ASTM D4640-1986(2009) Standard Test Method for Determining Stroke Cure Time of Thermosetting Phenol-Formaldehyde Resins《热固性酚醛树脂冲击固化时间的测定的标准试验方法》.pdf
《ASTM D4640-1986(2009) Standard Test Method for Determining Stroke Cure Time of Thermosetting Phenol-Formaldehyde Resins《热固性酚醛树脂冲击固化时间的测定的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4640-1986(2009) Standard Test Method for Determining Stroke Cure Time of Thermosetting Phenol-Formaldehyde Resins《热固性酚醛树脂冲击固化时间的测定的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4640 86 (Reapproved 2009)Standard Test Method forDetermining Stroke Cure Time of Thermosetting Phenol-Formaldehyde Resins1This standard is issued under the fixed designation D4640; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the curerate at any specified temperature for a t
3、hermosetting phenol-formaldehyde resin. The time at that temperature required tomake a fluid mixture change into a hard immovable massindicates speed of cure.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI uni
4、ts that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine
5、the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions of Terms Specific to This Standard:2.1.1 stroke cure time, nthe time required for a resin beingheld at a specified temperature on a hot plate and being strokedwith a spatula, to adhere to the hot plate and not to
6、 the spatula.3. Summary of Test Method3.1 This test method employs the use of controlled heat anda thin layer of resin to determine the time in seconds requiredto change from a fluid stage to a cured immovable stage.4. Significance and Use4.1 This method is significant as a process control forpolyme
7、rization time.4.2 When the cure times are determined at several tempera-tures and plotted as time versus temperature, different resinscan be compared for curing characteristics.5. Apparatus5.1 Electric Hot Cure Plate, with a smooth surface free ofrough spots with adjustable control to hold the tempe
8、raturewithin 3.5F (2C) (Note 1).5.2 Spatula,3by716 in. (75 by 10 mm), stainless.5.3 Stopwatch.5.4 Knife, brass, putty with straight edge.6. Procedure6.1 Adjust the hot plate to the desired test temperature.NOTE 1Usual temperatures are 300F (150C), 320F (160C), and330F (165C).6.2 Place an approximate
9、ly 0.5-g specimen on the hot plateand spread over an approximately 2-in.2(130-mm2) area witha clean spatula as quickly as possible. Start the stopwatchimmediately upon adding the specimen to the hot plate, thenstroke steadily across the specimen in alternating smoothingand patting motions.6.3 As the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD464019862009STANDARDTESTMETHODFORDETERMININGSTROKECURETIMEOFTHERMOSETTINGPHENOLFORMALDEHYDERESINS

链接地址:http://www.mydoc123.com/p-517581.html