《ASTM D3681-2012e1 Standard Test Method for Chemical Resistance of “Fiberglass” (Glass–Fiber–Reinforced Thermosetting-Resin) Pipe in a Deflected Condition.pdf》由会员分享,可在线阅读,更多相关《ASTM D3681-2012e1 Standard Test Method for Chemical Resistance of “Fiberglass” (Glass–Fiber–Reinforced Thermosetting-Resin) Pipe in a Deflected Condition.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3681 121An American National StandardStandard Test Method forChemical Resistance of “Fiberglass”(GlassFiberReinforced Thermosetting-Resin) Pipe in aDeflected Condition1This standard is issued under the fixed designation D3681; the number immediately following the designation indicates
2、the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorially corrected Table A1.2 in March 2014.1. Scope
3、*1.1 This test method covers the procedure for determiningthe chemical-resistant properties of fiberglass pipe in a de-flected condition for diameters 4 in. (102 mm) and larger. Bothglassfiberreinforced thermosetting resin pipe (RTRP) andglassfiberreinforced polymer mortar pipe (RPMP) are fiber-glas
4、s pipes.NOTE 1For the purposes for this standard, polymer does not includenatural polymers.1.2 Inch-pound units are to be regarded as the standard. Thevalues given in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with
5、 its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in 9.5.NOTE 2There is no known ISO equivalent to this standard.2.
6、 Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD3567 Practice for Determining Dimensions of “Fiberglass”(Glass-Fiber-Reinforced Thermosetting Resin) Pipe andFittings2.2 ISO Standard:3 Preferred NumbersSeries o
7、f Preferred Numbers33. Terminology3.1 Definitions:3.1.1 GeneralDefinitions are in accordance with Termi-nology D883 and abbreviations are in accordance with Termi-nology D1600 unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 end pointthe passage of the fluid throug
8、h the pipewall unless otherwise stated. The failure mode may becatastrophic, characterized by a sudden fracture through thepipe wall in the area of greatest strain, parallel to the axis of thepipe, with the fiber reinforcement cleanly broken at the edge ofthe fracture. Visual evidence of surface etc
9、hing or pitting mayor may not be present.3.2.2 fiberglass pipetubular product containing glass fiberreinforcements embedded in or surrounded by cured thermo-setting resin. The composite structure may contain aggregate,granular or platelet fillers, thixotropic agents, pigments, ordyes. Thermoplastic
10、or thermosetting liners or coatings may beincluded.3.2.3 reinforced polymer mortar pipe (RPMP)fiberglasspipe with aggregate.3.2.4 reinforced thermosetting resin pipe (RTRP)fiberglass pipe without aggregate.3.2.5 strain-corrosionthe failure of the pipe wall causedby the exposure of the inside surface
11、, while in a strainedcondition, to a corrosive environment for a period of time.4. Summary of Test Method4.1 This test method consists of exposing the interior of aminimum of 18 specimens of pipe to a corrosive test solutionwhile the pipe is constantly maintained in a deflected conditionat differing
12、 induced initial ring flexural strain levels, and1This test method is under the jurisdiction ofASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.23 on Reinforced PlasticPiping Systems and Chemical Equipment.Current edition approved April 1, 2012. Published May 2012.
13、Originallyapproved in 1978. Last previous edition approved in 2006 as D3681 06. DOI:10.1520/D3681-12E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standard
14、s Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700,
15、 West Conshohocken, PA 19428-2959. United States1measuring the time to failure for each strain level. Testtemperatures are obtained by testing in an air environmentwhere the temperature is controlled.4.2 The long-term resistance of the pipe to the test solutionis obtained by an extrapolation to 50 y
16、ears of a log-log linearregression line for initial strain level versus time.NOTE 3It is the consensus of Subcommittee D20.23 that the logloglinear regression analysis of test data is a conservative approach and isrepresentative of standard industry practice. However, a task group hasbeen formed to
17、evaluate alternative non-linear analysis methods.5. Significance and Use5.1 This test method evaluates the effect of a chemicalenvironment on pipe when in a deflected condition. It has beenfound that effects of chemical environments can be acceleratedby strain induced by deflection. This information
18、 is useful andnecessary for the design and application of buried fiberglasspipe.NOTE 4Pipe of the same diameter but of different wall thicknesseswill develop different strains with the same deflection. Also, pipes havingthe same wall thickness but different constructions making up the wallmay develo
19、p different strains with the same deflection.6. Apparatus6.1 Use parallel plate apparatus suitable to maintain aconstant deflection on the pipe. In order to achieve uniformstrain along the pipe, use 0.25-in. (6-mm) thick elastomericpads between the parallel plate (channel) surfaces and the pipering
20、(see Note 5). Foil type, single element strain gages suitablefor strain levels to 1.50 % strain and a length appropriate to thediameter of the pipe are required when initial strain is to bedetermined by Procedure B (see Note 6). An example of theapparatus required is shown in Fig. 1.NOTE 5Elastomeri
21、c pads with a hardness of Shore A15 to 70 havebeen used successfully.NOTE 6Strain gages of14 and12-in. (6 and 13-mm) length have beenfound to be effective for pipe diameters 12 through 24 in. (305 through610 mm). Consult the strain gage manufacturer for gage length recom-mendations for other pipe di
22、ameters.7. Test Specimens7.1 The test specimens shall be ring sections taken from asample of pipe selected at random from a normal productionrun. The test specimens shall have a minimum length of onenominal pipe diameter or 12 in. (300 mm) 6 5 %, whicheveris less.8. Test Conditions8.1 The standard t
23、emperature shall be 73.4 6 3.6F (23 62C).9. Procedure9.1 GeneralDetermine the initial strain level induced inthe pipe by calculation, or strain gage measurement, or both.Procedure A describes the determination of initial strain bycalculation; Procedure B describes the determination of initialstrain
24、as obtained by use of foil-type resistance strain gages.9.2 Determination of Test Level:9.2.1 Test Procedure A:9.2.1.1 In accordance with Practice D3567 measure the wallthickness to the nearest 0.001 in. (0.025 mm) in at least fiveequally spaced places along the bottom of the pipe specimen ona line
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD36812012E1STANDARDTESTMETHODFORCHEMICALRESISTANCEOF FIBERGLASS GLASS FIBER REINFORCEDTHERMOSETTINGRESINPIPEINADEFLECTEDCONDITIONPDF

链接地址:http://www.mydoc123.com/p-517692.html