This test method isdesigned to measure the unreacted monomer content of latexes.The results may be used to monitor the extent of polymeriza-tion during manufacture, as well as to establish maximumunreacte
10、d monomer content for regulatory purposes.5. Apparatus5.1 Gas Chromatograph, any gas-liquid chromatographicinstrument having a flame ionization detector and lineartemperature programming. An injection port using replacableglass liners to facilitate periodic removal of accumulatedresidues is recommen
11、ded.5.2 Column, 2 by 2-mm inside diameter glass or 6 ft by18-in. outside diameter steel tubing, packed with 10 % byweight of a 2-nitroterephthalic acid derivative of a syntheticpolyester wax on 100/120 mesh acid washed, silane treateddiatomaceous earth.4A column of equivalent or superiorperformance
12、may also be used.5.3 RecorderA recording potentiometer with a full-scaledeflection of 10 mV, a full-scale response time of2sorless,and a maximum noise level of 60.03 % of full scale (seePractice E 260).5.4 Liquid Charging Devices, microsyringe, 10-L capacityor an automatic liquid sampling device.5.5
13、 Dropper Pipets, glass, disposable.5.6 Vials, approximately 7-mL capacity, with caps. Open topscrew cap vials fitted with polytetrafluoroethylene/siliconesepta are preferred.5.7 Autosampler Vials, 2-mL capacity (optional).5.8 Analytical Balance, accurate to 0.1 mg.6. Reagents6.1 Purity of ReagentsRe
14、agent grade chemicals shall be1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved Jan. 10, 2002.
15、Published March 2002.Originallypublished as D 4747 - 87. Last previous edition D 4747 - 87 (1996)1.2DiscontinuedSee1999 Annual Book of ASTM Standards.3Annual Book of ASTM Standards, Vol 03.06.4Columns prepared from the stationary phases and supports have been foundsuitable for this purpose and are a
16、vailable from scientific supply houses.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.used in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical
17、 Reagents of the American Chemical Society,where such specifications are available.5Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Carrier Gas, helium of 99.995 % or hig
18、her purity. Highpurity nitrogen may also be used.6.3 Acetone, reagent grade.6.4 Isobutyl Acrylate (internal standard), 99+ % pure.NOTE 1Isobutyl acrylate was found to be a suitable internal standard,but any other monomer not found in the sample may be substituted. Theinternal standard chosen should
19、yield a clear chromatographic separation,and should be free of interferences.6.5 Monomers of Interest, 99+ % pure.7. Hazards7.1 Acrylic and methacrylic monomers are considered haz-ardous. Precautions should be taken to avoid inhalation andskin or eye contact with these chemicals. All sample prepara-
20、tions should be done in a well-ventilated area, such as a fumehood.8. Preparation of Apparatus8.1 Column ConditioningAttach one end of the column tothe inlet side of the instrument leaving the exit end of thecolumn disconnected. This prevents the contamination of thedetector due to column bleed. Set
21、 the helium flow rate at 30mL/min and purge the column at ambient temperature for 30min. Program the column oven from 50 to 220C at 2C/minand maintain at 220C overnight. In no case should thetemperature of the column be allowed to exceed 275C.8.2 After conditioning, connect the exit end of the colum
22、n tothe detector and establish the operating conditions required togive the desired separation (see Table 1). Allow sufficient timefor the instrument to reach equilibrium as indicated by a stablebaseline. Control the detector temperature so that it is constantto within 1C without thermostat cycling
23、which causes anuneven baseline. Adjust the carrier gas flow rate to a constantvalue.9. Calibration9.1 Determine the retention of each component expected tobe present by injecting small amounts either separately or inknown mixtures. Retention times should be determined eachday the method is used.9.2
24、StandardizationDetermine in duplicate the relativeresponse of the monomers of interest to the isobutyl acrylateinternal standard as follows:9.2.1 Weigh to 0.1 mg about 0.05 g of isobutyl acrylate andeach monomer of interest into a vial (5.6). Weigh approxi-mately5gofacetone into the vial and mix wel
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD47472002STANDARDTESTMETHODFORDETERMININGUNREACTEDMONOMERCONTENTOFLATEXESUSINGGASLIQUIDCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-517879.html