1、Designation: D4596 09 (Reapproved 2015)Standard Practice forCollection of Channel Samples of Coal in a Mine1This standard is issued under the fixed designation D4596; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes procedures for collecting a coalsample from a channel extending from top to bottom in the faceof a
3、 coal seam in a mine.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this stand
4、ard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary information, see Note 2.2. Referenced Documents2.1 ASTM Standards:2D121 Terminology of Coal and CokeD388 Classification of Coals by RankD2234/D
5、2234M Practice for Collection of a Gross Sampleof CoalD2796 Terminology for Megascopic Description of Coaland Coal Seams and Microscopical Description andAnalysis of Coal (Withdrawn 1995)3D4371 Test Method for Determining the Washability Char-acteristics of Coal3. Summary of Practice3.1 At selected
6、sites in the mine the face of the seam iscleaned of weathered coal and debris and the face is evened. Achannel of uniform horizontal cross section is cut from the coalseam and the coal therefrom is collected for analysis andtesting.4. Significance and Use4.1 A properly collected face channel sample
7、that includesthe total coal bed interval provides a sample that is a repre-sentative cross section of the coal bed at the point of sampling.Channel samples are taken for subsequent testing needed forevaluation of coal quality and characterization for commercialevaluations, for planning of mining ope
8、rations to maintain coalquality, for the determination of coal rank in accordance withClassification D388, and for geologic coal resource studies.NOTE 1Because of the potential for lateral variability, a sample maynot represent the quality of the coal bed at another sample point. Thereliability of t
9、he data generated from channel samples is dependent on thenumber and spacing of the sample points and the variability of the coalcharacteristics in a given area.NOTE 2Sampling of the mine product for these purposes is unsatis-factory because of contamination of the product with out-of-seammaterial,
10、selective mining of parts of a seam, inability to obtain samplesfrom one or more specific locations in the mine, or other incompatibilityof the purpose of sampling with the mining practice. Conversely, channelsamples should not be used for evaluation of the quality of commercialshipments of the mine
11、 product, which should be sampled in accordancewith Methods D2234/D2234M.5. Apparatus5.1 Steel Measuring Tape, not less than3m(8ft)long.5.2 Miners Pick or Similar Tool, with file for sharpening.Other devices may be used such as a pneumatically operatedchain saw with tungsten carbide teeth.5.3 Brush
12、or Broom, for removing loose particles on thecoal face.5.4 Chalk.5.5 Sample Containers With ClosuresIf the sample is to beused for determination of inherent moisture, the container shallbe such that less than 0.05 % of the sample weight is lostbetween the time of sealing the container with sample an
13、d thetime of opening for preparation of the sample for analysis.Steel airtight containers with polyethylene bag liners have been1This practice is under the jurisdiction of ASTM Committee D05 on Coal andCoke and is the direct responsibility of Subcommittee D05.18 on Classification ofCoals.Current edi
14、tion approved Sept. 1, 2015. Published September 2015. Originallypublished approved in 1986. Last previous edition approved in 2009 as D4596 09.DOI: 10.1520/D4596-09R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annua
15、l Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United S
16、tates1found to be satisfactory for this purpose. For other purposes,bags made of a strong cloth and lined with a polyethylene bagmay be suitable.5.6 Ground ClothCanvas tarpaulin or heavy-duty plasticsheet about 3 by 3 m (10 by 10 ft). If the purpose of samplingincludes the determination of inherent
17、moisture, the sheet shallbe of low water solubility and permeability, such as polyeth-ylene or oilcloth.5.7 Tags and Pen, for sample identification and for marking.5.8 Shovel.5.9 Notebook and Pencil, or other means for record keeping.6. Planning of Sampling6.1 Considerations regarding weathered coal
18、 and inherentmoisture:Weathered coal is unsuitable for inclusion in channel samplescollected to secure fresh and unaltered material. Weatheredcoal typically contains anomalously low total moisture, yieldslow calorific value (dry and moisture-and-ash-free basis), andalso produces atypical results for
19、 other tests. It does not reflectunaltered in-situ coal properties, cannot be used for classifica-tion according to rank, and does not give accurate estimates oftypical as-mined moisture.6.1.1 Obvious indications of weathering include, but are notlimited to: (1) any discoloration of broken coal surf
20、aces orcleats, (2) presence of sulfate minerals resulting from oxidationof pyrite, (3) presence of gypsum (calcium sulfate) crystals,and (4) presence of dust, cracked and crazed coal surfaces, ora fragmented condition of the coal blocks resulting from loss ofinherent moisture.6.1.2 It is often usefu
21、l to collect samples containing theirfull complement of inherent moisture, but that condition maynot always be readily discernable. A simple field test can beused to qualitatively identify seemingly fresh coal that has lostsome inherent moisture but has not yet obviously weathered. Alight coating of
22、 water is sprayed or wiped onto the surface ofthe coal, and the rate at which it disappears is observed. Rapiddisappearance (typically within a few seconds) indicates ab-sorption and demonstrates that the coal contains less than itsfull compliment of inherent moisture. Slower disappearance(taking pe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD459620092015STANDARDPRACTICEFORCOLLECTIONOFCHANNELSAMPLESOFCOALINAMINE 收集 矿井 通道 样本 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-517463.html