ASTM D4512-2003(2018)e1 Standard Test Method for Vibrated Apparent Packing Density of Fine Catalyst and Catalyst Carrier Particles and Powder.pdf
《ASTM D4512-2003(2018)e1 Standard Test Method for Vibrated Apparent Packing Density of Fine Catalyst and Catalyst Carrier Particles and Powder.pdf》由会员分享,可在线阅读,更多相关《ASTM D4512-2003(2018)e1 Standard Test Method for Vibrated Apparent Packing Density of Fine Catalyst and Catalyst Carrier Particles and Powder.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4512 03 (Reapproved 2018)1Standard Test Method forVibrated Apparent Packing Density of Fine Catalyst andCatalyst Carrier Particles and Powder1This standard is issued under the fixed designation D4512; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTESection 6.5 was updated editorially in May 2018.1. Scope1.1 This test method cove
3、rs the determination of the appar-ent packing density of fine catalyst and catalyst carrier powderssmaller than 0.8 mm in diameter.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address
4、 all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This international standard was develope
5、d in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documen
6、ts2.1 ASTM Standards:2D3766 Terminology Relating to Catalysts and CatalysisE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE456 Terminology Relating to Quality and StatisticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Te
7、rminology3.1 DefinitionsSee Terminology D3766.4. Significance and Use4.1 This test method is for measuring the apparent packingdensity of catalyst or catalyst carrier powders that are smallerthan 0.8 mm in diameter.5. Apparatus5.1 Glass Cylinders, capacity 100 mL, feed and measuring.5.2 Vibrator,3co
8、nventional hand-held, with hard rubber ormetal impactor.5.3 Feed Funnel, plastic, glass, or metal as shown in Fig. 1.5.4 Ring Stand, vibrator holder and clamps as shown inFigs. 2 and 3.5.5 Desiccator, with a desiccant grade molecular sieve suchas 4A.5.6 Balance, having sensitivity of 0.1 g.5.7 Dryin
9、g Oven.6. Procedure6.1 Heat an adequate amount of sample(s) at 400 6 15Cfor not less than 3 h. Normally, this treatment can take place inair; however, in the case of materials that might react with airat elevated temperatures (such as, prereduced catalysts) theheat treatment shall take place in an i
10、nert atmosphere. Afterheating, cool the test sample(s) in a desiccator or other suitablecontainer to eliminate the possibility of moisture adsorptionprior to testing.NOTE 1These conditions may not be appropriate for all materials.NOTE 2Since many catalyst formulations are strong adsorbents, theuse o
11、f 4A indicating (cobalt-treated) molecular sieve as a desiccatingmedium is suggested. The desiccant should be regenerated at 493 K(220C) to 533 K (260C), as required.1This test method is under the jurisdiction of ASTM Committee D32 onCatalysts and is the direct responsibility of Subcommittee D32.02
12、on Physical-Mechanical Properties.Current edition approved May 1, 2018. Published June 2018. Originallyapproved in 1985. Last previous edition approved in 2013 as D451203(2013).DOI: 10.1520/D4512-03R18E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer S
13、ervice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The sole source of supply of the vibrator known to the committee at this timeis Wahl Clipper Corp., Sterling, IL. They recommend their Model 4120 used at l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD451220032018E1STANDARDTESTMETHODFORVIBRATEDAPPARENTPACKINGDENSITYOFFINECATALYSTANDCATALYSTCARRIERPARTICLESANDPOWDERPDF

链接地址:http://www.mydoc123.com/p-517256.html