《ASTM D4590-2018 Standard Test Method for Colorimetric Determination of p-tert-Butylcatechol In Styrene Monomer or AMS (&x3b1 &x2013 Methylstyrene) by Spectrophotometry.pdf》由会员分享,可在线阅读,更多相关《ASTM D4590-2018 Standard Test Method for Colorimetric Determination of p-tert-Butylcatechol In Styrene Monomer or AMS (&x3b1 &x2013 Methylstyrene) by Spectrophotometry.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4590 13D4590 18Standard Test Method forColorimetric Determination of p-tert-Butylcatechol In StyreneMonomer or AMS (Methylstyrene) by Spectrophotometry1This standard is issued under the fixed designation D4590; the number immediately following the designation indicates the year oforigi
2、nal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method is applicable to the determination of residual
3、 4-tertiary-butylcatechol (TBC) in styrene monomer or AMSin the 1 to 100 mg/kg range. Any other compound producing color at 490 nm when contacted with aqueous sodium hydroxidesolution will interfere. It may be compensated for by including it in the preparation of the standard solutions, if its ident
4、ity andconcentration in the sample are known.1.2 In determining the conformance of the test results using this method to applicable specifications, results shall be roundedoff in accordance with the rounding-off method of Practice E29. The limit of detection is 0.2 mg/kg while the limit of quantitat
5、ionis 0.8 mg/kg based on the ILS data in Table 1.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsi
6、bilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use. For specific statements on hazards, see Section 8.1.5 This international standard was developed in accordance wi
7、th internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:
8、2D1193 Specification for Reagent WaterD3437 Practice for Sampling and Handling Liquid Cyclic ProductsD4790 Terminology of Aromatic Hydrocarbons and Related ChemicalsD6809 Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related MaterialsE29 Practice for Using
9、Significant Digits in Test Data to Determine Conformance with SpecificationsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method2.2 Other Document:OSHA Regulations, 29 CFR paragraphs 1910.1000 and 1910.1200 33. Terminology3.1 See Terminology D4790 for def
10、inition of terms used in this standard.4. Summary of Method4.1 Color is developed in the specimen by the addition of caustic in a methanol-octanol solvent. The intensity of the pink coloris measured with a spectrometer and compared to a calibration curve for quantitation.1 This test method is under
11、the jurisdiction of ASTM Committee D16 on Aromatic Hydrocarbons Aromatic, Industrial, Specialty and Related Chemicals and is the directresponsibility of Subcommittee D16.07 on Styrene, Ethylbenzene and C9 and C10 Aromatic Hydrocarbons.Current edition approved June 1, 2013June 1, 2018. Published June
12、 2013June 2018. Originally approved in 1986. Last previous edition approved in 20092013 asD4590 09.D4590 13. DOI: 10.1520/D4590-13.10.1520/D4590-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standar
13、dsvolume information, refer to the standardsstandards Document Summary page on the ASTM website.3 Available from U.S. Government Printing Office Superintendent of Documents, 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.This document is not an ASTM standard a
14、nd is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only
15、 the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance and Us
16、e5.1 This test method is suitable for determining the quantity of TBC inhibitor, both for the protection against polymerizationwhile in transit and storage, and for internal quality control.6. Apparatus6.1 Visible Range Spectrometer, equipped with absorption cells providing light paths from 1 to 5 c
17、m for use at approximately490 nm.6.2 Volumetric Pipets and PipetorsThe sample pipet volume should be sized to fill the spectrometer absorption cell. Pipetorvolumes must be scaled to the sample volume. This procedure is written using a 15 mLsample volume. The following table showshow reagent pipetor
18、volumes could be scaled to use a 5 mL sample volume.TABLE 1 Intermediate Precision and ReproducibilityTBC ObservedConcentration Repeatability Reproducibility4.7 0.23 0.9415.2 0.47 5.0824.5 1.55 4.9194.6 3.98 9.94D4590 182Sample Pipet,mL0.15 NaOHPipetor,LMethanol Pipetor,L15 300 6005 100 2007. Reagen
19、ts and Materials7.1 Purity of ReagentsReagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that allreagents shall conform to the specification of the Committee onAnalytical Reagents of theAmerican Chemical Society, where suchspecifications are available.4 Ot
20、her grades may be used, provided it is first ascertained that the reagent is of sufficiently high purityto permit its use without lessening the accuracy of the determination.7.2 4-Tertiary-Butylcatechol, Mp 52 to 55C.7.3 Toluene, ACS reagent grade.7.4 Methanol, reagent grade.7.5 n-Octanol, reagent g
21、rade.7.6 Aqueous Sodium Hydroxide, 10 Normal (10N), reagent grade.7.7 Alcoholic Sodium Hydroxide, approximately 0.15 N: Mix 0.75 mL of 10N Aqueous Sodium Hydroxide with 25 mLmethanol. With stirring, add 25 mLof n-octanol and then 0.75 mLof water. Store the reagent in an amber glass bottle. This reag
22、entcan be used immediately after preparation and is stable for at least 2 months. To reduce exposure of the reagent to the atmosphere,transfer enough for several samples to a small clean vial.7.8 TBC Stock StandardThis standard may be purchased if desired. Prepare a stock solution by weighing 0.500
23、6 0.001 gof TBC to the nearest 0.0001 g into 500 6 1 g of toluene (weighed to the nearest 0.1 g). This solution will have a concentrationof approximately 1000 mg/kg TBC in toluene and the exact concentration can be calculated using Eq 1. This standard should havea shelf life of one year or better if
24、 stored in a refrigerator or freezer. Storing standards in amber bottles significantly reducesdegradation of standards with time.mg TBC/kg toluene5g of TBC! 3Purity of TBC! 3106!#/g of toluene (1)7.9 Purity of WaterUnless otherwise indicated, references to water shall be understood to mean any reage
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD45902018STANDARDTESTMETHODFORCOLORIMETRICDETERMINATIONOFPTERTBUTYLCATECHOLINSTYRENEMONOMERORAMSX3B1X2013METHYLSTYRENEBYSPECTROPHOTOMETRYPDF

链接地址:http://www.mydoc123.com/p-517446.html