ASTM D4637 D4637M-2015 Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane《用于单层屋顶薄膜的EPDM薄板的标准规格》.pdf
《ASTM D4637 D4637M-2015 Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane《用于单层屋顶薄膜的EPDM薄板的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4637 D4637M-2015 Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane《用于单层屋顶薄膜的EPDM薄板的标准规格》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4637/D4637M 141D4637/D4637M 15Standard Specification forEPDM Sheet Used In Single-Ply Roof Membrane1This standard is issued under the fixed designation D4637/D4637M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1 NOTEEditorially corrected Table 1
3、 in July 2014.1. Scope1.1 This specification covers flexible sheet made from ethylene-propylene-diene terpolymer (EPDM) intended for use insingle-ply roofing membranes exposed to the weather. The tests and property limits used to characterize the sheet are values toensure minimum quality for the int
4、ended use. The sheet may be non-reinforced, fabric- or scrim-reinforced, or fabric-backedvulcanized rubber sheet.1.2 In-place roof system design criteria, such as fire resistance, field seaming strength, material compatibility, and upliftresistance, among others, are factors that must be considered
5、but are beyond the scope of this specification.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from
6、thetwo systems may result in non-conformance with the standard.1.4 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address allof the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to
7、establish appropriatesafety and health practices and determine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D412 Test Methods for Vulcanized Rubber and Thermoplastic ElastomersTensionD413 Test Methods for Rubber PropertyAdhesion to Flexible Subs
8、trateD471 Test Method for Rubber PropertyEffect of LiquidsD518 Test Method for Rubber DeteriorationSurface Cracking (Withdrawn 2007)3D573 Test Method for RubberDeterioration in an Air OvenD624 Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic ElastomersD751 Test Metho
9、ds for Coated FabricsD816 Test Methods for Rubber CementsD1149 Test Methods for Rubber DeteriorationCracking in an Ozone Controlled EnvironmentD1204 Test Method for Linear Dimensional Changes of Nonrigid Thermoplastic Sheeting or Film at Elevated TemperatureD2137 Test Methods for Rubber PropertyBrit
10、tleness Point of Flexible Polymers and Coated FabricsD5602D5602/D5602M Test Method for Static Puncture Resistance of Roofing Membrane SpecimensD5635D5635/D5635M Test Method for Dynamic Puncture Resistance of Roofing Membrane SpecimensD6382D6382/D6382M Practice for Dynamic Mechanical Analysis and The
11、rmogravimetry of Roofing and WaterproofingMembrane MaterialD7635/D7635M Test Method for Measurement of Thickness of Coatings Over Fabric ReinforcementG151 Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that Use Laboratory Light SourcesG155 Practice for Operating Xenon Arc Li
12、ght Apparatus for Exposure of Non-Metallic Materials1 This specification is under the jurisdiction of ASTM Committee D08 on Roofing and Waterproofing and is the direct responsibility of Subcommittee D08.18 onNonbituminous Organic Roof Coverings.Current edition approved May 1, 2014Nov. 1, 2015. Publi
13、shed June 2014December 2015. Originally approved in 1987. Last previous edition approved in 20132014 asD4637/D4637M 13.D4637/D4637M 141. DOI: 10.1520/D4637_D4637M-14E01.10.1520/D4637_D4637M-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at ser
14、viceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of
15、an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as publ
16、ished by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13. Classification3.1 Types describe the sheet construction:3.1.1 Type INon-reinforced.3.1.2 Type IIScrim (or fabric) internally re
17、inforced.3.1.3 Type IIIFabric backed.4. Materials and Manufacture4.1 The sheet shall be formulated from EPDM polymers and other compounding ingredients. EPDM shall be the principalpolymer used in the sheet and shall be greater than 95 % of the total polymer content.4.2 To make seams and repairs, the
18、 sheet shall be capable of being bonded watertight to itself and the supplier or fabricator shallrecommend suitable methods.5. Physical Properties and Tolerances5.1 The sheet shall conform to the physical requirements prescribed in Table 1.5.2 The tolerance for time conditions (aging, weathering, an
19、d so forth) is 615 min or 61 % of the period; whichever is greater,unless otherwise specified.5.3 Tolerances for temperature shall be 62C 64F.6. Dimensions6.1 The width and length of the sheet shall be agreed upon between the purchaser and the supplier.6.1.1 The width and length tolerance shall be +
20、3 %, 0 %.6.2 The thickness tolerance shall be +15 %, 10 % of the thickness agreed upon between the purchaser and supplier, but in nocase shall the thickness be less than the minimum listed in Table 1.TABLE 1 Physical Requirements for EPDM SheetType I II IIIThickness, min, mm in.:Sheet-overall 1.016
21、0.040 1.016 0.040 .Coating over scrim or fabric . 0.38 0.015 0.76 0.030Breaking strength, min, N lbf . 400 90 400 90Tensile strength, min, MPa psi 9.0 1305 . .Dynamic Puncture Resistance, Type I at 5 J, Type II at at 10 J pass passStatic Puncture Resistance, Type I at 20 kg 44.1 lbf, Type II at25 kg
22、 55.1 lbfpass passElongation, ultimate, min,% 300 250A 300AElongation fabric break, ultimate, min, %Machine directionCross direction1515Tensile set, max, % 10 . .Tear resistance, min, kN/m lbf/in. 26.27 150 . .Tearing strength, min, N lbf . 45 10 45 10Brittleness point, max, C F 45 49 45 49 45 49Ozo
23、ne resistance, no cracks pass pass passHeat aging:Breaking strength, min, N lbf . 356 80 356 80Tensile strength, min, MPa psi 8.3 1205 . .Elongation, ultimate, min,% 200 200A 200ATear resistance, min, kN/m lbf/in. 21.9 125 . .Linear dimensional change, max, % 1 1 1Water absorption, max, mass % + 8,
24、2 + 8, 2A + 8, 2A Water absorption, max, mass % + 8, 2 + 8, 2A + 8, 2AFactory seam strength, min, kN/m lbf/in. 8.8 50 or sheet failureWeather resistance:Visual inspection no cracks or crazing no cracks or crazing no cracks or crazingPRFSE, min, % 30 . .Elongation, ultimate, min, % 200 . .Fabric adhe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD4637D4637M2015STANDARDSPECIFICATIONFOREPDMSHEETUSEDINSINGLEPLYROOFMEMBRANE 用于 单层 屋顶 薄膜 EPDM 薄板 标准

链接地址:http://www.mydoc123.com/p-517573.html