ASTM D4637 D4637M-2012 Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane《单层屋顶防渗护面中使用的乙丙三元橡胶薄板标准规格》.pdf
《ASTM D4637 D4637M-2012 Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane《单层屋顶防渗护面中使用的乙丙三元橡胶薄板标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4637 D4637M-2012 Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane《单层屋顶防渗护面中使用的乙丙三元橡胶薄板标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4637/D4637M 12Standard Specification forEPDM Sheet Used In Single-Ply Roof Membrane1This standard is issued under the fixed designation D4637/D4637M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers flexible sheet mad
3、e fromethylene-propylene-diene terpolymer (EPDM) intended for usein single-ply roofing membranes exposed to the weather. Thetests and property limits used to characterize the sheet arevalues to ensure minimum quality for the intended use. Thesheet may be non-reinforced, fabric- or scrim-reinforced,
4、orfabric-backed vulcanized rubber sheet.1.2 In-place roof system design criteria, such as fire resis-tance, field seaming strength, material compatibility, and upliftresistance, among others, are factors that must be consideredbut are beyond the scope of this specification.1.3 The values stated in e
5、ither SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This stan
6、dard may involve hazardous materials, opera-tions, and equipment. This standard does not purport toaddress all of the safety concerns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicab
7、ility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D412 Test Methods for Vulcanized Rubber and Thermo-plastic ElastomersTensionD413 Test Methods for Rubber PropertyAdhesion toFlexible SubstrateD471 Test Method for Rubber PropertyEffect of LiquidsD518 Test Method
8、for Rubber DeteriorationSurfaceCracking3D573 Test Method for RubberDeterioration in an AirOvenD624 Test Method for Tear Strength of Conventional Vul-canized Rubber and Thermoplastic ElastomersD751 Test Methods for Coated FabricsD816 Test Methods for Rubber CementsD1149 Test Methods for Rubber Deteri
9、orationCrackingin an Ozone Controlled EnvironmentD1204 Test Method for Linear Dimensional Changes ofNonrigid Thermoplastic Sheeting or Film at ElevatedTemperatureD2137 Test Methods for Rubber PropertyBrittlenessPoint of Flexible Polymers and Coated FabricsD5602 Test Method for Static Puncture Resist
10、ance of Roof-ing Membrane SpecimensD5635 Test Method for Dynamic Puncture Resistance ofRoofing Membrane SpecimensD6382 Practice for Dynamic Mechanical Analysis andThermogravimetry of Roofing and Waterproofing Mem-brane MaterialD7635/D7635M Test Method for Measurement of Thick-ness of Coatings Over F
11、abric ReinforcementG151 Practice for Exposing Nonmetallic Materials in Ac-celerated Test Devices that Use Laboratory Light SourcesG155 Practice for Operating XenonArc LightApparatus forExposure of Non-Metallic Materials3. Classification3.1 Types describe the sheet construction:3.1.1 Type INon-reinfo
12、rced.3.1.2 Type IIScrim (or fabric) internally reinforced.3.1.3 Type IIIFabric backed.4. Materials and Manufacture4.1 The sheet shall be formulated from EPDM polymers andother compounding ingredients. EPDM shall be the principal1This specification is under the jurisdiction of ASTM Committee D08 onRo
13、ofing and Waterproofing and is the direct responsibility of Subcommittee D08.18on Nonbituminous Organic Roof Coverings.Current edition approved Jan. 1, 2012. Published January 2012. Originallyapproved in 1987. Last previous edition approved in 2010 as D4637 10. DOI:10.1520/D4637_D4637M-12.2For refer
14、enced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is re
15、ferencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.polymer used in the sheet and shall be greater than 95 % of thetotal polymer content.4.2 To make seams and repairs, the sheet shall be capable ofbeing bonded wat
16、ertight to itself and the supplier or fabricatorshall recommend suitable methods.5. Physical Properties and Tolerances5.1 The sheet shall conform to the physical requirementsprescribed in Table 1.5.2 The tolerance for time conditions (aging, weathering,and so forth) is 615 min or 61 % of the period;
17、 whichever isgreater, unless otherwise specified.5.3 Tolerances for temperature shall be 62C 64F.6. Dimensions6.1 The width and length of the sheet shall be agreed uponbetween the purchaser and the supplier.6.1.1 The width and length tolerance shall be +3 %, 0 %.6.2 The thickness tolerance shall be
18、+15 %, 10 % of thethickness agreed upon between the purchaser and supplier, butin no case shall the thickness be less than the minimum listedin Table 1.7. Workmanship, Finish, and Appearance7.1 The sheet, including the full width of factory seams ifpresent, shall be fully adhered, watertight, and vi
19、sibly free ofpinholes, particles of foreign matter, undispersed raw material,or other manufacturing defects that might affect serviceability.If the number of irregularities in the form of pockmarks (seeNote 1) appear excessive on the sheet (or portion thereof), thenits rejection shall be negotiated
20、between involved parties.7.2 Edges of the sheets shall be straight and flat so that theymay be seamed to one another without fishmouthing.NOTE 1Pockmarks are oblong depressions, cavities, or craters on thesurface of the sheet that have an approximate surface dimension of 3.2 by1.6 mm 18 by116 in., a
21、nd have a maximum depth approaching one halfof the sheet thickness.8. Test Methods8.1 DimensionsTest Methods D751, after permitting thesheet to relax at 23 6 2C 73.4 6 4F for 1 h 6 15 min.8.2 Thickness, Sheet OverallFrom across the full width ofthe unbuffed sheet, take three samples, 300 by 300 mm 1
22、 by1 ft. Measure the thickness of each corner. On fabric backed(Type III) the coating thickness can be measured after cuttingor buffing fabric from the rubber. Refer to Test Method D412for Type I sheet and Test Method D751 for Type II and Type IIIsheet.8.3 Thickness of Coating Over Scrim (Reinforcin
23、gFabric)Follow preparation procedures as specified in TestMethod D7635/D7635M. The thickness measurements shall beconducted as described in the test method on the coating on theside intended to be exposed to the weather.8.4 Breaking StrengthTest Methods D751, Grab Method.8.5 Tensile StrengthTest Met
24、hods D412, Die C.8.6 Dynamic Puncture ResistanceTest Method D5635,atan energy of 5 J min at 23 6 2C 73.4 6 4F for Type I andan energy of 10 J min for Type II.8.7 Static Puncture ResistanceTest Method D5602,ataload of 20 kg 44.1 lbf min for Type I and a load of 25 kg 55.1lbf min for Type II at 23 6 2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD4637D4637M2012STANDARDSPECIFICATIONFOREPDMSHEETUSEDINSINGLEPLYROOFMEMBRANE 单层 屋顶 防渗 护面中 使用 三元 橡胶

链接地址:http://www.mydoc123.com/p-517569.html